Service parts for the DGAE
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredFuel system
1 requiredOil system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | 2-D Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 40 kW |
| Standby kVA | 50 |
| Controller | Detector 7 (standard); Detector 12 (optional) |
| Oil capacity | 11.4 L |
| Alternator | YD (4-pole) |
| Voltage options | 12 V |
| Phase | 1 and 3 |
| Power factor | 0.8 |
| Battery group | 31 |
| Battery cranking | 625 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Starting system | 12 V DC |
| Coolant capacity | 17.5 L |
Engine
| Oil capacity | 11.4 L |
|---|---|
| Coolant capacity | 17.5 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the Cummins/Onan 6AT3.4| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Standard Air Cleaner | FS1343 | Amazon eBay | ||
| Fuel filter | Fuel Filter | FS1245 | Amazon eBay | ||
| Oil filter | 51592 | 200 hr | Amazon eBay FridayParts $15.89 | ||
| Battery | — | 200 hr | |||
| Belt | — | ||||
| Coolant | — | ||||
| Oil | — | 50 hr | |||
| Spark plug | — |
Service intervals
7| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Crankcase oil | Change | 50 hr | First service — After first 50 hours of operation on new generator sets. | |
| Valve lash clearance | Check | 50 hr | First service — See Note 3; perform after first 50 hours of operation on new sets. | |
| Battery electrolyte level | Check | 200 hr | Check at least every 200 hours of operation. | |
| Crankcase breather cap (turbo) | Clean | 400 hr | DGAE turbocharged engines; clean with solvent and allow to dry. | |
| Generator bearing | Inspect | 1000 hr | Inspect for evidence of outer case rotation every 1000 hours. | |
| Cooling system | Drain | 12 mo | Drain, flush, and refill once a year. | |
| Generator bearing | Replace | 10000 hr | 60 mo | Standby: every five years. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
60| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Trailer brake actuator stroke length | 1 | inch (25 mm) | maximum before brake shoe readjustment |
| Gap | Float switch test feeler gauge | 0.125 | inch (3 mm) | between float and C-clip stop |
| Gap | Magnetic pickup adjustment | 1/2 turn out from tooth | turn | after contact with flywheel tooth |
| Gap | Overspeed switch air gap | 0.005 | inch (0.13 mm) | minimum |
| Gap | Overspeed switch air gap | not less than 0.005 | inch (0.13 mm) | |
| Other | Battery charge threshold | 1.215 | charge if reading is below | |
| Other | Battery electrolyte specific gravity | 1.260 | specific gravity | fully charged at 80°F (27°C) |
| Other | Battery electrolyte specific gravity | about 1.260 | specific gravity | fully charged at 80°F (27°C) |
| Other | Battery specific gravity fully charged | 1.260 | corrected to 80°F (27°C) | |
| Other | Brake shoe adjustment | 10 | clicks | back off from point wheel cannot be turned by hand |
| Other | Control heater element power | 75 | watts at 120 VAC | |
| Other | Cooling system fill rate | 3 | gallons/minute | |
| Other | Cycle cranking | 15 seconds crank, 15 seconds rest, 3 cycles | seconds | 12-lamp control |
| Other | Fan belt tension | 60 | lbs (267 N) | |
| Other | Heavy duty air cleaner air drying time | 24 | hours | minimum |
| Other | Overcrank cranking limit | 75 | seconds | |
| Pressure | Engine oil pressure (normal) | 30 to 55 | psi (207 to 380 kPa) | engine at operating temperature |
| Pressure | Low oil pressure shutdown | 14 | psi (97 kPa) | |
| Pressure | Low oil pressure shutdown | below 14 | psi (97 kPa) | fault time delayed about 10 seconds following starter disconnect and inhibited during cranking |
| Pressure | Pre-low oil pressure alarm | 20 | psi (137 kPa) | or less |
| Resistance | Actuator coil resistance | 1 ±10% | ohm | at 77°F (25°C); leads disconnected |
| Resistance | Control heater element resistance | 192 | ohms | dissipates 75 watts at 120 VAC |
| Resistance | Exciter rotor winding resistance | 0.54 | ohms | at 77°F (25°C), ±10% |
| Resistance | Exciter rotor winding resistance | 0.54 ±10% | ohms | at 77°F (25°C) |
| Resistance | Exciter rotor winding resistance | 0.645 | ohms | at 77°F (25°C), ±10% |
| Resistance | Exciter rotor winding resistance | 0.645 ±10% | ohms | at 77°F (25°C) |
| Resistance | Exciter stator insulation resistance to lamination | 100,000 | ohms | minimum; 500 VDC or more |
| Resistance | Exciter stator winding resistance | 12.4 ±10% | ohms | at 77°F (25°C) |
| Resistance | Exciter stator winding resistance | 14.5 ±10% | ohms | at 77°F (25°C) |
| Resistance | Exciter stator winding resistance, 4A2.3/6A3.4/6AT3.4 | 14.5 | ohms | at 77°F (25°C), ±10% |
| Resistance | Exciter stator winding resistance, DGAB/DGAC/DGAD/DGAE | 12.4 | ohms | at 77°F (25°C), ±10% |
| Resistance | Exciter stator winding resistance, DL4 | 20.0 | ohms | at 77°F (25°C) |
| Resistance | Exciter stator winding resistance, DL6 | 25.0 | ohms | at 77°F (25°C) |
| Resistance | Exciter stator winding resistance, DL6T | 40.0 | ohms | at 77°F (25°C) |
| Resistance | Governor actuator coil resistance | 1 ±10% | ohms | at 77°F (25°C); resistance to case infinity |
| Resistance | Insulation resistance to ground | 100,000 or greater | ohms | 500 VDC or more megger; exciter stator/rotor and main rotor/stator |
| Resistance | Magnetic pickup DC resistance | 175 ±15% | ohms | at 77°F (25°C); disconnected from terminals 5 and 6 |
| Resistance | Magnetic pickup coil resistance | 175 ±15% | ohms | at 77°F (25°C); leads to case infinity |
| Resistance | Main rotor insulation resistance to shaft | 100,000 | ohms | minimum; 500 VDC or more |
| Resistance | Main rotor resistance at stack length 10.50 in (267 mm) | 2.55 | ohms | at 77°F (25°C) ±10% |
| Resistance | Main rotor resistance at stack length 5.88 in (149 mm) | 2.75 | ohms | at 77°F (25°C) ±10% |
| Resistance | Main rotor resistance at stack length 7.12 in (181 mm) | 1.80 | ohms | at 77°F (25°C) ±10% |
| Resistance | Main rotor resistance at stack length 8.75 in (222 mm) | 2.04 | ohms | at 77°F (25°C) ±10% |
| Resistance | Main rotor winding resistance, stack length 10.50 in (267 mm) | 2.55 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main rotor winding resistance, stack length 10.50 in (267 mm), QSA-series | 2.91 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main rotor winding resistance, stack length 5.88 in (149 mm) | 2.75 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main rotor winding resistance, stack length 7.12 in (181 mm) | 1.80 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main rotor winding resistance, stack length 7.12 in (181 mm), QSA-series | 1.98 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main rotor winding resistance, stack length 8.75 in (222 mm) | 2.04 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main rotor winding resistance, stack length 8.75 in (222 mm), QSA-series | 2.24 | ohms | at 77°F (25°C), ±10% |
| Resistance | Main stator insulation resistance | 100,000 | ohms | minimum; 500 VDC or more |
| Resistance | QSA main rotor resistance at stack length 10.50 in (267 mm) | 2.91 | ohms | at 77°F (25°C) ±10% |
| Resistance | QSA main rotor resistance at stack length 5.12 in (130 mm) | 2.55 | ohms | at 77°F (25°C) ±10% |
| Resistance | QSA main rotor resistance at stack length 5.88 in (149 mm) | 2.75 | ohms | at 77°F (25°C) ±10% |
| Resistance | QSA main rotor resistance at stack length 7.12 in (181 mm) | 1.98 | ohms | at 77°F (25°C) ±10% |
| Resistance | QSA main rotor resistance at stack length 8.75 in (222 mm) | 2.24 | ohms | at 77°F (25°C) ±10% |
| Resistance | Transformer TX1 coil resistance | 370; 313 | ohms | at 77°F (25°C), within ±10%; no continuity between windings or to ground |
| Resistance | Transformer TX1 winding resistance | 313 | ohms | within ±10% at 77°F (25°C) |
| Resistance | Transformer TX1 winding resistance | 370 | ohms | within ±10% at 77°F (25°C) |
| Speed | Engine speed equivalent of frequency | 30 | r/min per Hz |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | Ethylene glycol antifreeze (permanent type) and clean water; 50/50 mixture | Use soft water; contains rust and corrosion inhibitor; no stop-leak additive. Capacities: DGAB 11.5 L (12.2 QT); DGAC/DGAD 16.8 L (17.8 QT); DGAE 17.5 L (18.5 QT). | |||
| Engine oil | API CD/SF or CE/SF; multigrade | API CD/SF or CE/SF | Preferred oil grades per Table 5-2; choose grade for lowest expected temperature. Capacities: DGAB 5.7 L (6 QT); DGAC/DGAD 8.5 L (9 QT); DGAE 11.4 L (12 QT). | ||
| Fuel | ASTM 2-D (No. 2 Diesel) or ASTM 1-D (No. 1 Diesel) | Minimum Cetane number 45 | Use No. 1 diesel when ambient temperatures are below 0°C (32°F) and during long periods of light load. Low sulfur; cloud point at least 10 degrees below lowest expected fuel temperature. | ||
| Other | DOT 3 | Trailer brake system; reservoir should be at least half full | |||
| Other | DOT-3 heavy duty hydraulic fluid | Trailer brake system bleeding | |||
| Other | distilled water | Battery electrolyte; add distilled water to maintain proper level. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
14| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| FAULT 1 | Fault 1 | Undedicated fault; may be programmed as shutdown or non-shutdown and as timed or non-timed; normally set for timed shutdown. | Investigate optional fault selection; contact dealer if needed. | |
| FAULT 2 | Fault 2 | Undedicated fault; same features as Fault 1; normally set for non-timed shutdown. | Investigate optional fault selection; contact dealer if needed. | |
| HI ENG TEMP | High engine temperature shutdown | Engine shut down because coolant temperature rose above 222°F (106°C) or coolant level is low. | Shutdown | Allow to cool; check coolant level, airflow, and fan belt; reset and restart; contact dealer if fault persists. |
| LO FUEL | Low fuel | Fuel supply marginally low. | Warning | Check fuel supply and replenish. |
| LO PRES | Low oil pressure shutdown | Engine shut down because oil pressure dropped below 14 psi (97 kPa). | Shutdown | Check oil level, lines, and filters; reset and restart; contact dealer if pressure is not 30 to 55 psi. |
| LOW ENG TEMP | Low engine temperature | Engine temperature marginally low for starting; indicates inoperative coolant heater. Lamp lights when engine coolant temperature is 70°F (21°C) or lower. | Warning | Check coolant heater power, fuse, cord, and coolant level; contact dealer if fault persists. |
| LOW OIL PRES | Low oil pressure shutdown | Red lamp indicates engine shutdown because of critically low oil pressure. | Shutdown | Check oil level and LOP switch; inspect engine. |
| OVERCRANK | Overcrank shutdown | Starter locked out because of excessive cranking time. | Shutdown | Check fuel system, fuel filter, and air filter; reset and restart; contact dealer if fault persists. |
| OVERSPEED | Overspeed shutdown | Engine shut down because of excessive speed. | Shutdown | Contact authorized dealer or distributor for service. |
| PRE HI ENG TEMP | Pre-high engine temperature | Engine temperature marginally high, 202°F (94°C). | Warning | Reduce load if possible, check airflow, and improve ventilation; if engine can be stopped follow high engine temperature procedure. |
| PRE HIGH ENG TEMP | Pre-high engine temperature | Yellow lamp indicates engine temperature is marginally high. | Warning | Find and correct cause. |
| PRE LO OIL PRES | Pre-low oil pressure | Oil pressure marginally low, 20 psi (137 kPa) or less. | Warning | Find and correct cause as soon as possible. |
| RUN | Run | All engine systems normal. | Info | No corrective action required. |
| SWITCH OFF | Switch off | Generator set is not in automatic start operation mode. | Warning | Move Run/Stop/Remote switch to REMOTE for automatic starting. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Adjust magnetic pickup adjustment
Tools: Compressed air, Jam nut wrench
- Rotate engine so ring gear tooth is centered in MPU hole.
- Clean mounting hole with compressed air.
- Turn MPU in until it contacts flywheel tooth directly below.
- Turn out 1/2 turn and lock with jam nut.
- Be sure pickup does not rotate when tightening jam nut.
Adjust voltage adjust potentiometer R21 adjustment
⚠ Contact with high voltage can cause severe personal injury or death.
Tools: Insulated screwdriver
- Loosen locking nut of R21 and adjust to mid-range.
- Start genset and bring temperature to normal.
- With no load, turn Phase Selector to read output voltage and current.
- Adjust R32 for approximate desired voltage.
- Fine-adjust with R21 and tighten locking nut without changing setting.
Adjust voltage regulator adjustment
⚠ Use insulating mat or dry wood platform when control doors are open.
Tools: Insulated screwdriver, Accurate voltmeter
- Open control panel doors and set S1, S2, and S3 per table.
- Connect accurate voltmeter to TB1-2 and TB1-3 if no AC meter.
- Start genset and bring temperature to normal.
- Turn R32 to set no-load voltage.
- Stop genset and close control panel doors.
Calibrate electronic governor adjustment
⚠ Keep hands and fingers clear while performing tests on operating equipment.
Tools: Tachometer or frequency meter
- Check actuator linkage does not bind through full travel.
- Attach tachometer or frequency meter.
- Set GAIN adjustment to second mark from zero.
- Disconnect governor rod from throttle lever.
- Start genset and adjust right stop to 72 Hz for 60 Hz gensets.
- Adjust left stop to take up slack and tighten locknut.
- Stop, attach governor rod, start, and adjust SPEED to 60 or 50 Hz.
- Connect load and adjust GAIN clockwise until stable.
Electronic governor adjustment/calibration adjustment
⚠ Contact with rotating machinery can cause severe personal injury or death.
Tools: Tachometer or frequency meter, Screwdriver
- Check actuator linkage does not bind through full travel; ensure terminals 7 and 8 are jumpered.
- Attach tachometer to engine or frequency meter to generator if control panel lacks one.
- Set Controller GAIN adjustment to second mark from zero.
- Disconnect governor rod from throttle lever.
- Place Run/Stop/Remote switch in Run position to start genset.
- Adjust right stop screw on mechanical governor to obtain 72 Hz (2160 r/min) for 60 Hz gensets or 62 Hz (1860 r/min) for 50 Hz gensets.
- Adjust left stop screw to just take up slack, then tighten locknut without binding shaft.
- Stop genset, attach governor rod to throttle lever, start, and adjust Controller SPEED screw for 60 Hz or 50 Hz.
- Connect full rated load; if genset cannot manage load, shorten governor rod one-half turn and repeat; tighten locknuts.
- Connect 1/4 rated load; turn GAIN screw clockwise until actuator hunts, then back off until stable.
- Stop genset, wait 30 seconds for turbo coast down if equipped, restart, and check for speed overshoot.
- Restart genset and check frequency and stability under various loads.
- Stop genset and remove tachometer or frequency meter if attached.
Fan Belt Adjustment adjustment
- Loosen alternator bolt passing through elongated slot in mounting bracket.
- Slide alternator until fan belt tension is 60 lbs (267 N).
- Tighten alternator mounting bolt to lock alternator in place.
- Check tension and repeat if necessary.
Voltage adjust potentiometer R21 adjustment
⚠ Contact with high voltage can cause severe personal injury or death.
Tools: Screwdriver
- Loosen locking nut of R21 on control front panel and adjust R21 to mid-range.
- Start genset and operate to bring temperature to normal.
- With no load, turn Phase Selector switch to read output voltage/current.
- Adjust R32 on voltage regulator for approximate desired voltage.
- Fine-adjust voltage with R21; tighten locking nut carefully without changing setting.
- Move Phase Selector switch to Off, stop genset, and set control for standby readiness.
Voltage regulator adjustment adjustment
⚠ Contact with high voltage can cause severe personal injury or death.
Tools: Insulated screwdriver, Accurate voltmeter
- Open control panel doors and set S1, S2, S3 per correct stability range and mode.
- With AC meter option use panel meter; without it connect accurate voltmeter to regulator TB1-2 and TB1-3.
- Start genset and operate to bring temperature to normal.
- Using insulated screwdriver, turn R32 potentiometer to increase or decrease no-load voltage to proper setting.
- Stop genset, close control doors, and set control for operation readiness.
Control switch check diagnostic
Tools: Ohmmeter
- Remove battery B+ cable.
- Place ohmmeter across switch contacts.
- Open and close switch while observing ohmmeter; normally open should show infinite open and continuity closed; normally closed opposite.
Fuel solenoid check diagnostic
Tools: Jumper wire
- Remove harness B+ lead connection from fuel solenoid and jumper separate B+ connection to terminal.
- Injection pump should click.
- If no click is heard, replace fuel solenoid.
Relay check diagnostic
Tools: Voltmeter, 12 VDC source
- Connect 12 VDC across relay coil terminals; relay should activate if coil is okay.
- Connect 12 VDC to one side of relay contacts.
- Connect voltmeter between other side of contacts and 12-volt source; 12 volts when relay energized indicates contact is okay.
Solenoid check diagnostic
Tools: Voltmeter, Jumper wires
- Apply battery positive (B+) to terminal marked S.
- Jumper a ground wire to solenoid ground bracket; solenoid should activate.
- If contacts are good, 12 VDC should be read between terminal 1 and ground; voltage drop across contact should not exceed one volt.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 208 VAC | Switch S1 position 1 | stator T7 and T8 | Transformer TX1 primary H1-H3 | |
| 240 VAC | Switch S1 positions 2 and 3 | stator T7 and T8 | Transformer TX1 primary H3-H5 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the Cummins/Onan DGAE?
The Cummins/Onan DGAE is rated 40 kW standby (50.0 kVA).
What engine does the Cummins/Onan DGAE use?
The Cummins/Onan DGAE is powered by the Cummins/Onan 6AT3.4 engine.
What fuel does the Cummins/Onan DGAE use?
The Cummins/Onan DGAE runs on 2-D Diesel.
What's the oil capacity on a Cummins/Onan DGAE?
The Cummins/Onan 6AT3.4 engine in the Cummins/Onan DGAE has an oil capacity of 11.4 liters.
What is the coolant capacity of the Cummins/Onan DGAE?
The Cummins/Onan DGAE cooling system holds 17.5 liters (4.6 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What voltage does the Cummins/Onan DGAE produce?
The Cummins/Onan DGAE is offered in 12 V, 1 and 3-phase.
How many cold cranking amps does the Cummins/Onan DGAE require?
The Cummins/Onan DGAE uses 1 battery, 12 V each, 625 CCA, group 31, per the manufacturer specification sheet. The starting system is 12 V DC.
Which alternator is fitted to the Cummins/Onan DGAE?
The Cummins/Onan DGAE uses a YD alternator. It has 4 poles.
Which oil filter part number does the Cummins/Onan DGAE take?
The Cummins/Onan DGAE uses oil filter part number 51592.
What fuel filter does the Cummins/Onan DGAE use?
The Cummins/Onan DGAE uses fuel filter part number FS1245.
Which air filter part number does the Cummins/Onan DGAE take?
The Cummins/Onan DGAE uses air filter part number FS1343.
Troubleshooting
6Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| PRE HI ENGINE TEMP lamp lights. Engine continues to operate. | Indicates engine has begun to overheat and engine temperature has risen to approximately 202°F (94°C). | If generator is powering non-critical and critical loads and cannot be shutdown, use the following: Reduce load if possible by turning off non-critical loads; Check air inlets and outlets and remove any obstructions to airflow; Open doors or windows in generator area to increase ventilation. If engine can be stopped, follow procedure in step 3. |
| Green RUN lamp lights following engine start-up. | Indicates all engine systems are normal. | No corrective action required. |
| HI ENG TEMP lamp lights. Engine shuts down. | Indicates engine has overheated (engine temperature has risen above 222°F/106°C) or coolant level is low (sets with coolant level sensor). | Allow engine to cool down completely before proceeding with the following checks: Check coolant level and replenish if low. Look for possible coolant leakage points and repair if necessary; Check for obstructions to cooling airflow and correct as necessary; Check for a slipping fan belt and tighten if loose; Reset control and restart after locating and correcting problem. Contact an authorized dealer or distributor if none of the above. |
| PRE LO OIL PRES lamp lights. Engine continues to operate. | Indicates engine oil pressure has dropped to 20 psi (138 kPa). | If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow step 5 procedure. If engine can be stopped, follow procedures in step 5. |
| LO OIL PRES lamp lights. Engine shuts down | Indicates engine oil pressure has dropped to 14 psi (97 kPa). | Check oil level, lines and filters. If oil system is okay but oil level is low, replenish. Reset control and restart. Contact an authorized dealer or distributor if oil pressure is not in the range of 30 to 55 psi (206 to 379 kPa). |
| OVERCRANK lamp lights and engine stops cranking. or Engine runs, shuts down, and LO OIL PRES lamp lights. | Indicates possible fuel system problem. | Check for empty fuel tank, fuel leaks, or plugged fuel lines and correct as required; Check for dirty fuel filter and replace if necessary (see MAINTENANCE section); Check for dirty or plugged air filter and replace if necessary (see MAINTENANCE section); Refer to Step 5; Reset the control and restart after correcting the problem. Contact an authorized dealer or distributor for service if none of the above. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan DGAE troubleshooting guide (25 entries) →
Repair guides
30- AC Generator Inspection
- AC voltage regulator replacement
- Adjust magnetic pickup
- Adjust voltage adjust potentiometer R21
- Adjust voltage regulator
- Bleeding trailer brakes
- Calibrate electronic governor
- Control switch check
- Control wiring connections
- Crankcase Breather Cleaning (DGAE)
- Electronic governor adjustment/calibration
- Fan belt replacement (QSA series)
- Filling Cooling System
- Flash the exciter field
- Flashing the exciter field
- Flushing and Cleaning Cooling System
- Fuel pump motor wiring connections
- Priming High Pressure Fuel System
- Priming Low Pressure Fuel System
- Removing voltage reconnection panel assembly
Step-by-step procedures compiled from the Cummins/Onan service manual for this model.
Parts
6| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 193-0244 | Sender, Oil Pressure (E1) | 1 | Sensor | Amazon eBay |
| 309-0169 | Switch, Low Oil Pressure | 1 | Sensor | Amazon eBay |
| FS1245 | Fuel Filter | Fuel filter | Amazon eBay | |
| FS1343 | Standard Air Cleaner | Air filter | Amazon eBay | |
| 718-1067 | Screw. Hex Head | 1 | Service part / kit | Amazon eBay |
| TB21 | TERMINAL BLOCK | 1 | Service part / kit | Amazon Amazon Amazon eBay eBay eBay NAPA $224.81 FridayParts $57.30 |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.