HomeGeneracGenerac SD080

Generac SD080 Generator Set

The Generac SD080 is a 80 kW (80 kVA) Diesel standby generator set powered by a Generac 3.9DTA engine. It is available at 120/240 V, 120/208 V, 277/480 V and 346/600 V, ['single', 'three']-phase and 60 Hz. It holds about 13.6 L (3.6 gal) of oil and 17.44 L (4.6 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 2 group-4 batteries rated 995 CCA at 12 V. The set measures 2362.2×1016×1244.6 mm (93.0×40.0×49.0 in), weighs about 1100 kg (2425 lb) and produces 79 dBA at 7 m.

80 kW
Standby
3.9 L
Displacement
13.6 L
Oil capacity
2
Document types

How to read your Generac serial & model number →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power80 kW
Standby kVA80
Prime power64 kW
EmissionsEPA Certified Stationary Emergency
ControllerDigital H Control Panel
Oil capacity13.6 L
Alternator390 (4-pole, Class H insulation)
Voltage options120/240 V, 120/208 V, 277/480 V, 600 V
Phasesingle,three
Power factor[1.0, 0.8]
Battery group4DLT
Battery cranking995 CCA
Battery voltage12 VDC V
Battery quantity2
Coolant capacity17.44 L
Max ambient40 °C
Dimensions (L×W×H)2362×1016×1244 mm
Dry weight1100 kg
Sound level79.0 dBA @ 7 m

Engine

Generac 3.9DTA
Oil capacity18.0 L
Coolant capacity6.4 L
Displacement3.9 L
AspirationTurbocharged/Aftercooled
Rated speed1800 rpm

Maintenance & consumables

for the Generac 3.9DTA
ItemSpecCapacityPart #Interval
Air filter find
Fuel filterSingle Cartridge find
Oil filterFull flow, Cartridge find
Belt find
Coolant15.9 liters
OilGear18.0 liters

Common questions

What is the power rating of the Generac SD080?

The Generac SD080 is rated 80 kW standby (80.0 kVA).

What engine does the Generac SD080 use?

The Generac SD080 is powered by the Generac 3.9DTA engine.

What fuel does the Generac SD080 use?

The Generac SD080 runs on Diesel.

What is the oil capacity of the Generac SD080?

The Generac 3.9DTA engine in the Generac SD080 has an oil capacity of 18.0 liters.

What alternator does the Generac SD080 use?

The Generac SD080 uses a 390 alternator. It has 4 poles. Insulation class H.

Fuel consumption

RatingLoadL/hgal/h
Prime25%5.41.4
Prime50%9.82.6
Prime75%13.83.6
Prime80%13.83.7
Prime100%16.74.4
Standby25%7.92.1
Standby50%14.03.7
Standby75%19.75.2
Standby80%17.34.6
Standby100%23.86.3

Available documents

Brochure — 0166950SBY (Generac)Spec sheet — 0166810SBY (Generac)Spec sheet — 0166930SBY (Generac)Spec sheet — 0169830SBY (Generac)Spec sheet — 0184590SBY (Generac)Spec sheet — 0k5092-sd080-4-5l (Generac)Spec sheet — sd080-80kw-diesel-generator-specsheet (Generac)Spec sheet — sd080 39ta (Generac)

Other sets with this engine