Home›Repair guides›Magnum›AUTO (Remote) Starting of the Generator

Magnum — AUTO (Remote) Starting of the Generator

Operation

From a Magnum operator's manual covering: MMG35D, MMG45K, MMG55D. Check it applies to your exact model before use.

Applies to: Magnum MMG35D, Magnum MMG45K, Magnum MMG55D, John Deere PE4024TF281 engine, Kubota V3600-T-E3BG engine, John Deere 4024HF285 engine

Before you start

  • Verify contacts on any remote switch are OPEN before pressing AUTO.

Procedure

  1. Perform a manual start at least once to verify engine operation.
  2. If checking the remote start circuit, remove wires from the remote start terminal block.
  3. Press the AUTO button; LCD highlights AUTO.
  4. Attach a jumper wire (minimum 16 gauge) across the two remote start terminals.
  5. Engine should crank, start and run.
  6. Remove the jumper wire; engine will stop. Reconnect transfer switch wires.
  7. Close the main circuit breaker (ON/I).
  8. Secure the generator by closing and locking all access doors.

Tools required

  • Jumper wire, minimum 16 gauge Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Remote start closure applies a ground to the MDC

Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.