Home›Magnum›Magnum MMG75

Magnum MMG75 Generator Set

The Magnum MMG75 is a 60 kW (60 kVA) diesel standby generator set powered by a John Deere PE4045HFG92 engine. It is available at 120/240 V, 120/208 V and 277/480 V, single-phase and 60 Hz. It holds about 15.5 L (4.1 gal) of oil and 4.5 L (1.2 gal) of coolant, with a maximum ambient rating of 48.9 °C. Starting uses 1 battery rated 720 CCA. The set measures 2565×1016×1727 mm (101.0×40.0×68.0 in), weighs about 1600 kg (3527 lb) and produces 68 dBA at 7.01 m. An integrated tank holds 624.1 L (164.9 gal), roughly 31 hours of runtime. The same PE4045HFG92 engine also powers generator sets from Generac.

60 kW
Standby
4.5 L
Displacement
15.5 L
Oil capacity
3
Document types

Typical fuel consumption for 60–65 kW Diesel generators →

Compare with other 60–65 kW Diesel generators →

Service parts for the MMG75

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
25-1476Air filtersee priceAmazon

Fuel system

1 required
25-1639Fuel filtersee priceAmazon

Oil system

1 required
25-1648Oil filtersee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power60 kW
Standby kVA60
Prime power56 kW
EmissionsInterim Tier IV
ControllerMagnum Digital (MDC), Power Zone
Oil capacity15.5 L
AlternatorMarathon 363PSL1607 (1661) (Class H insulation)
Voltage options120/240 V, 120/208 V, 277/480 V
Phasesingle/three
Circuit breaker300 A
Battery cranking720 CCA
Battery quantity1
Max ambient48.9 °C
Dimensions (L×W×H)2565×1016×1727 mm
Dry weight1600 kg
Wet weight2131 kg
Sound level68.0 dBA @ 7.01 m
Fuel tank624.1 L
Tank runtime31 hr

Engine

John Deere PE4045HFG92
Oil capacity14.7 L
Coolant capacity4.5 L
Displacement4.5 L
Aspirationturbocharged
Rated speed1800 rpm

Maintenance & consumables

for the John Deere PE4045HFG92
ItemSpecCapacityPart #Interval
Air filterAir Filter Minders25-1476 Amazon eBay
Fuel filterFuel Filters25-1639 Amazon eBay
Oil filterOil Filters25-1648 Amazon eBay
Battery—250 hr
Belt—500 hr
Coolant20.8—1000 hr
Coolant filter—
Oil15.5—300 hr
Spark plug—1000 hr

Service specifications

6
TypeItemValueUnitCondition
PressureOil pressure20psishutdown threshold
PressureOil pressure25psiwarning threshold
TemperatureCoolant temperature220°Fwarning threshold
TemperatureCoolant temperature230°Fshutdown threshold
VoltageBattery voltage11VDCunder warning
VoltageBattery voltage15VDCover warning

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the Magnum MMG75?

The Magnum MMG75 is rated 60 kW standby (60.0 kVA).

Which engine powers the Magnum MMG75?

The Magnum MMG75 is powered by the John Deere PE4045HFG92 engine.

What fuel does the Magnum MMG75 use?

The Magnum MMG75 runs on diesel.

What is the oil capacity of the Magnum MMG75?

The John Deere PE4045HFG92 engine in the Magnum MMG75 has an oil capacity of 14.7 liters.

What is the cooling system capacity of the Magnum MMG75?

The Magnum MMG75 cooling system holds 4.5 liters (1.2 US gallons) for the engine, per the manufacturer specification sheet.

What is the continuous rating of the Magnum MMG75?

The Magnum MMG75 is rated 56 kW prime (56 kVA), against 60 kW standby.

What is the sound level of the Magnum MMG75?

The Magnum MMG75 is rated at 68.0 dBA at 7.01 m, per the manufacturer specification sheet.

How much does the Magnum MMG75 weigh?

The Magnum MMG75 has a dry weight of 1600 kg (3527 lb).

What size fuel tank does the Magnum MMG75 have?

The Magnum MMG75 has a 624.1 liter (165 US gallon) fuel tank, giving about 31 hours of runtime.

What voltages is the Magnum MMG75 available in?

The Magnum MMG75 is offered in 120/240 V, 120/208 V, 277/480 V, single/three-phase.

How many cold cranking amps does the Magnum MMG75 require?

The Magnum MMG75 uses 1 battery, 720 CCA, per the manufacturer specification sheet.

What alternator comes on the Magnum MMG75?

The Magnum MMG75 uses a Marathon 363PSL1607 (1661) alternator. Insulation class H.

What oil filter fits the Magnum MMG75?

The Magnum MMG75 uses oil filter part number 25-1648.

What fuel filter fits the Magnum MMG75?

The Magnum MMG75 uses fuel filter part number 25-1639.

What air filter does the Magnum MMG75 use?

The Magnum MMG75 uses air filter part number 25-1476.

Troubleshooting

34

Fault codes

CodeMeaningRemedy
SPN:100EngOil Press
SPN:102Boost Press
SPN:105Intake Temp
SPN:110EngCool Temp
SPN:175EngOil Temp
SPN:629Controller #1
SPN:636PositionSensor
SPN:637TimingSensor
SPN:651InjectorCyl#1
SPN:652InjectorCyl#2
SPN:653InjectorCyl#3
SPN:654InjectorCyl#4
SPN:655InjectorCyl#5
SPN:656InjectorCyl#6
SPN:677EngStartRelay
SPN:1485ECU MainRelay
WrnMaintenanceWrnMaintenance — The period for servicing is set by the WrnMaintenance setpoint. The protection comes active if the running hours of the engine reach this value.Reset the running hours to 250: with the unit shut down, power up the controller with the CONTROL ON/OFF toggle switch; press the PAGE SELECT button; press the down button to move the > cursor down to the Engine Protect line of text; press ENTER; press ENTER again; press the up button and reset the current run time hour setting to 250; press ENTER to save the current run time hour setting; move the CONTROL ON/I toggle switch to the CONTROL OFF/O position
Wrn ECU AlarmWrn ECU Alarm — ECU alarm list is not empty.
Wrn RA15 failWrn RA15 fail — Warning alarm in case of lost connection to IGL=RA15 module.

Symptoms & remedies

SymptomCauseRemedy
Low fuel level shutdownFuel level low; fuel tank leaks; fuel level sender or connecting wiring damagedCheck the fuel level on the LCD window and confirm the generator is sitting level; check for leaks in the fuel tank; check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller
Low oil pressure shutdownEngine oil level low; oil leaks; loss of oil pressure; oil pressure sender faultyCheck the level of the engine oil with the dipstick and add oil if required; visually inspect the engine for oil leaks; restart the unit and verify the loss of oil pressure, shutting the engine down immediately if the oil pressure value does not read five (5) psi (34 kPa) within five (5) seconds; check the oil pressure sender and refer to the troubleshooting section of the engine operation and maintenance manual
Low coolant level shutdownCoolant level low; coolant leaks in hoses, engine block or water pump; coolant mixed with engine oilAllow the engine to cool; check the coolant level in the radiator and add coolant until it is 3/4 in (2 cm) below the filler neck, then secure the radiator cap; inspect coolant hoses, engine block and water pump for visible leaks; check the engine oil to verify no coolant has mixed with it and consult the engine operation and maintenance manual
High coolant temperature shutdownCoolant level low in overflow jug; radiator shroud and ducting blocked; coolant leaks in hoses, engine block or water pump; serpentine drive belt for the water pump loose; engine overheatingCheck the coolant level in the overflow jug; restart the engine and read the coolant temperature to verify High Coolant Temperature Shutdown, stopping the engine immediately if the coolant temperature is 230°F (110°C) or more; allow the engine to cool, add coolant to the overflow jug if low and check the radiator level, adding coolant until it is 3/4 in (2 cm) below the filler neck and securing the radiator cap; check the radiator shroud and ducting for blockage and remove any foreign matter; inspect coolant hoses, engine block and water pump for visible leaks; check the tension of the serpentine drive belt for the water pump; if no other problems are found, remove the load on the generator and restart the engine, checking the coolant temperature and shutting the engine down immediately if it starts to overheat, and consult the engine operation and maintenance manual
Overcrank shutdownFuel level low; fuel pump not operating properly; air filter blocked; engine will not startCheck the fuel level in the tank; check for proper operation of the fuel pump; check air filter for blockage; if the engine will not start, consult the engine operation and maintenance manual for additional information on troubleshooting starting problems
Overspeed or underspeed shutdownFrequency above or below 60.0 Hz with no loads on the generator (engine speed requires adjustment)Disconnect all loads and restart the generator, read the frequency (Hz) on the LCD display (should read 60.0 Hz with no loads); if the frequency is above or below 60.0 Hz, adjust the engine speed — see the engine manual for throttle adjustments on mechanical governed units and the electronic governor manual for electronically controlled units
Low fuel level shutdownFuel level low; leaks in the fuel tank; fuel level sender and connecting wiring damagedCheck the fuel level on the Home screen and confirm the generator is sitting level; check for leaks in the fuel tank; check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller
Low coolant level shutdownCoolant level low; leaks in coolant hoses, engine block or water pump; coolant mixed with engine oilAllow the engine to cool; check the coolant level in the radiator and add coolant until it is 3/4 in. (1.9 cm) below the filler neck; inspect coolant hoses, engine block and water pump for visible leaks; check engine oil to verify no coolant has mixed with it and consult the engine operator's manual
High coolant temperature shutdownCoolant level low in overflow jug or radiator; radiator shroud and ducting blocked; leaks in coolant hoses, engine block or water pump; serpentine drive belt tension incorrect; generator overloadedCheck the coolant level in the overflow jug; restart the engine and read the coolant temperature, stopping the engine immediately if the coolant temperature is 230°F (110°C) or more; allow the engine to cool, add coolant to the overflow jug if low and check the radiator level, adding coolant until it is 3/4 in. (1.9 cm) below the filler neck; check the radiator shroud and ducting for blockage and remove any foreign matter; inspect coolant hoses, engine block and water pump for visible leaks; check the tension of the serpentine drive belt for the water pump; remove the load on the generator and restart the engine, checking the coolant temperature and shutting the engine down immediately if it starts to overheat
Overspeed or underspeed shutdownEngine speed above or below 60.0 HzDisconnect all loads and restart the generator and read the frequency (Hz) on the LCD display; if the frequency is above or below 60.0 Hz, adjust the engine speed per the engine operator's manual for throttle adjustments on mechanically governed units and the electronic governor manual for electronically controlled units
Low fuel level shutdownFuel level low; fuel tank leak; fuel level sender or connecting wiring damagedCheck the fuel level on the LCD window and confirm the generator is sitting level; check for leaks in the fuel tank; check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller
Low oil pressure shutdownEngine oil level low; oil leaks; loss of oil pressure; oil sender faultCheck the level of the engine oil with the dipstick and add oil if required; visually inspect the engine for oil leaks; restart the unit and verify the loss of oil pressure, shutting the engine down immediately if the oil pressure value does not read 5 psi (34 kPa) within five seconds; check the oil sender and refer to the troubleshooting section of the engine operator's manual
Low coolant level shutdownCoolant level low; coolant leaks; coolant mixed with engine oilAllow the engine to cool; check the coolant level in the radiator and add coolant until it is 3/4 in. (1.9 cm) below the filler neck; inspect coolant hoses, engine block and water pump for visible leaks; check the engine oil to verify no coolant has mixed with it and consult the engine operator's manual
High coolant temperature shutdownCoolant level low; radiator shroud and ducting blockage; coolant leaks; loose serpentine drive belt for the water pump; engine overheatingCheck the coolant level in the overflow jug; restart the engine and read the coolant temperature to verify a high coolant temperature shutdown, stopping the engine immediately if the coolant temperature is 230°F (110°C) or more; allow the engine to cool, add coolant to the overflow jug if it is low and check the level of coolant in the radiator, adding coolant until it is 3/4 in. (1.9 cm) below the filler neck; check the radiator shroud and ducting for blockage and remove any foreign matter; inspect coolant hoses, engine block and water pump for visible leaks; check the tension of the serpentine drive belt for the water pump; if no other problems are found, remove the load on the generator and restart the engine, checking the coolant temperature and shutting the engine down immediately if it starts to overheat, and consult the engine operator's manual
Overspeed or underspeed shutdownEngine speed not adjusted (frequency above or below 60.0 Hz)Disconnect all loads and restart the generator and read the frequency (Hz) on the LCD display (with no loads the frequency should read 60.0 Hz); if the frequency is above or below 60.0 Hz, adjust the engine speed per the engine operator's manual for throttle adjustments on mechanical governed units and the electronic governor manual for electronically controlled units

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

11
Part #DescriptionQtySystem
100-025Air Filter1Air filter Amazon eBay
100-030Oil Filter1Oil filter Amazon eBay
100-045Fuel Filter1Fuel filter Amazon eBay FridayParts $20.19
100-060Coolant Filter1Coolant filter Amazon eBay
100-085Belt2Belt Amazon eBay
100-100Spark Plug1Spark plug Amazon eBay
25-1476Air Filter Minders1Air filter Amazon eBay
25-1483Primary Air Cleaners1Air filter Amazon eBay
25-1639Fuel Filters1Fuel filter Amazon eBay
25-1648Oil Filters1Oil filter Amazon eBay
AN500T0106STARTER SWITCHStarter Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime23.56.2
Prime50%9.82.6
Prime75%14.23.74
Prime100%18.14.78
Standby18.14.78
Standby100%18.14.78

Available documents

Spec sheet (Magnum)Spec sheet — MMG75-SPECS (Magnum)Reference — MMG75D-100D-Ops-03-15-13-32668-B (Magnum)Service manual — 32668 (Magnum)

This page was generated from the 4 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Other sets with this engine