The Kubota V3600-T-E3BG is a 3.6 L turbocharged engine rated at 1800 rpm. It powers generator sets from Generac and Magnum, including the MMG45FHK, MMG45FHKCAN6 and MMG45K. It holds 13.2 L (3.5 gal) of oil and 16.6 L (4.4 gal) of coolant.
Also known as: Kubota V3600-T-E3BG
Part of the Kubota V3600-T engine family — 2 variants share parts & fitment.
| Oil capacity | 13.2 L |
|---|---|
| Coolant capacity | 16.6 L |
| Displacement | 3.6 L |
| Aspiration | turbocharged |
| Rated speed | 1800 rpm |
Shared across brands: Generac, Magnum
Compiled from service & troubleshooting documentation across every generator set that uses the Kubota V3600-T-E3BG.
| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Engine oil and oil filter | Change | 100 hr | First service — Kubota: change after the initial 50 hours of operation, then at the appropriate interval thereafter | |
| Oil filter cartridge | Replace | 50 hr | First service — Kubota engine schedule (initial 50 hours, then at appropriate interval) | |
| Maintenance reminder (Time to Service) | Other | 250 hr | WrnMaintenance set at 250 hours of engine running time | |
| Wheel bearings, trailer | Lubricate | 12 mo | Minimum recommended lubrication every 12 months or 12,000 miles (19,312 km) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Other | Altitude derating | 2-4 | % per 1000 ft (305 m) | plus 1% per 10°F (3-5°C) above 72°F (22.2°C) |
| Other | Fuel level shut down setpoint | 5 | % | Sd Fuel Level setpoint |
| Other | Fuel level warning setpoint | 15 | % | Wrn Fuel Level setpoint |
| Other | Maintenance (Time to Service) interval | 250 | hours | engine running time |
| Other | Starter cool-down after failed crank | 120 | seconds | minimum two minutes before repeating start sequence |
| Other | V Detect time delay | 45 | seconds | before controller records generator nominal output voltage |
| Other | Voltage tolerance vs. selector switch setting | 10 | % | greater deviation causes shut down |
| Pressure | Engine oil pressure (normal operating) | 35-80 | psi | (241-552 kPa) |
| Pressure | Engine oil pressure shut down setpoint | 20 | psi | (138 kPa) engine controller shuts engine down below this |
| Pressure | Oil pressure after restart | 5 | psi | must read within five seconds (34 kPa) |
| Pressure | Oil pressure display range | 0-100 | psi | (10-689 kPa) |
| Speed | Engine operating speed | 1800 | rpm | |
| Speed | Generator output frequency (no load) | 60 | Hz | no loads connected |
| Temperature | Ambient air temperature maximum for operation | 120 | °F | (49°C) |
| Temperature | Coolant temperature display minimum | 100 | °F | (38°C); zero displayed until reached |
| Temperature | Engine coolant temperature shut down | 230 | °F | (110°C) |
| Temperature | Viscous fan clutch temperature range | 170-200 | °F | (77-93°C) varies by unit model |
| Torque | Generator drive plate bolts | 46 | ft-lbs | (49 Nm) |
| Torque | Trailer wheel lug nuts - first pass | 20-25 | ft-lbs | (27-33 Nm) |
| Torque | Trailer wheel lug nuts - second pass | 50-60 | ft-lbs | (67-81 Nm) |
| Torque | Trailer wheel lug nuts - third pass | 90-120 | ft-lbs | (122-162 Nm) |
| Voltage | Battery voltage (engine running, 12 volt systems) | 13-14 | V | engine running |
| Voltage | Battery voltage (engine running, 24 volt systems) | 24-26 | V | engine running |
| Voltage | Voltage regulation | +/- 1 | % |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| AnInIOM Sd | Analog Input IOM Shutdown | Shutdown alarm configurable on the input of IG-IOM/IGS-PTM. | Shutdown | |
| AnInIOM Wrn | Analog Input IOM Warning | Warning alarm configurable on the input of IG-IOM/IGS-PTM. | Warning | |
| Battery Flat | Battery Flat (low battery) | If the controller switches off during starting sequence due to bad battery condition, it doesn't try to start again and activates this protection. | Shutdown | |
| Binary Input | Binary Input | Configurable warning/shutdown alarms on the inputs of IL-NT. | ||
| ChrgAlternFail | Charge Alternator Fail | Failure of the alternator to charge the battery. | Warning | |
| EmergencyStop | Emergency Stop | If the input Emergency Stop is opened or the red E-Stop button is pushed, shutdown is immediately activated. | Shutdown | |
| Engine Temp Sd | Engine Temperature Shutdown | Water temperature is greater than Sd Water Temp setpoint. | Shutdown | |
| Engine Temp Wrn | Engine Temperature Warning | Water temperature is greater than Wrn Water Temp setpoint. | Warning | |
| Fgen<, > | Generator Frequency Out of Limits | The generator frequency is out of limits given by Gen >f and Gen <f setpoints. | Shutdown | |
| Fuel Level Sd | Fuel Level Shutdown | Fuel level is smaller than Sd Fuel Level setpoint (5%). | Shutdown | |
| Fuel Level Wrn | Fuel Level Warning | Fuel level is smaller than Wrn Fuel Level setpoint (15%). | Warning | |
| GCB fail | Generator Circuit Breaker Fail | Failure of the generator circuit breaker. | Shutdown | |
| Igen unbl | Generator Current Unbalanced | The generator current is unbalanced. | Shutdown | |
| Low BackupBatt | Low Backup Battery | RTC backup battery is flat (low). | Warning | |
| Oil Press Sd | Oil Pressure Shutdown | Oil pressure is smaller than Oil Press Sd setpoint. | Shutdown | |
| Oil Press Wrn | Oil Pressure Warning | Oil pressure is smaller than Oil Press Wrn setpoint. | Warning | |
| Overload | Overload | The load is greater than the value given by Overload setpoint. | Shutdown | |
| Overspeed | Overspeed | The protection comes active if the speed is greater than Overspeed setpoint. | Shutdown | |
| ParamFail | Parameter Fail | Wrong checksum of parameters. Happens typically after downloading new firmware or changing of the parameter. The controller stays in INIT mode. Check all parameters, write at least one new parameter. | Check all parameters; write at least one new parameter | |
| PickupFault | Pickup Fault | Failure of the magnetic pick-up sensor for speed measurement. | Shutdown | |
| SPN:100 | EngOil Press | John Deere ECU alarm list parameter (SPN shown as FC on bottom left of LCD). | Refer to John Deere Operator's Manual | |
| SPN:102 | Boost Press | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:105 | Intake Temp | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:110 | EngCool Temp | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:1485 | ECU MainRelay | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:175 | EngOil Temp | John Deere ECU alarm list parameter; oil temp always displays #####. | Refer to John Deere Operator's Manual | |
| SPN:629 | Controller #1 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:636 | PositionSensor | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:637 | TimingSensor | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:651 | InjectorCyl#1 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:652 | InjectorCyl#2 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:653 | InjectorCyl#3 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:654 | InjectorCyl#4 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:655 | InjectorCyl#5 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:656 | InjectorCyl#6 | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| SPN:677 | EngStartRelay | John Deere ECU alarm list parameter. | Refer to John Deere Operator's Manual | |
| Sd IOM fail | IOM Fail | IOM/IGS-PTM module failure. | Shutdown | |
| SprinkIActive | Sprinkler Active | The protection is active if the output Sprinkler is closed. | Warning | |
| Start failed | Start Failed | Unit did not start. | Shutdown | After starter cools two minutes, press FAULT RESET and retry |
| Stop fail | Stop Fail | Unit did not stop. | Shutdown | |
| Ubat | Battery Voltage Out of Limits | Battery voltage is out of limits given by Batt Undervolt setpoints. | Warning | |
| Underspeed | Underspeed | During starting of the engine, when the RPM reaches the value of Starting RPM setpoint, the starter is switched off and the speed of the engine can drop under Start RPM again. Then the underspeed protection becomes active. Protection evaluation starts 5 seconds after start up. | Shutdown | |
| Vgen unbal | Generator Voltage Unbalanced | The generator voltage is unbalanced more than the value of Volt unbal setpoint. | Shutdown | |
| Vgen<, > | Generator Voltage Out of Limits | The generator voltage is out of limits given by Gen <V and Gen <V setpoints. | Shutdown | |
| Wrn ECU Alarm | ECU Alarm Warning | ECU alarm list is not empty. | Warning | View ECU Alarm List; resolve fault and clear code |
| Wrn RA15 fail | RA15 Module Failure Warning | Warning alarm in case of lost connection to IGL=RA15 module. | Warning | |
| WrnMaintenance | Maintenance Warning | The period for servicing is set by the WrnMaintenance setpoint. The protection comes active if the running hours of the engine reach this value. | Warning | Service unit and reset Time to Service to 250 hours |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Tools: Torque wrench
Tools: Grease gun with standard fitting
⚠ An '*' on the LCD means the setpoint cannot be changed without a password. Contact Technical Support.
⚠ Verify contacts on any remote switch are OPEN before pressing AUTO.
Tools: Jumper wire, minimum 16 gauge
⚠ The controller must be in AUTO mode to run at the programmed time.
⚠ Use a trickle battery charger or solarizer to prevent the controller from draining the battery while in AUTO mode.
⚠ CARBON MONOXIDE: USING A GENERATOR INDOORS CAN KILL YOU IN MINUTES!
⚠ NEVER start the unit under load; breakers must be OFF in MANUAL mode.
Tools: Flat head screwdriver
⚠ This check list applies to both manual and remote starting of the generator.
⚠ NEVER tow trailer using defective parts!
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 120 | 3 | Dedicated 12 lead generator - LOW DELTA | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | Wiring block diagram - dedicated 12 lead generators option |
| 208/120 | 3 | 3 Position Voltage Selector Switch - 208/120V 3-PHASE | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | L1-L2=208V, L1-N=120V; L2-L3=208V, L2-N=120V; L3-L1=208V, L3-N=120V |
| 208/120 | 3 | 4 Position Voltage Selector Switch option - 208/120V 3-PHASE | Without convenience outlet buck transformer: GFCI outlets 120V, twist-lock outlets 120/208V | |
| 208/120 | 3 | Dedicated 12 lead generator - LOW WYE | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | Wiring block diagram - dedicated 12 lead generators option |
| 240/120 | 1 | 3 Position Voltage Selector Switch - 240/120V 1-PHASE | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | L1-L3=240V; L1-N=120V; L3-N=120V; L2-N = ------- |
| 240/120 | 1 | 4 Position Voltage Selector Switch option - 240/120V 1-PHASE | GFCI outlets 120V; twist-lock outlets 120/240V | |
| 240/120 | 1 | Dedicated 12 lead generator - LOW ZIG ZAG | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | Wiring block diagram - dedicated 12 lead generators option |
| 240/120 | 3 | 4 Position Voltage Selector Switch option - 240/120V 3-PHASE (DELTA) | GFCI outlets 120V; TWIST-LOCK OUTLETS SHOULD NOT BE USED | |
| 240/120 | 3 | Dedicated 12 lead generator - HIGH DELTA | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | Wiring block diagram - dedicated 12 lead generators option |
| 480/240 | 1 | Dedicated 12 lead generator - HIGH ZIG ZAG | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | Wiring block diagram - dedicated 12 lead generators option |
| 480/277 | 3 | 3 Position Voltage Selector Switch - 480/277V 3-PHASE | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | L1-L2=480V, L1-N=277V; L2-L3=480V, L2-N=277V; L3-L1=480V, L3-N=277V |
| 480/277 | 3 | 4 Position Voltage Selector Switch option - 480/277V 3-PHASE | Without convenience outlet buck transformer: GFCI outlets 139V, twist-lock outlets 240/139V | |
| 480/277 | 3 | Dedicated 12 lead generator - HIGH WYE | T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12 | Wiring block diagram - dedicated 12 lead generators option |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
| Part # | Description | Category |
|---|---|---|
| 34550 | Decal, 600V Circuit Breakers (MMG45FHKCAN6 only) | circuit_breakers_600v_decal |
| 21259 | Decal, Battery Charger (Optional) | other_service |
| 26387 | Decal Set, Rear Hood Latch | other_service |
| 28964 | Decal, Engine Block Heater (Optional) | other_service |
| 31024 | Decal, Fan Clutch (Optional) | other_service |
| 80D26Rx1 | Engine Oil | other_service |
| MMG45K | Generator Make: _______________________________________ Generator Model Number:________________________________ Generator Serial Number: ________________________________ | other_service |
| 34424 | Decal Set, Voltage Selector Switch (x2) | voltage_selector_switch_decal_set |
Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.
The Kubota V3600-T-E3BG engine has an oil capacity of 13.2 liters.
The Kubota V3600-T-E3BG has a displacement of 3.6 liters.
The Kubota V3600-T-E3BG powers 3 generator set(s), including Generac MMG45FHK, Magnum MMG45FHKCAN6, Magnum MMG45K.
A commonly reported issue on generators using the Kubota V3600-T-E3BG is: Overspeed or Underspeed Shut down. Fix: Disconnect all loads and restart the generator. Read the frequency (Hz) on the LCD display. With no loads on the generator, the frequency should read 60.0 Hz. If the frequency is above or below 60.0 Hz, the engine speed will have to be adjusted. See the engine manual for throttle adjustments on mechanically governed units and see the electronic governor manual for electronically controlled units..