Home›DuroMax›DuroMax XP12000E

DuroMax XP12000E Generator Set

The DuroMax XP12000E is a 9.5 kW Dual Fuel (Gasoline/Propane) prime generator set. It is available at 120/240 V, single-phase, 60 Hz and rated 79.17 A. It holds about 1.2 L (0.3 gal) of oil. The set measures 762×762×660 mm (30.0×30.0×26.0 in), weighs about 98.4 kg (217 lb) and produces 74 dBA. An integrated tank holds 31 L (8.2 gal), roughly 8 hours of runtime.

1.2 L
Oil capacity
3
Document types

Specifications

FuelDual Fuel (Gasoline/Propane)
Frequency60.0 Hz
Prime power9.5 kW
Oil capacity1.2 L
Voltage options120/240 V
PhaseSingle
Rated current79.17 A
Battery voltage12 V
Battery quantity1
Dimensions (L×W×H)762×762×660 mm
Dry weight98 kg
Wet weight224 kg
Sound level74.0 dBA
Fuel tank31.0 L
Tank runtime8 hr. (gasoline) / 7 hr. (propane) hr

Maintenance & consumables

ItemSpecCapacityPart #Interval
Air filter—100 hr
Fuel filter—50 hr
OilSAE 10W-3040.5 L—8 hr
Spark plugNGK BPR6ES or F6RTC—50 hr

Service intervals

12
ItemActionHoursMonthsNotes
Air CleanerCheck50 hr3 moFirst service — Heavy use
Spark ArrestorCheck50 hr3 mo
spark plugClean100 hr6 moEvery 3 months or 50 hours - clean/adjust
Engine OilChange300 hr12 moFirst service — Normal use
Sediment CupClean100 hr6 mo
Spark ArrestorClean100 hr6 mo
air cleanerChange300 hr12 moEvery 6 months or 100 hours
Fuel Tank / FilterClean300 hr12 mo
Idle SpeedCheck300 hr12 moCheck/Adjust
Valve ClearanceCheck300 hr12 moCheck/Adjust
Combustion ChamberClean500 hr36 mo
Fuel TubeCheck500 hr36 moCheck/Replace

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

1
TypeItemValueUnitCondition
GapSpark plug gap0.7-0.8mm (0.028-0.031 in)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oilSAE 10W-3040.5 fl. oz (1.2 L)Synthetic 5W-30 usable after 8hr break-in; aids cold starting <5C (41F)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

7
Changing the Oil maintenance

⚠ Worn out or dirty oil does not cool the generator properly

Tools: 12mm hex wrench

  1. Unscrew oil drain plug with 12mm hex wrench
  2. Allow oil to drain into approved container
  3. Replace drain plug and tighten with 12mm hex wrench
Checking the Oil maintenance
  1. Make sure the generator is on a level surface.
  2. Unscrew the oil filler/dipstick cap.
  3. Wipe the oil off the stick with a dry cloth.
  4. Insert dipstick and remove it again.
  5. If no oil on stick or only at very end, add oil until crankcase is full.
  6. Replace the cap when finished.
Cleaning the Air Filter maintenance
  1. Release clips on top and bottom of filter cover, remove cover
  2. Remove sponge-like elements from casing
  3. Wipe dirt from inside empty air cleaner casing
  4. Wash elements in household dish detergent and warm water
  5. Pat dry with cloth
  6. Soak dry elements in small amount of engine oil, ring out excess
  7. Replace elements in casing and replace cover
Cleaning the Fuel Filter Cup maintenance

Tools: wrench

  1. Turn fuel valve to OFF
  2. Unscrew fuel filter cup from fuel valve using wrench
  3. Clean cup of all sediment using rag or brush
  4. Reinstall fuel filter cup
Emptying the Gas Tank maintenance

⚠ Do not store fuel from one season to another

Tools: wrench

  1. Turn fuel valve to OFF
  2. Remove fuel filter cup
  3. Empty fuel filter cup of any fuel
  4. Turn fuel valve to ON, drain gas from generator into funnel/container
  5. Turn fuel valve to OFF
  6. Reinstall fuel filter cup
  7. Store emptied gasoline with fuel stabilizer
Spark Plug Maintenance maintenance

Tools: spark plug wrench, gap gauge, wire brush

  1. Pull spark plug cap off
  2. Unscrew spark plug with spark plug wrench
  3. Visually inspect; discard if cracked/chipped, recommend F6RTC/NGK BPR6ES
  4. Measure plug gap with gauge, should be 0.7-0.8mm (0.028-0.031 in)
  5. Clean and re-gap if reusing
  6. Screw spark plug back in
  7. Replace spark plug cap
Changing / Inspecting the Carbon Brushes repair

⚠ Inspect every 250 running hours

  1. Remove 2 bolts of generator cover, pull cover off
  2. Remove bolt holding carbon brush
  3. Remove 2 wires from AVR on carbon brush
  4. Install new carbon brush with bolt
  5. Insert and connect 2 wires from AVR, connect + and - correctly
  6. Replace back cover with 2 bolts

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
120/240Vsingle120/240V 4-prong receptacleCan provide 120V or 240V
120Vsingle120V only receptacleFor 120V devices only

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What kind of fuel does the DuroMax XP12000E run on?

The DuroMax XP12000E runs on Dual Fuel (Gasoline/Propane).

How much oil does the DuroMax XP12000E take?

The DuroMax XP12000E has an engine oil capacity of 1.2 liters (1.3 US quarts), per the manufacturer specification sheet.

What is the sound level of the DuroMax XP12000E?

The DuroMax XP12000E is rated at 74.0 dBA, per the manufacturer specification sheet.

What is the dry weight of the DuroMax XP12000E?

The DuroMax XP12000E has a dry weight of 98 kg (216 lb).

How big is the fuel tank on the DuroMax XP12000E?

The DuroMax XP12000E has a 31 liter (8 US gallon) fuel tank, giving about 8 hr. (gasoline) / 7 hr. (propane) hours of runtime.

What voltage does the DuroMax XP12000E produce?

The DuroMax XP12000E is offered in 120/240 V, Single-phase.

What battery does the DuroMax XP12000E use?

The DuroMax XP12000E uses 1 battery, 12 V each, per the manufacturer specification sheet.

Troubleshooting

15

Symptoms & remedies

SymptomCauseRemedy
The engine will not startEngine switch is "Off"Set engine switch to "On"
The engine will not startFuel valve is "Closed"Turn the fuel valve to "Open"
The engine will not startChoke is openClose the choke
The engine will not startThe engine is out of fuelAdd fuel
The engine will not startFuel is old or contaminatedChange fuel
The engine will not startSpark plug is dirtyClean spark plug
The engine will not startSpark plug is brokenReplace spark plug
The engine will not startThe generator is not levelMove the generator to a level surface
The engine will not startOil is lowAdd/change the oil
Engine runs, but there is no electrical outputThe circuit breaker is "Off"Turn "On" circuit breaker
Engine runs, but there is no electrical outputWiring connection is badReplace extension cord(s)
Engine runs, but there is no electrical outputDevice connected to generator is malfunctioningDisconnect malfunctioning device
The generator runs but does not support all electrical devices connectedGenerator is overloadedDisconnect 1 or more items to reduce the load
The generator runs but does not support all electrical devices connectedDevice connected to the generator is badDisconnect malfunctioning device
The generator runs but does not support all electrical devices connectedThe air filter is dirtyClean/ replace the air filter

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Available documents

Spec sheet (DuroMax)Reference (DuroMax)Owner's manual (DuroMax)

This page was generated from the 3 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.