Home Fuel consumption80–85 kW Diesel

80–85 kW Diesel Generator Fuel Consumption

Manufacturer-documented fuel consumption for 27 80–85 kW Diesel generator sets — median 5.18 gal/h at full load, 2.91 gal/h at half load.

Compare 80–85 kW Diesel generator specs side-by-side →

Consumption by model

27
ModelkWgal/h @ 50%gal/h @ 100% Tank (L)Runtime @ 50% (h)
Caterpillar D80803.576.00
Caterpillar DE110E2803.336.3125019.8
Cummins/Onan C80 D6C800.971.81984267.4
Cummins/Onan DGCG800.741.48248.6
Cummins/Onan DGDA802.91125
Cummins/Onan DSFAE803.436.8953040.8
FG Wilson P100E805.47227
FG Wilson P80802.915.5525022.7
Generac SD080803.704.4151036.4
Kohler 80EFOZ803.125.92
Kohler 80EOZ802.725.18
Kohler 80ROZJ802.514.99
MTU 4R0113 DS80801.372.62
MTU 4R0120 DS80801.372.62
MTU MTU 4R0113 DS80801.372.6214527.9
MTU MTU 4R0120 DS80801.372.62
Northern Lights M80A13806.08
Olympian GEP110803.096.7925021.4
SDMO J80U803.045.55
Terex T70C800.901.59606178.2
Terex T90800.901.59
FG Wilson P88-3812.510.77768.0
Hipower HJW 85 M6813.656.05
Caterpillar C4.4821.20
Perkins 1006TG1A823.015.76
Kohler 80REOZJ833.806.2921514.9
Perkins 1104C-44TAG18310.3012.42

Figures from each model’s own manufacturer documentation (spec sheets and manuals); runtime = documented tank capacity ÷ consumption at 50% load. Verify against the datasheet for your exact configuration.

Common questions

How much fuel does a 80–85 kW Diesel generator use?

Across 27 models with manufacturer data, full-load consumption runs 0.77–12.42 gal/h (median 5.18); at 50% load the median is 2.91 gal/h.

How long will a 80–85 kW Diesel generator run on a full tank?

At 50% load, documented tank sizes give 8.0–267.4 hours (median 22.7 h) across 11 models.