DuroMax XP12000E — Changing / Inspecting the Carbon Brushes
Repair & overhaul · AVR/carbon brushes
For the DuroMax XP12000E, from the DuroMax owner's manual.
Applies to: DuroMax XP12000E
Before you start
- Inspect every 250 running hours
Procedure
- Remove 2 bolts of generator cover, pull cover off
- Remove bolt holding carbon brush
- Remove 2 wires from AVR on carbon brush
- Install new carbon brush with bolt
- Insert and connect 2 wires from AVR, connect + and - correctly
- Replace back cover with 2 bolts
Source: DuroMax owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.