Magnum — AUTO (Remote) Starting of the Generator
Operation
From a Magnum operator's manual covering: MMG35D, MMG45K, MMG55D. Check it applies to your exact model before use.
Applies to: Magnum MMG35D, Magnum MMG45K, Magnum MMG55D, John Deere PE4024TF281 engine, Kubota V3600-T-E3BG engine, John Deere 4024HF285 engine
Before you start
- Verify contacts on any remote switch are OPEN before pressing AUTO.
Procedure
- Perform a manual start at least once to verify engine operation.
- If checking the remote start circuit, remove wires from the remote start terminal block.
- Press the AUTO button; LCD highlights AUTO.
- Attach a jumper wire (minimum 16 gauge) across the two remote start terminals.
- Engine should crank, start and run.
- Remove the jumper wire; engine will stop. Reconnect transfer switch wires.
- Close the main circuit breaker (ON/I).
- Secure the generator by closing and locking all access doors.
Tools required
- Jumper wire, minimum 16 gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Remote start closure applies a ground to the MDC
Source: Magnum operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.