Home›Repair guides›Generac›Reconfiguring the Fuel System (V-twin)

Generac — Reconfiguring the Fuel System (V-twin)

Adjustments

From a Generac owner's manual covering: GH-410, GT-530, GT-990, GT-999. Check it applies to your exact model before use.

Applies to: Generac GH-410, Generac GH-410 engine, Generac GT-530 engine, Generac GT-990 engine, Generac GT-999 engine

Before you start

  • Gaseous fuels are highly explosive. No leakage permitted.

Procedure

  1. Open roof.
  2. For 10kW: loosen clamp, slide back air inlet hose.
  3. Slide fuel selector on carburetor out towards back of enclosure.
  4. Return inlet hose and tighten clamp securely.
  5. For 12-20kW: remove air cleaner cover.
  6. Slide selector lever out towards back of enclosure.
  7. Return air cleaner cover and tighten two thumb screws.
  8. Close roof; reverse to convert back.

Specs & values

  • Fuel pressure 10 to 12 inches water column (0.36 to 0.43 psi) MUST BE SUPPLIED for LP

Full service-parts list: Generac GH-410 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.