Home›Repair guides›Cummins/Onan›Generator Set Storage (Out-of-Service Protection)

Cummins/Onan — Generator Set Storage (Out-of-Service Protection)

Maintenance

From a Cummins/Onan owner's manual — check it applies to your exact model before use.

Applies to: Cummins/Onan HDKA, Cummins/Onan HDKAQ, Cummins/Onan HDKAR

Before you start

  • Battery electrolyte can cause severe eye damage and burns to the skin.

Procedure

  1. Exercise the genset until the engine is at operating temperature.
  2. Shut down and disconnect the battery cables (negative first); store the battery in a cool, dry place and trickle-charge every 30 days.
  3. Drain the crankcase oil while still warm; replace the oil filter; refill and attach a tag indicating oil viscosity.
  4. Check the coolant level and add more if low; test the coolant mixture if freezing temperatures are possible.
  5. Plug exhaust outlets to prevent entrance of moisture, bugs and dirt.
  6. Clean and wipe the entire genset; lightly coat parts that may rust with grease or oil.

Specs & values

  • No. 2 diesel fuel protects cylinders at least 30 days; for storage longer than 30 days follow this procedure

Full service-parts list: Cummins/Onan HDKA →, Cummins/Onan HDKAQ →, Cummins/Onan HDKAR →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →