Magnum MMG100D Generator Set

The Magnum MMG100D is a 86 kW (107 kVA) Diesel standby generator set. It is available at 120/240 V, 120/208 V and 277/480 V, 3-phase and 60 Hz. It holds about 15.5 L (4.1 gal) of oil, with a maximum ambient rating of 48.9 °C. Starting uses 1 battery rated 720 CCA. The set measures 3022×1022×1572 mm (119.0×40.2×61.9 in), weighs about 1714 kg (3779 lb) and produces 68 dBA at 7 m. An integrated tank holds 624.8 L (165.1 gal), roughly 24 hours of runtime.

86 kW
Standby
15.5 L
Oil capacity
3
Document types

Typical fuel consumption for 85–90 kW Diesel generators →

Compare with other 85–90 kW Diesel generators →

Service parts for the MMG100D

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
100-025Air filtersee priceAmazon

Fuel system

1 required
100-045Fuel filtersee priceAmazon

Oil system

1 required
100-030Oil filtersee priceAmazon

Belts

1 required

Cooling system

1 required
100-060Coolant filtersee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power86 kW
Standby kVA107
Prime power78 kW
EmissionsInterim Tier IV
ControllerPower Zone
Oil capacity15.5 L
AlternatorMarathon 363PSL1607 (1661) (Class H insulation)
Voltage options120/240 V, 120/208 V, 277/480 V
Phase3
Circuit breaker400 A
Battery cranking720 CCA
Battery quantity1
Max ambient48.9 °C
Dimensions (L×W×H)3022×1022×1572 mm
Dry weight1714 kg
Wet weight2150 kg
Sound level68.0 dBA @ 7 m
Fuel tank624.8 L
Tank runtime24 hr

Maintenance & consumables

ItemSpecCapacityPart #Interval
Air filterAir Filter100-025 Amazon eBay
Fuel filterFuel Filter100-045 Amazon eBay FridayParts $20.19
Oil filterOil Filter100-030 Amazon eBay
BeltBelt100-085 Amazon eBay
Coolant filterCoolant Filter100-060 Amazon eBay

Common questions

What is the power rating of the Magnum MMG100D?

The Magnum MMG100D is rated 86 kW standby (107.0 kVA).

What kind of fuel does the Magnum MMG100D run on?

The Magnum MMG100D runs on Diesel.

How much oil does the Magnum MMG100D take?

The Magnum MMG100D has an engine oil capacity of 15.5 liters (16.4 US quarts), per the manufacturer specification sheet.

What is the prime power rating of the Magnum MMG100D?

The Magnum MMG100D is rated 78 kW prime (98 kVA), against 86 kW standby.

What is the sound level of the Magnum MMG100D?

The Magnum MMG100D is rated at 68.0 dBA at 7 m, per the manufacturer specification sheet.

What is the dry weight of the Magnum MMG100D?

The Magnum MMG100D has a dry weight of 1714 kg (3778 lb).

How big is the fuel tank on the Magnum MMG100D?

The Magnum MMG100D has a 624.8 liter (165 US gallon) fuel tank, giving about 24 hours of runtime.

What voltages is the Magnum MMG100D available in?

The Magnum MMG100D is offered in 120/240 V, 120/208 V, 277/480 V, 3-phase.

What size battery does the Magnum MMG100D need?

The Magnum MMG100D uses 1 battery, 720 CCA, per the manufacturer specification sheet.

What alternator does the Magnum MMG100D use?

The Magnum MMG100D uses a Marathon 363PSL1607 (1661) alternator. Insulation class H.

What oil filter does the Magnum MMG100D use?

The Magnum MMG100D uses oil filter part number 100-030.

What fuel filter fits the Magnum MMG100D?

The Magnum MMG100D uses fuel filter part number 100-045.

Which air filter part number does the Magnum MMG100D take?

The Magnum MMG100D uses air filter part number 100-025.

Troubleshooting

10

Symptoms & remedies

SymptomCauseRemedy
Low fuel level shutdownFuel level low; fuel tank leaks; fuel level sender or connecting wiring damagedCheck the fuel level on the LCD window and confirm the generator is sitting level; check for leaks in the fuel tank; check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller
Low oil pressure shutdownEngine oil level low; oil leaks; loss of oil pressure; oil pressure sender faultyCheck the level of the engine oil with the dipstick and add oil if required; visually inspect the engine for oil leaks; restart the unit and verify the loss of oil pressure, shutting the engine down immediately if the oil pressure value does not read five (5) psi (34 kPa) within five (5) seconds; check the oil pressure sender and refer to the troubleshooting section of the engine operation and maintenance manual
Low coolant level shutdownCoolant level low; coolant leaks in hoses, engine block or water pump; coolant mixed with engine oilAllow the engine to cool; check the coolant level in the radiator and add coolant until it is 3/4 in (2 cm) below the filler neck, then secure the radiator cap; inspect coolant hoses, engine block and water pump for visible leaks; check the engine oil to verify no coolant has mixed with it and consult the engine operation and maintenance manual
High coolant temperature shutdownCoolant level low in overflow jug; radiator shroud and ducting blocked; coolant leaks in hoses, engine block or water pump; serpentine drive belt for the water pump loose; engine overheatingCheck the coolant level in the overflow jug; restart the engine and read the coolant temperature to verify High Coolant Temperature Shutdown, stopping the engine immediately if the coolant temperature is 230°F (110°C) or more; allow the engine to cool, add coolant to the overflow jug if low and check the radiator level, adding coolant until it is 3/4 in (2 cm) below the filler neck and securing the radiator cap; check the radiator shroud and ducting for blockage and remove any foreign matter; inspect coolant hoses, engine block and water pump for visible leaks; check the tension of the serpentine drive belt for the water pump; if no other problems are found, remove the load on the generator and restart the engine, checking the coolant temperature and shutting the engine down immediately if it starts to overheat, and consult the engine operation and maintenance manual
Overcrank shutdownFuel level low; fuel pump not operating properly; air filter blocked; engine will not startCheck the fuel level in the tank; check for proper operation of the fuel pump; check air filter for blockage; if the engine will not start, consult the engine operation and maintenance manual for additional information on troubleshooting starting problems
Overspeed or underspeed shutdownFrequency above or below 60.0 Hz with no loads on the generator (engine speed requires adjustment)Disconnect all loads and restart the generator, read the frequency (Hz) on the LCD display (should read 60.0 Hz with no loads); if the frequency is above or below 60.0 Hz, adjust the engine speed — see the engine manual for throttle adjustments on mechanical governed units and the electronic governor manual for electronically controlled units
Low fuel level shutdownFuel level low; leaks in the fuel tank; fuel level sender and connecting wiring damagedCheck the fuel level on the Home screen and confirm the generator is sitting level; check for leaks in the fuel tank; check the fuel level sender and the connecting wiring for damage and check for continuity between the sender and the engine controller
Low coolant level shutdownCoolant level low; leaks in coolant hoses, engine block or water pump; coolant mixed with engine oilAllow the engine to cool; check the coolant level in the radiator and add coolant until it is 3/4 in. (1.9 cm) below the filler neck; inspect coolant hoses, engine block and water pump for visible leaks; check engine oil to verify no coolant has mixed with it and consult the engine operator's manual
High coolant temperature shutdownCoolant level low in overflow jug or radiator; radiator shroud and ducting blocked; leaks in coolant hoses, engine block or water pump; serpentine drive belt tension incorrect; generator overloadedCheck the coolant level in the overflow jug; restart the engine and read the coolant temperature, stopping the engine immediately if the coolant temperature is 230°F (110°C) or more; allow the engine to cool, add coolant to the overflow jug if low and check the radiator level, adding coolant until it is 3/4 in. (1.9 cm) below the filler neck; check the radiator shroud and ducting for blockage and remove any foreign matter; inspect coolant hoses, engine block and water pump for visible leaks; check the tension of the serpentine drive belt for the water pump; remove the load on the generator and restart the engine, checking the coolant temperature and shutting the engine down immediately if it starts to overheat
Overspeed or underspeed shutdownEngine speed above or below 60.0 HzDisconnect all loads and restart the generator and read the frequency (Hz) on the LCD display; if the frequency is above or below 60.0 Hz, adjust the engine speed per the engine operator's manual for throttle adjustments on mechanically governed units and the electronic governor manual for electronically controlled units

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

6
Part #DescriptionQtySystem
100-025Air Filter1Air filter Amazon eBay
100-030Oil Filter1Oil filter Amazon eBay
100-045Fuel Filter1Fuel filter Amazon eBay FridayParts $20.19
100-060Coolant Filter1Coolant filter Amazon eBay
100-085Belt2Belt Amazon eBay
100-100Spark Plug1Spark plug Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime23.56.2
Prime50%11.73.1
Prime75%17.84.7
Prime100%23.56.2
Standby18.14.78
Standby100%18.14.78

Available documents