Service parts for the 10000i PMS
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredFuel system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Frequency | 50.0 Hz |
|---|---|
| Standby power | 8 kW |
| Standby kVA | 10 |
| Controller | Panda iControl digital display |
| Oil capacity | 2.8 L |
| Alternator | Fischer Panda Permanent-Magnet-Generator |
| Voltage options | 230 V, 400 V, 120 V, 240 V |
| Phase | 1 |
| Max ambient | 45 °C |
| Dimensions (L×W×H) | 540×445×555 mm |
| Dry weight | 115 kg |
| Sound level | 54.0 dBA @ [7, 3, 1] m |
Filters for the Kubota Z602
1Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel filter | P550012 | Fuel Filter, In-Line | KUBOTA 1258143010, KUBOTA 1258143011, BALDWIN BF840-K1, RENAULT VI 0005490862 | KuduParts $13.00 FridayParts $15.50 |
Maintenance & consumables
for the Kubota Z602| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | RG15842930 | Amazon eBay $15.50 PartsGeek $23.97 FridayParts $16.50 | |||
| Fuel filter | 1258143013 | 300 hr | Amazon eBay $17.87 PartsGeek $6.98 KuduParts $10.00 | ||
| Oil filter | — | ||||
| Battery | — | ||||
| Belt | — | 250 hr | |||
| Coolant | — | ||||
| Oil | 2.8 | — | 150 hr | ||
| Spark plug | — |
Service intervals
6| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| V-belt | Inspect | 50 hr | ||
| V-belt | Replace | 250 hr | Replacement interval must never be exceeded | |
| Fuel filter | Replace | 300 hr | At the latest, depending on fuel contamination | |
| Air filter main element | Replace | 24 mo | At the latest | |
| PMGi heat sinks and fan | Clean | 6 mo | Visual inspect and clean with compressed air | |
| Starter battery | Test | 2 mo | Charge regularly, at least every 2 months |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
11| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | V-belt tension | approx. 1 | cm | pushed in with thumb |
| Other | Compression ratio | 23:1 | ||
| Other | Compression ratio | 24:1 | ||
| Other | Cooling water requirement for seawater circuit | 16-28 | l/min | marine generators only |
| Pressure | Air filter cleaning compressed air pressure | max. 5 | bar | |
| Pressure | Max. exhaust back pressure | 9.3 | kPa | 93 Millibar |
| Speed | Idle running speed | 2400 | rpm | |
| Speed | Rated speed | 2800 | rpm | |
| Temperature | Cooling water temperature difference in-flow to return | approx. 8 | °C | at nominal rating |
| Torque | Cylinder head nut torque | 42 | Nm | |
| Valve clearance | Valve clearance (engine cold) | 0.2 | mm | engine cold |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | GLYSANTIN PROTECT PLUS / G48 | above -40°C | Mixture ratios: 70:30 -20 °C; 65:35 -25 °C; 60:40 -30 °C; 55:45 -35 °C; 50:50 -40 °C | ||
| Engine oil | SAE 10W-40; SAE 5W-40 | API CF | below 0°C | 2.8 l | For ambient temperatures below 0 °C |
| Engine oil | SAE 10W-40 | API CF | 0°C to 25°C | 2.8 l | For ambient temperatures 0 °C to 25 °C |
| Engine oil | SAE 10W-40; SAE 15W-40; SAE 20W-50 | API CF | above 25°C | 2.8 l | For ambient temperatures over 25 °C |
| Fuel | Diesel fuel oil | DIN 590:1999 or better; DIN 590:2009 or better for common rail or particle filter | Do not use alternative fuel; kerosene adversely affects the engine | ||
| Grease | Antiseize | Lubricate sight glass O-ring on optional fuel filter with heat-resistant grease (Antiseize) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
28| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 5 | Starting failed | STARTING FAILS | Shutdown | Acknowledge with Start/Stop button; check starting system and fuel supply. |
| 9 | Watchdog Error | WATCHDOG | Shutdown | Acknowledge with Start/Stop button; check controller. |
| 12 | Winding temperature fault | FAULT: WINDING | Shutdown | Acknowledge with Start/Stop button; check winding temperature and cooling. |
| 13 | Winding temperature out of range | OUT: WINDING | Shutdown | Check winding temperature sensor and wiring. |
| 14 | Exhaust temperature fault | FAULT: EXHAUST | Shutdown | Acknowledge with Start/Stop button; check exhaust temperature and cooling. |
| 15 | Exhaust temperature out of range | OUT: EXHAUST | Shutdown | Check exhaust temperature sensor and wiring. |
| 16 | Engine temperature fault | FAULT: CYL.HEAD | Shutdown | Acknowledge with Start/Stop button; check engine temperature and cooling. |
| 17 | Oil pressure fault | FAULT: OILPRESS | Shutdown | Check oil level and oil pressure; repair if necessary. |
| 18 | Battery voltage low | BATTERY LOW | Shutdown | Recharge battery; check charging system and battery connections. |
| 19 | unexpected stop/Problem with fuel supply | PROBLEM WITH / FUEL SUPPLY! | Shutdown | Check fuel supply, fuel filter and fuel pump. |
| 22 | Emergency stop | EMERGENCY STOP! | Shutdown | Release emergency stop switch; investigate cause. |
| 23 | Engine temperature out of range | OUT: CYL.HEAD | Shutdown | Check cylinder head temperature sensor and wiring. |
| 30 | Inverter overtemp | Inverter overtemp | Shutdown | Check PMGi cooling and air flow. |
| 31 | inverter overload | Inverter overload | Shutdown | Reduce load; check for overload. |
| 32 | inverter communication lost | Inverter com. lost | Shutdown | Check PMGi communication cable and connections. |
| 33 | inverter synchronisation lost | INV. SYNC. FAILED | Shutdown | Check inverter synchronization and connections. |
| 34 | Engine fault (EDC) | ENGINE FAULT | Shutdown | Check engine ECU and engine fault codes. |
| 35 | CAN communication lost | CAN. COMM.LOST | Shutdown | Check CAN bus wiring and connections. |
| 36 | inverter overload slave 1 | L1 OVERLOAD | Shutdown | Reduce load on phase L1. |
| 37 | inverter overload slave 2 | L2 OVERLOAD | Shutdown | Reduce load on phase L2. |
| 38 | inverter overload slave 3 | L3 OVERLOAD | Shutdown | Reduce load on phase L3. |
| 39 | inverter overload slave DC | DC OVERLOAD | Shutdown | Reduce DC load. |
| 40 | Overvoltage | FAULT: OVERVOLTAGE | Shutdown | Check AC output voltage and load. |
| 41 | Undervoltage | FAULT: LOWVOLTAGE | Shutdown | Check AC output voltage and load. |
| 42 | DC-Overvoltage | DC OVERVOLTAGE | Shutdown | Check DC input voltage. |
| 66 | RedundantTempSwitchOff | NOTSTOP! | Shutdown | Check temperature sensors and cooling system. |
| 100 | Communication Error | NO CONNECTION / BUS ERROR! | Shutdown | Check bus wiring and plug connections. |
| 207 | Init failed (no generator type is selected) | INIT FAILED! | Shutdown | Select correct generator type in configuration. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Checking oil-level maintenance
⚠ Burn hazard: generator and coolant can be hot.
Tools: paper towels/cloth, oil dipstick
- Place generator level; for marine generators measure when ship is not lop-sided.
- Run generator about 10 minutes to warm engine, then wait 3 minutes.
- Secure generator against accidental start and open casing.
- Pull oil dipstick, clean it, reinsert and wait 10 seconds.
- Read oil level at lower end of stick; recommended level 2/3 between min and max.
Clean raw water filter maintenance
- Close water cock.
- Release raw water filter regularly from arrears.
- Beat the filter basket; if water seeps through cover check sealing ring and replace if needed.
- Do not seal cover with adhesive or sealant.
First filling and ventilation of the internal cooling water circuit maintenance
⚠ Risk of scalding; hot cooling water can leak from pressure relief valve.
- Fill external expansion tank with coolant to max marking; open its cover.
- Open venting screw at thermostat housing and close when air-free water comes out.
- Start generator unloaded and switch off after approx. 10 seconds.
- Repeat until no more air comes out of venting screw; close venting screws.
- Fill expansion tank to max marking and close.
- Repeat ventilation process 10 operating hours after first start-up if necessary.
Replace the air filter main element maintenance
Tools: screwdriver, compressed air
- Use screwdriver to lever out tension spring.
- Lift the air filter housing.
- Release three snap fastenings and remove lower housing part.
- Remove main element with light turning movement from inner support pipe.
- Clean by blowing out with dry compressed air max. 5 bar or replace after 2 years at latest.
- Reassemble in reverse order.
Replace the air filter mat maintenance
Tools: 8 mm spanner
- Open air suction housing by loosening six screws on housing cover with 8 mm spanner.
- Change the air filter mat.
- Close the suction air housing.
Replacement of engine oil and engine oil filter maintenance
⚠ Burn hazard.
⚠ Used oil is toxic and must be disposed of properly.
Tools: 17 mm open-ended wrench, oil filter wrench, container, oil-resistant mat, paper towels
- Run engine warm, wait 3 minutes, secure against accidental start and open casing.
- Prepare oil-resistant mat and container under oil drain hose.
- Loosen oil filling cap.
- Open oil drain screw with 17 mm wrench and drain used oil.
- Remove used oil filter with filter wrench.
- Clean filter holder and apply thin oil layer to new filter seal.
- Screw in new filter by hand; refit oil drain screw with new sealing.
- Fill engine oil and check level after every 2 litres.
- Run engine 10 minutes, stop, wait and recheck oil level.
Replacement of the fuel filter maintenance
⚠ Clamped inlet and fuel spill precautions required.
- Clamp inlet before exchanging the filter.
- Remove hoses from used filter.
- Fasten hoses to new filter; observe arrow for fuel flow direction.
- For sight-glass version: unscrew housing and element left-hand.
- Screw new filter element into mount.
- Lubricate sight glass O-ring with Antiseize and screw sight glass back right-hand.
Replacement of the impeller maintenance
⚠ Close raw water stop cock before work.
Tools: multigrip pliers
- Close raw water stop cock.
- Remove cover of raw water pump by loosening housing screws.
- Pull impeller from shaft with multigrip pliers and mark its position.
- Check impeller for damage and replace if necessary.
- Lubricate impeller with glycerin or non-mineral oil based lubricant e.g. silicone spray.
- Attach impeller to pump shaft; fasten cover with new seal.
Replacing the V-belt maintenance
⚠ Shut down generator before checking V-belt tension.
Tools: 12 mm wrench, 14 mm wrench
- Loosen fixing screw above alternator with 12 mm wrench.
- Loosen fixing screw below alternator with 14 mm wrench.
- Push alternator toward thermostat housing.
- Replace the V-belt.
- Tension V-belt by pulling alternator back; belt should yield approx. 1 cm with thumb.
- Re-tighten screws above and below alternator.
Ventilating the fuel system maintenance
⚠ Fuel is flammable; no open flames or smoking.
Tools: cloth/Kleenex tissue
- Start the fuel pump using the iControl2 Prime fuel function or START button.
- Open ventilation screw at fuel solenoid valve while START is pressed.
- Place cloth beneath connection to catch escaping fuel.
- Close ventilation screw when fuel runs out without air bubbles; then release START.
- Switch panel OFF.
- Repeat until fuel is bubble-free.
- If necessary loosen injection line connecting nut and repeat; retighten afterward.
Activating/deactivating the autostart function operation
⚠ Automatic start-up danger; ensure generator capsule is closed and warning signs are affixed.
- Select Autostart in set-up menu and confirm with Start/Stop button.
- Select Enable or Disable with cursor buttons.
- Confirm selection with Start/Stop button.
- Setting is saved to EEPROM and controller shuts down.
- After restart, AUTOSTART or STANDBY status indicates state.
Opening the GFK sound insulation capsule operation
- Pull handle in arrow direction and lift lash of closure pin.
- After lifting off lashes, remove sound isolation cover upper part.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 12 V | Starter battery positive cable to solenoid switch of starter motor; negative cable to engine foot | Positive (+), Negative (-) | Install fuse and battery circuit breaker in positive cable within 300 mm of battery. | |
| 24 V | Two 12 V batteries in series | 24 V starter system requires 2x12 V batteries in a row. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Fischer Panda 10000i PMS?
The Fischer Panda 10000i PMS is rated 8 kW standby (10.0 kVA).
What engine is in the Fischer Panda 10000i PMS?
The Fischer Panda 10000i PMS is powered by the Kubota Z602 engine.
What is the oil capacity of the Fischer Panda 10000i PMS?
The Kubota Z602 engine in the Fischer Panda 10000i PMS has an oil capacity of 2.8 liters.
How loud is the Fischer Panda 10000i PMS?
The Fischer Panda 10000i PMS is rated at 54.0 dBA at [7, 3, 1] m, per the manufacturer specification sheet.
How much does the Fischer Panda 10000i PMS weigh?
The Fischer Panda 10000i PMS has a dry weight of 115 kg (253 lb).
What voltage does the Fischer Panda 10000i PMS produce?
The Fischer Panda 10000i PMS is offered in 230 V, 400 V, 120 V, 240 V, 1-phase.
Which alternator is fitted to the Fischer Panda 10000i PMS?
The Fischer Panda 10000i PMS uses a Fischer Panda Permanent-Magnet-Generator alternator.
What fuel filter does the Fischer Panda 10000i PMS use?
The Fischer Panda 10000i PMS uses fuel filter part number 1258143013.
What air filter does the Fischer Panda 10000i PMS use?
The Fischer Panda 10000i PMS uses air filter part number RG15842930.
Repair guides
7- Activating/deactivating the autostart function
- Clean raw water filter
- Priming the fuel system (Prime Fuel)
- Replace the air filter main element
- Replace the air filter mat
- Replacement of the fuel filter
- Replacing the V-belt
Step-by-step procedures compiled from the Fischer Panda service manual for this model.
Parts
12model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 02-145-000-00 | Air filter mat | 1 | Air filter | Amazon eBay |
| 02-146-000-00 | Air filter mat with pull out holder | 1 | Air filter | Amazon eBay |
| 02-147-000-00 | Air filter at housing with snap fasteners | 1 | Air filter | Amazon eBay |
| 02-150-000-00 | Fuel filter | 1 | Fuel filter | Amazon eBay |
| 02-151-000-00 | Coolant filter | 1 | Coolant filter | Amazon eBay |
| 02-160-000-00 | V-belt | 1 | Belt | Amazon eBay |
| F100-02500 | Air Filter | 1 | Air filter | Amazon eBay |
| F100-02600 | Fuel Filter | 1 | Fuel filter | Amazon eBay |
| F100-02700 | Belt | 1 | Belt | Amazon eBay |
| F100-03400 | Oil Filter | 1 | Oil filter | Amazon eBay |
| F100-03500 | Coolant Filter | 1 | Coolant filter | Amazon eBay |
| F100-03600 | Spark Plug | 1 | Spark plug | Amazon eBay |