The Cummins/Onan HDKAS is a 0.9 L 3-cylinder liquid-cooled engine rated at 1800 rpm. It powers generator sets from Cummins/Onan, including the HDKA. It holds 4.5 L (1.2 gal) of oil and 4.73 L (1.2 gal) of coolant.
Also known as: Cummins HDKAS
| Oil capacity | 4.5 L |
|---|---|
| Coolant capacity | 4.73 L |
| Displacement | 0.898 L |
| Cylinders | 3 |
| Aspiration | Liquid-cooled |
| Rated speed | 1800 rpm |
How to read your Cummins/Onan engine serial & model number →
| Code | Meaning |
|---|---|
| 1 | Shutdown due to high engine coolant temperature |
| 2 | Shutdown due to a loss of engine oil pressure |
| 3 | Service fault — press Stop once to cause the two-digit, second-level shutdown code to blink |
| 4 | Cranking time exceeded 35 seconds |
| Symptom | Cause | Remedy |
|---|---|---|
| Engine does not crank | Battery dead | Check battery per Checkout [A] and recharge or replace; Check battery charger operation per Checkout [C] |
| Engine does not crank | CB11 circuit breaker open or B+ wiring to starter solenoid faulty | Check CB11 circuit breaker; if okay, jumper battery cable B+ connection to B1 starter solenoid terminal; check B+ wiring between K11 and B1 solenoid terminal and replace if bad; check K1 plunger travel for freedom to bottom in solenoid (necessary to open pull coil circuit) |
| Engine does not crank | No battery voltage between K11 terminal S and ground with S11 in Start position | Check B+ wiring to S11, and between S11 and K11; check NC contacts of A11-K15 and replace if bad |
| Engine does not crank | K11 does not energize | Test per Checkout [D] and replace if bad |
| Engine does not crank | No battery voltage at B1 solenoid terminal with S11 in Start position | Check battery cables for clean tight connections (ref. Checkout [B]); check B1 starter solenoid and motor: if bad, repair or replace |
| Engine cranks but does not start | Engine not getting fuel (exhaust smoke should be blue-white and fuel flow steady from fuel return line) | Check fuel system: fuel tank level, shut-off valves, fuel lines and connections, fuel filters, fuel pump and injection pump |
| Engine cranks but does not start | Incorrect fuel | See Operator's Manual recommendations |
| Engine cranks but does not start | Battery B+ not applied to glow plug heaters when switch S11 is in Preheat and Start positions | Check switch S11 per Checkout [G]; check heater relay per Checkout [E]; check heater wiring |
| Engine cranks but does not start | K14 fuel solenoid does not energize when S11 is in Start position | Check B+ circuit through S11; test S11 per Checkout [G]; test K14 per Checkout [F] |
| Engine starts but stops after running several seconds | Fault condition indicated by fault breaker CB12 on control panel | Check for a possible fault condition; if none, check fault monitors S1 through S4 and fault breaker CB12 for improper wiring |
| Engine starts but stops after running several seconds | Relay K12 not good | Check relay K12 per Checkout [H] and replace if bad |
| Engine starts but stops after running several seconds | DC control breaker trips after generator set is started | Check all B+ wiring for shorts to ground |
| Engine starts but stops after running several seconds | S6 power latch switch not closing or K1 solenoid rod not adjusted to correct length to allow the hold-in coil of K1 to latch | Check for closing of S6 power latch switch; if switch is OK, check mechanical adjustment of K1 solenoid: is rod adjusted to correct length to allow the hold-in coil of K1 to latch; if K1 adjustment is OK and problem remains, replace engine monitor PC board; check fuel solenoid adjustment |
| No AC output voltage at rated engine RPM | Load circuit breakers open | Locate cause of overload and correct as required; reset breaker, or replace if bad |
| No AC output voltage at rated engine RPM | Circuit open between brush block and voltage regulator | Check continuity of circuit breakers and replace if necessary; check for continuity and correct if circuit is open |
| No AC output voltage at rated engine RPM | Brushes stuck in holder or not making good contact with slip rings | Release brushes if jammed in holder; clean slip rings if dirty |
| No AC output voltage at rated engine RPM | Opens or grounds in rotor or stator | Test continuity of rotor, stator per Tests [B], [C]; replace component if defective |
| No AC output voltage at rated engine RPM | Incorrect field voltage | Test field voltage per TEST [A]; perform TEST [D] |
| No AC output voltage at rated engine RPM | F1 and F2 leads installed on incorrect terminals | Connect brush leads to correct terminals |
| Unstable voltage, engine speed stable | Broken wires or loose connections on voltage regulator assembly | Repair wiring or replace as required |
| Unstable voltage, engine speed stable | Wiring harness from regulator assembly to end bell faulty | Check wiring harness from regulator assembly to end bell per TEST [F]; repair as required |
| Unstable voltage, engine speed stable | Brushes not OK | Inspect brushes per procedure in Manual Section 4; repair or replace as required |
| Unstable voltage, engine speed stable | Voltage regulator faulty | Replace the voltage regulator per procedure [E] |
| Output voltage too high or too low | Engine not running at correct RPM | Set RPM per instructions in appropriate engine manual |
| Output voltage too high or too low | Voltage Adjust control on the regulator board not adjusted correctly | Set control per Voltage Adjustment [G] |
| Output voltage too high or too low | Voltage regulator connections not secure | Check that voltage regulator connections are secure |
| Output voltage too high or too low | Generator set output leads not properly connected | See TEST [H] |
| Output voltage too high or too low | Bad voltage regulator indicated by correctly functioning rotor/stator | Perform procedure [D]; if correctly functioning rotor/stator indicates a bad voltage regulator, replace it per procedure [E] |
| Output voltage too high or too low | Set AC output overloaded | Remove part of the set load |
| Unbalanced generator set output voltage | Load at generator set terminals causing unbalance | Remove load at generator set terminals |
| Unbalanced generator set output voltage | Generator set leads not connected and grounded properly | Check for correct grounding of generator set and load; correct as necessary |
| Unbalanced generator set output voltage | Generator set stator winding not continuous | Replace stator assembly |
| Unbalanced generator set output voltage | Load ground faults | Check load for ground faults and correct as necessary |
Fault codes and symptom→remedy steps extracted from this engine’s service/owner documentation; verify against the official manual before servicing.
Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan HDKAS.
Step-by-step procedures compiled from the Cummins/Onan service manual for this engine.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Air cleaner dust cap | Check | 50 hr | Clean if required; footnote 3: perform more often in extremely dusty conditions | |
| Air cleaner dust cap | Clean | 8 hr | Clean if required; perform more often in extremely dusty conditions (table footnote 3) | |
| Coolant level | Check | 8 hr | Keep recovery tank level between COLD and HOT | |
| Engine oil | Check | 8 hr | Daily or after 8 hours | |
| Engine oil level | Check | 8 hr | 0 mo | Keep oil level between FULL and ADD |
| Fuel level | Check | 8 hr | Every Day/8 Hrs | |
| Generator set | Inspect | 8 hr | Footnote 1: check for oil, fuel, cooling and exhaust system leaks; check exhaust audibly and visually with set running | |
| Genset | Inspect | 8 hr | Every Day/8 Hrs; check for oil, fuel, coolant and exhaust system leaks | |
| Oil level | Check | 8 hr | Every Day/8 Hrs | |
| Battery charging system | Check | 100 hr | Weekly or after 50 hours | |
| Battery specific gravity | Check | 100 hr | Weekly or after 50 hours | |
| Drive belt tension | Check | 100 hr | Visually check belts for evidence of slippage (table footnote 4) | |
| Engine oil | Change | 50 hr | First service — Break-in: change engine oil after the first 20-50 hours of operation (RV QG/RV QG RM); perform at least once a year | |
| Genset service (first service interval, all models) | Other | 50 hr | First service — First service interval is 50 hours for all models. | |
| Air Cleaner Dust Boot | Clean | 100 hr | 1 mo | Perform more often in dusty conditions (footnote 5) |
| Air cleaner element | Clean | 100 hr | ||
| Antifreeze | Check | 250 hr | 6 mo | Monthly or after 100 hours |
| Battery | Check | 100 hr | 1 mo | See battery manufacturer's recommendations (footnote 2) |
| Fuel filter water/sediment | Drain | 250 hr | Monthly or after 100 hours | |
| V-belt tension | Check | 250 hr | 6 mo | Every Month/100 Hrs; check for slippage |
| Water in fuel | Drain | 250 hr | 6 mo | Every Month/100 Hrs; drain about one cup to remove water and sediment |
| Air Filter Element | Replace | 150 hr | Every 150 hours, more often in dusty conditions | |
| Engine Oil and Filter | Change | 1000 hr | First service — Perform more often in dusty conditions; more often in hot weather; at least once a year | |
| Genset service | Other | 250 hr | First service — GEN TYPE QD 7.5/8 (Quiet Diesel 7.5/8 kW; model HDKAx) | |
| Genset service — GEN TYPE GAS RV (Camp Power) | Other | 150 hr | EC-30 service hour meter interval | |
| Genset service — GEN TYPE GAS/LP (Marquis, Microlite, Micro Quiet) | Other | 150 hr | EC-30 service hour meter interval | |
| Genset service — GEN TYPE QD 5.5 (Quiet Diesel; model HDKBx) | Other | 150 hr | EC-30 service hour meter interval | |
| Genset service — GEN TYPE QD 6/8 (Quiet Diesel; model HDKAx) | Other | 150 hr | EC-30 service hour meter interval | |
| Anti-freeze | Check | 250 hr | ||
| Crankcase oil and filter | Change | 250 hr | 6 mo | First service — Perform after first 35 hours of operation on new genset; change crankcase oil every 50 operating hours in extremely dusty conditions |
| Fuel filter element | Change | 500 hr | 12 mo | 6 months or after 250 hours |
| Fuel shut-off linkage | Check | 500 hr | 12 mo | 6 months or after 250 hours |
| Fuel tank sediment | Drain | 250 hr | 6 mo | Footnote 5: drain one cup of fuel to remove water and sediment |
| Generator assembly | Clean | 250 hr | 6 mo | Clean the generator set at least every six months |
| Generator set brushes | Check | 250 hr | 6 mo | Brushes inspected for wear and cleaning every six months |
| Genset service — GEN TYPE QD 10/12 (Quiet Diesel; models HDCAx, HDKCx) | Other | 250 hr | EC-30 service hour meter interval | |
| Water/sediment from fuel filter | Drain | 250 hr | 6 mo | |
| Air Cleaner Element | Change | 500 hr | 12 mo | Perform more often in dusty conditions (footnote 5) |
| Coolant Anti-freeze Protection | Check | 1000 hr | 1 mo | Perform at least once a year |
| Coolant Anti-freeze Protection | Test | 500 hr | Check Coolant Anti-freeze Protection |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Bore | 2.64 inch (67 mm) | inch (mm) | |
| Clearance | Clearance to top of genset compartment | 1 | inch (25.4 mm) | minimum, including acoustic insulation |
| Clearance | Compartment opening free area, generator end | 200 | square inches | minimum |
| Clearance | Exhaust system distance from combustible material | 3 | in | |
| Clearance | Fan belt deflection | 0.4 (10 mm) | inch | 22 pounds (10 kg) finger pressure at middle of belt |
| Clearance | Genset to bulkhead/other equipment (pusher/suction fan) | 6 | inches (152 mm) | minimum |
| Clearance | Minimum clearance between genset and compartment insulation | 1 | in | |
| Clearance | Minimum clearance exhaust system to combustible material | 3 | in | |
| Clearance | Minimum space between engine exhaust components and compartment insulation | 3 | in | |
| Clearance | Muffler/tailpipe to combustible material | 3 | inches (76 mm) | minimum, unless insulated or shielded |
| Clearance | Stroke | 2.68 inch (68 mm) | inch (mm) | |
| Clearance | V-belt deflection | 0.4 | inch | with 20 pounds (10 kg) applied to middle of pulley span (10 mm) |
| Clearance | V-belt deflection at 20 pounds (10 kg) applied to middle of pulley span | 0.4 inch (10 mm) | inch | at 20 lbs (10 kg) |
| Current | Battery charging DC alternator output | 30 | amp | |
| Current | Starter motor draw at 12 VDC | 100 | A | |
| Gap | Fan belt deflection | 0.4 | inch (10 mm) | 22 pounds (10 kg) finger pressure at middle of belt |
| Gap | Fan belt deflection at middle of belt | 0.4 | inch (10 mm) | finger pressure of 22 pounds (10 kg) |
| Other | AUTO GEN disabled if safety input not verified | 30 | days | |
| Other | Actuator speed control lever stop screw (beginning Spec B) | Turn in until just makes contact, then one more full turn (rotor not in place); set locknut | Adjust whenever a different actuator base assembly is installed | |
| Other | Altitude power derate | approximately 3 percent per 1000-foot (305 m) increase in elevation | percent | |
| Other | Battery cable size, total cable length 0 to 10 feet (0 to 3 m) | 2 | AWG | temperatures down to –20°F (–29°C) |
| Other | Battery cable size, total cable length 11 to 15 feet (3 to 4.5 m) | 0 | AWG | temperatures down to –20°F (–29°C) |
| Other | Battery cable size, total cable length 16 to 20 feet (4.5 to 6 m) | 000 | AWG | temperatures down to –20°F (–29°C) |
| Other | Battery compartment ventilation opening | 1.7 | in2 | minimum at top and bottom |
| Other | Battery compartment ventilation opening | 11 | cm2 | minimum at top and bottom |
| Other | Battery electrolyte specific gravity (fully charged) | 1.260 | at approximately 80°F (27°C) | |
| Other | Battery electrolyte specific gravity, charge if below | 1.215 | specific gravity | |
| Other | Battery electrolyte specific gravity, fully charged | 1.260 | specific gravity | at 80 F (27 C) |
| Other | Battery rating | 425 | CCA | |
| Other | Battery rating | 625 | CCA | below 32°F (0°C) |
| Other | Battery recharge threshold (charge if specific gravity less than) | 1.215 | specific gravity | |
| Other | Battery specific gravity charge threshold | 1.215 | charge battery if specific gravity is less than this | |
| Other | Battery specific gravity, fully charged | 1.260 | at 80°F (27°C) | |
| Other | Bore | 2.64 | inch (67 mm) | |
| Other | Bore | 2.99 (76) for HDKAL/HDKAQ; 2.83 (72) for HDKAR/HDKAS | in (mm) | |
| Other | Bore | 72 | mm | |
| Other | Bore | 76 | mm | |
| Other | Brush wear limit (wire inserted into brush holder) | 1 | inch (25 mm) | replace brush and spring if wire enters holder this far or more |
| Other | Circuit breaker rating | 35 | A | 2 pole, 60 Hz |
| Other | Clamping screw (beginning Spec B high-idle adjustment) | Run back in by hand until snug, back it out 1-1/2 turns, set lock nut | turns | After setting high-idle speed |
| Other | Compartment depth | 25 | in | |
| Other | Compartment height | 25 | in | |
| Other | Compartment width | 38.4 | in | |
| Other | Compression Ratio | 23 : 1 | ||
| Other | Compression ratio | 23 to 1 | ||
| Other | Compression ratio | 23:1 | ||
| Other | Continuous operation at up to 80 percent of maximum power | 6000 | watts | 80% of maximum power |
| Other | Cooling air requirement - Generator Inlet | 100 | in2 | |
| Other | Cooling air requirement - Radiator | 200 | in2 | |
| Other | Cooling system capacity | 4.2 quart (4 l) | quart (l) | includes coolant recovery tank |
| Other | Cooling system capacity | 4.73 | L | |
| Other | Cranking time that triggers fault | 35 | seconds | cranking time exceeded fault (4 blinks) |
| Other | Cranking time that trips fault code 4 | 35 | seconds | |
| Other | Cyclic horizontal forces | ±500 | lbs | ±1 g-force |
| Other | Cyclic vertical forces | ±1500 | lbs | ±3 g-force |
| Other | DC alternator output | 30 | amp | 12 Volt Battery Charging |
| Other | Dimensions L x W x D | 80.98 x 130.12 x 30.48 | mm (3.188 x 5.125 x 1.20 inches) | |
| Other | Displacement | 1001 | cm3 | |
| Other | Displacement | 44 | inch3 (719 cc) | |
| Other | Displacement | 44 inch3 (719 cc) | inch3 (cc) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | 50/50 ethylene glycol antifreeze and water | 4.2 quarts (4 liters) | Provides protection to -34°F (-37°C). Use distilled water if available. Replace every 2 years. | ||
| Coolant | 50/50 ethylene glycol based antifreeze and water | Mix thoroughly before adding; use clean soft tap water, distilled water or pure rain; select high quality antifreeze with corrosion inhibitors | |||
| Coolant | 50/50 mixture ethylene glycol anti-freeze and water | Contains rust and corrosion inhibitor; no stop-leak additive | above -37°C | 4.0 l | 4.2 quart (4 l) capacity; suitable down to -34 F (-37 C) |
| Coolant | 50/50 mixture of ethylene glycol anti-freeze and water | Reliable brand with rust and corrosion inhibitor; must not contain stop-leak additive | above -37°C | 50/50 provides freeze protection to -34 F (-37 C); use distilled or soft water | |
| Coolant | 50/50 mixture of ethylene glycol anti-freeze and water as shipped; use ethylene or propylene glycol anti-freeze solution containing rust and corrosion inhibitor | Anti-freeze must not contain a stop-leak additive; water must be clean, low in minerals and free of corrosive chemicals; use distilled water if available | above -37°C | 4.0 l | Factory fill suitable down to -34 deg F (-37 deg C); cooling system capacity 4.2 quart (4 l) includes coolant recovery tank; replace coolant every two years |
| Coolant | 50/50 mixture of ethylene glycol anti-freeze and water; ethylene or propylene glycol solution containing rust and corrosion inhibitor | No stop-leak additive; use clean, low-mineral water, distilled if available | above -37°C | 4.0 l | Suitable for temperatures down to -34° F (-37° C); cooling system capacity 4.2 quart (4 l) including coolant recovery tank; replace coolant every two years |
| Coolant | 50/50 mixture of ethylene glycol antifreeze and water | above -37°C | 4.0 l | Suitable for temperatures down to –37 °C (–34 °F); antifreeze should be fully formulated with rust inhibitors and coolant stabilizers, mixed with fresh (distilled) water | |
| Coolant | 50/50 mixture of water and ethylene glycol | above -37°C | Best quality ethylene or propylene glycol antifreeze fully formulated with rust inhibitors and coolant stabilizers, but not stop-leak additives. Use fresh water low in minerals; distilled water is best. Shipped 50/50 mixture good for -34 F (-37 C). | ||
| Coolant | 50/50 mixture of water and ethylene glycol (or propylene glycol) antifreeze | Fully formulated with rust inhibitors and coolant stabilizers but not with stop-leak additives; use fresh water low in minerals, distilled best | above -37°C | 4.73 L | Shipped with recommended 50/50 mixture, good for -34 F (-37 C); cooling system capacity 1.25 gal (4.73 L) |
| Coolant | Ethylene or propylene glycol anti-freeze, 50/50 mixture | above -34°C | 4.2 quart | Must contain rust and corrosion inhibitor; no stop-leak additives | |
| Coolant | 50/50 mixture of water and ethylene glycol (best quality ethylene or propylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizers, no stop-leak additives) | above 37°C | 4.73 L | Good for -34°F (-37°C); Cooling System Capacity 1.25 gal (4.73 L); use distilled water; replenish recovery tank between COLD and HOT | |
| Coolant | Ethylene glycol antifreeze, fully formulated with rust inhibitors and coolant stabilizers | above 37°C | 4.0 l (4.2 qt) incl. recovery tank | 50/50 mixture recommended for all climates | |
| Engine oil | CH-4, CG-4, or CF-4 | API performance class | 3.0 quarts (2.6 liters) | May be combined with SJ, SH, or SG. Select viscosity grade per Chart 1 based on ambient temperature. | |
| Engine oil | SAE 10W-30 / 10W-40 / 0W-30 / 5W-30 | Use viscosity chart to select grade for expected ambient temperature range; avoid mixing grades or brands | |||
| Engine oil | SAE 15W-40 | API CF, CF-4, CG-4, CH-4, CI-4 or CJ-4 (diesel) | OnaMax 15W-40 #326-5336; multi-grade recommended year-round in liquid-cooled engines; synthetic oil not recommended | ||
| Engine oil | SAE 15W-40 multi-grade recommended for year-round use | API Class CF-4 or CF or better | 4.7 L | Pre-start checks state engine oil capacity 4.7 liters (5 quarts); Specifications state lubricating oil capacity with oil filter 6.0 liters (6.34 quarts). Choose viscosity grade per ambient temperature before next oil change. | |
| Engine oil | SAE 15W-40 multi-grade recommended for year-round use (choose viscosity grade per ambient temperature chart, Figure 2) | API Class CG-4, CF-4, CF or better | 4.1 L | Lube oil capacity 4.34 qt (4.1 L) including filter | |
| Engine oil | SAE 15W-40 multi-grade recommended for year-round use; choose viscosity grade for ambient temperature range before next oil change | API Class CF-4 or CF or better | 5.1 L | Lube Oil Capacity 5.39 qt (5.1 L); see Figure 2 SAE viscosity grade vs ambient temperature | |
| Engine oil | SAE viscosity grade chosen from Chart 1 (Oil Viscosity vs. Temperature) for ambient temperatures expected until next oil change | API performance Class CH-4, CG-4 or CF-4, may be in combination with SJ, SH or SG (e.g. CH-4/SJ) | 2.6 l | 3 quart (2.6 l) with filter | |
| Engine oil | SAE viscosity grade per Chart 1 (Oil Viscosity vs. Temperature) | API CH-4, CG-4 or CF-4 (may combine with SJ, SH or SG) | 2.6 l | 3 quarts (2.6 l) capacity with filter | |
| Engine oil | SAE viscosity grade per Chart 4-1 (oil viscosity vs. temperature) | API performance Class CH-4, CG-4 or CF-4D, may be combined with SJ, SH or SG (e.g. CH-4/SJ) | 2.6 l | Oil capacity with filter 3 quart (2.6 l) | |
| Engine oil | SAE viscosity grade per engine lubrication section | API classification per engine lubrication section | Refer to Engine Workshop Manual for oil recommendation | ||
| Engine oil | SAE viscosity grade selected per anticipated ambient temperature (Chart 1, Oil Viscosity vs. Temperature) | API performance Class CH-4, CG-4 or CF-4, may be in combination with performance Class SJ, SH or SG (e.g. CH-4/SJ) | 3.0 quart (2.6 l) | Oil capacity with filter; change oil if not appropriate for ambient temperatures during break-in | |
| Engine oil | SAE viscosity per anticipated ambient temperature (Table 1, Oil Viscosity vs. Temperature) | API classification CC and later | 4.26 liters (4.5 quarts) | Do not use synthetic oil or non-detergent oil. Do not mix different brands of oil. (Specifications section lists lube oil capacity 4.5 qt (4.25 L) including filter.) | |
| Engine oil | SAE-30 | API SJ, SL or SM (gasoline) | OnaMax SAE-30 #326-5339; preferred summer grade for optimum oil consumption control in air-cooled engines | ||
| Engine oil | Performance Class CH-4, CG-4 or CF-4 | -40°C to 40°C | 3.0 quart | Select SAE grade based on ambient temperature; see oil viscosity chart | |
| Engine oil | API Class CH-4, CG-4, or CF-4 | SAE viscosity grade based on ambient temperature | above -34°C | 2.6 l | See Chart 1 for viscosity selection by temperature |
| Engine oil | 5W-30 | API CF, CF-4, CG-4, CH-4, or CI-4 | -28°C to 10°C | ||
| Engine oil | 10W-30 10W-40 | API CF, CF-4, CG-4, CH-4, or CI-4 | -18°C to 27°C | ||
| Engine oil | 15W-40 (OnaMax) | API CF, CF-4, CG-4, CH-4, or CI-4 | -12°C to 38°C | Multigrade oils such as SAE 15W-40 are recommended for year round use |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 1 | Engine Over Temperature | Engine coolant temperature exceeded 115°C (239°F) for 10 seconds | Shutdown | Check coolant level and add if needed; check for blockages/dirt on radiation fins; reduce load |
| 1, 2, 3, 4 | First level faults | First-level faults; avoid interpreting as second-level codes 11, 22, 33, or 44 | Shutdown | Pay close attention to the pause sequence |
| 2 | Low Oil Pressure | Low oil pressure cutoff switch did not open | Shutdown | Check engine oil level, add or drain as needed |
| 3 | Service Check | Second-level service fault; flash STOP/PRIME once for 2-digit code | Warning | See second-level fault code |
| 4 | Over Crank | Cranking exceeded 30 seconds without engine starting | Shutdown | Check fuel level and prime; check air filter; replace oil with proper viscosity; check fuel fittings; replace fuel filter |
| 4 blinks | Cranking time exceeded 35 seconds | Status indicator light repeatedly blinks four times | Shutdown | Check fuel supply and priming before re-cranking |
| 8 | Cranking Fault | Starter or cranking circuit malfunction | Shutdown | Contact authorized Onan dealer |
| 11 | Overload Fault | Genset is overloaded | Shutdown | Reduce electrical load |
| 12 | Over Voltage | Control unable to maintain rated voltage | Shutdown | Contact local dealer or distributor |
| 13 | Under Voltage | Control unable to maintain rated voltage | Shutdown | Reduce load (air conditioners, battery chargers) |
| 14 | Over Frequency | Engine governor unable to maintain rated frequency | Shutdown | Contact local dealer or distributor |
| 15 | Under Frequency | Engine governor unable to maintain rated frequency | Shutdown | Reduce load |
| 17 | Fuel Pump Fault | Controller sensed open circuit; bypassable fault prior to Spec F, discontinued beginning Spec F | Shutdown | Try priming by holding control switch at Stop; reconnect fuel pump leads; test pump on 12 V battery; check P1-2/E2-1 and E2-2/ground continuity. |
| 18 | Glow Plug Circuit Protection Fault | Controller sensed short circuit; bypassable fault prior to Spec F, discontinued beginning Spec F | Shutdown | Reconnect HR-1 to glow plug bus bar; check HR-1 and A1-J8 for continuity to ground; replace engine harness or controller assembly. |
| 19 | Governor Actuator | Control sensed an open or shorted circuit | Shutdown | Contact local dealer or distributor |
| 21 | Starter Solenoid Circuit Protection Fault | Controller sensed short circuit; discontinued beginning Spec F | Shutdown | Reconnect K-1 to starter solenoid; test solenoid and starter; reconnect A1-J6; check continuity to ground; replace controller assembly. |
| 22 | Governor Actuator Overload | Duration of operation near full-duty cycle beyond design limit | Shutdown | Reduce load; check air filter; check exhaust system for blockage |
| 23 | High Engine Temperature Fault | Engine temperature exceeds limit | Shutdown | Check coolant level and allow engine to cool |
| 24 | Throttle Control Fault | Engine throttle control malfunction | Shutdown | Contact authorized Onan dealer |
| 25 | Engine Sensor Fault | Engine sensor malfunction or reading error | Shutdown | Contact authorized Onan dealer |
| 26 | ENGINE BELOW SPEED TARGET | Governor unable to regulate to target speed | Shutdown | Reduce connected load; prime fuel system |
| 27 | Voltage Sense | Control unable to sense output voltage | Shutdown | Contact local dealer or distributor |
| 28 | DC SENSE LOST | Controller unable to sense DC bus voltage | Shutdown | Open circuit breaker; disconnect excessive loads before starting |
| 29 | High Battery Voltage | Voltage across battery system greater than 19 Volts | Shutdown | Check battery bank connections (parallel 12V not series 24V); select lower boost charge rate |
| 31 | Overspeed Fault | Engine speed exceeds 3600 rpm | Shutdown | Contact authorized Onan dealer |
| 32 | Low Cranking Speed | Cranking speed less than 180 RPM for more than 2 seconds | Shutdown | Clean/tighten battery connections, recharge/replace battery; replace engine oil with proper viscosity |
| 33 | HIGH ENGINE COOLANT TEMPERATURE | Engine coolant temperature exceeded design limit | Shutdown | Check coolant level and leaks; remove blockages; reduce load; clean cooling system |
| 34 | HIGH INVERTER TEMPERATURE | Inverter heat sink temperature exceeded design limit | Shutdown | Remove blockages from air openings; reduce connected appliances |
| 35 | Control Card Failure | Microprocessor EEPROM error during self test | Shutdown | Contact local dealer or distributor |
| 36 | Engine Stopped | Engine stopped without receiving command from control | Shutdown | Check fuel level and prime; check air filter; check for mechanical damage |
| 37 | INVALID GENSET CONFIGURATION | Genset configuration preprogrammed at factory | Shutdown | See an authorized Onan dealer |
| 38 | Over Current (Field Overload) | Low power factor loads | Shutdown | Reduce load; check appliances for proper operation |
| 39 | Low Battery Voltage Fault | Battery voltage dropped below 9 volts while genset running; discontinued beginning Spec F | Warning | Clean and tighten battery cable connections; avoid running genset while cranking the vehicle engine where genset batteries supplement vehicle batteries. |
| 41 | Generator Rotor | Control unable to sense field or output voltage | Shutdown | Contact local dealer or distributor |
| 42 | Processor | Microprocessor ROM error during self test | Shutdown | Contact local dealer or distributor |
| 43 | Processor | Microprocessor RAM error during self test | Shutdown | Contact local dealer or distributor |
| 44 | Not assigned | Second-level code 44 has not been assigned a fault | ||
| 45 | Speed Sense | Control unable to sense quadrature frequency | Shutdown | Contact local dealer or distributor |
| 46 | INVERTER POWER SUPPLY FAULT | Low battery voltage or power supply device failure | Shutdown | Avoid running genset during vehicle engine cranking; clean battery connections; recharge battery |
| 48 | Generator Field Sense | Control unable to sense field voltage | Shutdown | Contact local dealer or distributor |
| 57 | Over Prime | Priming exceeded 3 minutes | Shutdown | Check control switch; remove any object holding switch in STOP/PRIME position |
| restore | Restoring fault code blinking | Fault code stops blinking after five minutes | Info | Press Stop three times within three seconds to restore fault code blinking |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
⚠ Accidental starting can cause severe personal injury or death. Disconnect the negative (−) cable(s) at the battery(ies) before working on the genset.
⚠ Do not operate the generator set without the belt guard in place.
⚠ Stop the set and disable by disconnecting battery cables before service.
⚠ Do not let engine speed exceed 3600 RPM.
Tools: tachometer
⚠ GEN TYPE sets the service interval for service messages and critical automatic starting parameters.
⚠ QUIET ON mode prohibits the genset from automatically starting between the start and end of Quiet Time.
⚠ If it has not been setup (SafeType NONE), automatic operation will not be allowed.
⚠ ENTER to unlock prevents unauthorized changes to the hour-meter.
⚠ Touching uninsulated live parts can cause severe injury or death.
Tools: voltmeter
⚠ Do not change the 50/60 Hz setting on the regulator.
⚠ The V/Hz Break Point pot is factory set and sealed; do not adjust.
Tools: flat-blade screwdriver, voltmeter
⚠ Disconnect both battery cables, negative (-) cable first, when repairs are made.
⚠ Contact with high voltage can cause severe personal injury or death.
Tools: Voltmeter, Flat-blade screwdriver
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| AC Present + positive | #14 | Positive input for shore AC present sensing; do not connect 120VAC or 240VAC line voltage. | ||
| AC Present - ground | #13 | Supplied by UL Listed 120VAC to 12-16VAC transformer, or the 12VDC ground side of a UL Listed 120VAC to 12VDC plug-in power supply. | ||
| Battery Ground (Negative) | Wire #1 | Supplies ground/negative side of the circuit for the EC-20; must be supplied from the genset. | ||
| Battery ground (negative) | #1 | Supplies the ground or negative side of the circuit for the EC-30; must be supplied from the genset. | ||
| Genset Status Light | Wire #6 | Diagnostic output from the genset that flashes the red light in the START/STOP switch; decoded by the EC-20 to display a text fault message. | ||
| Genset status light | #6 | Diagnostic output that flashes the red light in the START/STOP switch to indicate a genset fault; decoded to a text fault message. | ||
| Not Used | Wire #4 | |||
| Start/Preheat | Wire #3 | Supplies start/preheat signal to the genset; controlled by the STOP/START switch and in automatic mode by the EC-20. | ||
| Start/preheat | #3 | Supplies the start/preheat signal to the genset; controlled by the STOP/START switch and, in automatic mode, by the EC-30. | ||
| Stop Output | Wire #2 | Active low or grounded output supplying the stop signal to the genset; controlled by the STOP/START switch. | ||
| Stop output | #2 | Active low or grounded output to the genset; controlled by the STOP/START switch and, in automatic mode, by the EC-30. | ||
| Switched B+ From Genset | Wire #5 | Switched to battery positive when the genset is running; provides genset hour-meter and running signal. | ||
| Switched B+ from genset | #5 | Switched to battery positive voltage when the genset is running; provides genset hour meter and running indication. | ||
| single | Quadrature power connection Q60 - 60 Hz, Q50 - 50 Hz units | Q1, Q50, Q60 | Note 2: Quadrature power connection Q60-60 Hz, Q50-50 Hz units. Note 3: AVR reference voltage. Note 1: From J2-15 for field flashing. | |
| 100 | 1 | Reconnection chart | ||
| 100 | 1 | reconnection chart | ||
| 100 | single | reconnection chart | L0 | |
| 100 | single-phase | 50 Hz; see reconnection chart | ||
| 100 | single-phase | L0, L1 | T4, T3, L2, L1, Q50, Q60, T2, T1, S2, 2, S1, Q1 | |
| 100/200 | 1 | Reconnection chart | Wiring diagram 612-6637 reconnection chart | |
| 100/200 | 1 | reconnection chart | ||
| 100/200 | single | As shown | T1, T2, T3, T4; L0(N), L1 | 100/200 volts only; stator resistance values differ (T1-T2, T3-T4: 0.150 ohm; Q1-Q60: 2.3 ohms) |
| 100/200 | single | reconnection chart | L0, L1 | |
| 100/200 | single-phase | 50 Hz; see reconnection chart | ||
| 100/200 | single-phase | L0(N), L1 | Q50, Q60, T2, T1, S2, 2, S1, Q1 | 50 Hz |
| 110 | 1 | reconnection chart | T4, T3; L1 | |
| 110 | single-phase | L0, L1 | T4, T2, T3, T1, L0 | |
| 110/190 | 3 | 50 HZ CODE Z | T1-T12 | |
| 110/220 | 1 | As shown | T1, T2, T3, T4 | See reconnection chart for other voltages |
| 110/220 | 1 | reconnection chart | T4, T3, T2, T1; L2, L1, L0(N) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
The Cummins/Onan HDKAS engine has an oil capacity of 4.5 liters.
The Cummins/Onan HDKAS has a displacement of 0.898 liters with 3 cylinders.
The Cummins/Onan HDKAS powers 1 generator set(s), including Cummins/Onan HDKA.
A commonly reported issue on generators using the Cummins/Onan HDKAS is: Engine does not crank. Cause: Faulty remote circuit. Fix: Try starting at the genset control panel. If the genset starts, have the remote circuit repaired as necessary..