HomeGeneracGenerac GH-410

Generac GH-410 Generator Set

The Generac GH-410 is a 8 kW standby generator set. It is available at 240 V, single-phase, 60 Hz and rated 33.3 A. Starting uses 540 group-26 batteries at 12 V.

8 kW
Standby
1
Document types

How to read your Generac serial & model number →

Service parts for the GH-410

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Frequency60.0 Hz
Standby power8 kW
Voltage options240 V
Phase1
Rated current[33.3, 45.8, 66.6, 83.3, 91.7] A
Circuit breaker[35, 50, 65, 90, 100] A
Battery group26R
Battery voltage12 V
Battery quantity540

Maintenance & consumables

ItemSpecCapacityPart #Interval
Air filterAir Filter0E9371A Amazon eBay $19.99
Oil filterOil Filter070185E Amazon $35.19 eBay $30.00 FridayParts $45.99

Service intervals

11
ItemActionHoursMonthsNotes
Oil levelCheck24 hrMonthly or 24 hours of continuous operation
Air cleanerInspect200 hr24 mo2Y or 200 hours
Air cleanerReplace200 hr24 mo2Y or 200 hours
Complete tune-upOther200 hr24 mo2Y or 200 hours; to be completed by a dealer
OilChange200 hr24 mo2Y or 200 hours; change after first 8 hours
Oil filterChange200 hr24 mo2Y or 200 hours; change after first 8 hours
Spark plug(s)Inspect200 hr24 mo2Y or 200 hours
Spark plug(s)Replace200 hr24 mo2Y or 200 hours
Battery charge stateCheck6 moEvery 6 months
Battery electrolyte levelCheck6 moEvery 6 months
Valve clearanceCheck6 moFirst service — After first 6 months of operation

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

31
TypeItemValueUnitCondition
GapSpark plug gap0.030inch8, 10 & 20kW
GapSpark plug gap0.040inch12, 14, 16 & 17kW
GapSpark plug gap0.76mm8, 10 & 20kW
GapSpark plug gap1.02mm12, 14, 16 & 17kW
OtherCompression Ratio GH-4108.6:1
OtherCompression Ratio GT-5309.5:1
OtherCompression Ratio GT-9909.5:1
OtherCompression Ratio GT-9999.5:1
OtherRated Horsepower @ 3,600 rpm GH-41014.8HP
OtherRated Horsepower @ 3,600 rpm GT-53018HP
OtherRated Horsepower @ 3,600 rpm GT-99032HP
OtherRated Horsepower @ 3,600 rpm GT-99936HP
PressureFuel pressure LP10 to 12inches water columnrequired
PressureFuel pressure natural gas5 to 7inches water columnrequired
SpeedFrequency60-62Hertzno-load
SpeedOperating RPM3600RPM
TorqueGovernor clamp bolt70inch-pounds8kW single cylinder
TorqueGovernor lever clamp bolt8N-m8kW
TorqueRocker arm jam nut174in/lbs
TorqueTransfer switch 200A conductor tightening torque275in-lbs200A switch
TorqueUtility service disconnect breaker line torque375in-lbs200A
TorqueUtility service disconnect breaker load torque275in-lbs200A
Valve clearanceValve clearance0.002 - 0.004inchcold engine
Valve clearanceValve clearance0.05 - 0.1mmcold engine
VoltageBattery charger output12.8 to 13.8VDCbattery disconnected
VoltageE1-E2 no-load240-246VACno-load
VoltageE1-Neutral no-load120-123VACno-load
VoltageE2-Neutral no-load120-123VACno-load
VoltageN1-N2 nominal240VACutility
VoltageN1-Neutral nominal120VACutility
VoltageN2-Neutral nominal120VACutility

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oil10W-30API Service Class SJ, SL or betterBetween 40° F and -10° F
Engine oilSAE 30API Service Class SJ, SL or betterAbove 32° F
Engine oilSynthetic 5W-30API Service Class SJ, SL or better10° F and below
FuelLiquid Propane (LP) VaporBtu content at least 2,520 Btus per cubic foot; pressure 10-12 inches water column (0.36-0.43 psi)Use vapor withdrawal system only
FuelNatural GasBtu content at least 1,000 Btus per cubic foot; pressure 5-7 inches water column (0.18-0.25 psi)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting Valve Clearance adjustment

⚠ Hold rocker arm jam nut in place as pivot ball stud is turned.

Tools: 10mm allen wrench, feeler gauge, socket wrench

  1. Engine should be cool before checking.
  2. Remove spark plug wires and position away from plugs.
  3. Remove spark plugs.
  4. Position piston at Top Dead Center (TDC) of compression stroke.
  5. Remove four screws attaching valve cover.
  6. Loosen rocker jam nut.
  7. Turn pivot ball stud with 10mm allen wrench while checking clearance.
  8. Tighten jam nut to 174 in/lbs torque and recheck clearance.
Reconfiguring the Fuel System (8kW) adjustment

⚠ Gaseous fuels are highly explosive. No leakage permitted.

Tools: plastic T-handle fuel selector

  1. Turn off main gas supply.
  2. Open roof and remove door.
  3. Remove battery if installed.
  4. Insert T-handle pin into selector knob hole.
  5. Pull out to overcome spring pressure, twist clockwise 90 degrees.
  6. Allow selector to return once aligned with LP position.
  7. Save tool with Owner's Manual.
  8. Install battery, door, close roof; reverse to convert back.
Reconfiguring the Fuel System (V-twin) adjustment

⚠ Gaseous fuels are highly explosive. No leakage permitted.

  1. Open roof.
  2. For 10kW: loosen clamp, slide back air inlet hose.
  3. Slide fuel selector on carburetor out towards back of enclosure.
  4. Return inlet hose and tighten clamp securely.
  5. For 12-20kW: remove air cleaner cover.
  6. Slide selector lever out towards back of enclosure.
  7. Return air cleaner cover and tighten two thumb screws.
  8. Close roof; reverse to convert back.
Battery Installation installation

⚠ Damage will result if battery connections are made in reverse.

⚠ Do not dispose of battery in fire.

  1. Set AUTO/OFF/MANUAL switch to OFF.
  2. Turn off utility power to transfer switch.
  3. Remove 7.5A fuse from generator control panel.
  4. Connect red battery cable to positive (POS or +) post.
  5. Connect black battery cable to negative (NEG or -) post.
Changing the Engine Air Cleaner (10kW) maintenance
  1. Lift roof and remove door.
  2. Turn worm gear clamp screw counterclockwise to loosen.
  3. Pull old filter off divider panel hub.
  4. Wipe away dust or debris from panel hub.
  5. Install new air cleaner onto hub.
  6. Turn worm gear clamp screw clockwise to tighten.
  7. Replace door and roof.
Changing the Engine Air Cleaner (12,14,16,17,20kW) maintenance
  1. Lift roof and remove door.
  2. Turn two screws counterclockwise to loosen.
  3. Remove cover and air filter.
  4. Wipe away dust or debris from air box.
  5. Install new air cleaner into air box.
  6. Install cover and turn two screws clockwise to tighten.
Changing the Engine Air Cleaner (8kW) maintenance
  1. Lift roof and remove door.
  2. Push back latch of yellow air filter access door to swing open.
  3. Pull out old air filter and discard.
  4. Install new filter, open end first into air box.
  5. Swing yellow door shut and snap to close.
  6. Replace door and close roof securely.
Changing the Engine Oil maintenance

⚠ DO NOT OVER FILL.

⚠ Never operate engine with oil level below Add mark.

Tools: container

  1. Run engine until warm, then set AUTO/OFF/MANUAL switch to OFF.
  2. Pull oil drain hose free of retaining clip, remove cap, drain oil.
  3. Replace cap and retain hose in clip.
  4. Remove old oil filter by turning counterclockwise.
  5. Apply clean oil to new filter gasket.
  6. Screw new filter on by hand until gasket contacts adapter.
  7. Tighten additional 3/4 to one turn.
  8. Refill with recommended oil, run one minute, check for leaks.
Out of Service Procedure maintenance

⚠ Never store battery on concrete or earthen floor.

  1. Start engine and let warm up.
  2. Close fuel shutoff valve and allow unit to shut down.
  3. Switch to OFF position.
  4. Set main circuit breaker to OFF.
  5. Remove 7.5A fuse and disconnect battery cables.
  6. Drain oil completely while warm; refill crankcase with oil.
  7. Attach tag indicating oil viscosity and classification.
  8. Remove spark plug(s), spray fogging agent, reinstall and tighten.
Return to Service maintenance

⚠ DO NOT USE TAP WATER IN THE BATTERY.

  1. Verify utility power is off and AUTO/OFF/MANUAL switch is OFF.
  2. Check tag for oil viscosity and classification; refill if necessary.
  3. Check battery state; fill cells with distilled water and recharge to 100%.
  4. Clean and wipe entire generator.
  5. Ensure 7.5A fuse is removed; reconnect battery observing polarity.
  6. Open fuel shutoff valve.
  7. Insert 7.5A fuse and start unit in MANUAL; allow warm up.
  8. Stop unit, turn on utility power, set switch to AUTO.
Spark Plug Maintenance maintenance

⚠ Do not blast spark plug(s) to clean.

Tools: wire feeler gauge, wire brush

  1. Clean area around base of spark plug(s).
  2. Remove spark plug(s) and check condition.
  3. Replace if worn or reuse questionable.
  4. Clean by scraping or washing with wire brush and solvent.
  5. Check gap with wire feeler gauge.
  6. Adjust gap by bending ground electrode.
ATS Manual Operation operation

⚠ Do NOT manually transfer under load.

⚠ Do not use excessive force when operating manually.

Tools: manual handle

  1. Turn generator AUTO/OFF/MANUAL switch to OFF.
  2. Turn OFF UTILITY SERVICE DISCONNECT circuit breaker.
  3. Attach manual handle to moveable contact carrier arm.
  4. Move handle UP for UTILITY (NORMAL) position.
  5. Move handle DOWN for GENERATOR (STANDBY) position.
  6. Remove handle and return to storage bracket when finished.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
Control system interconnectionsN1, N2, 0, 15B, 23Can be run in same conduit as AC power if length < 35 feet and all wiring rated 600V
1201Battery charger AC input to generator backed-up 120VAC circuit120VAC hot, neutralConnect via wire nuts
120/2401GENERATOR (STANDBY) source power cables to ATS GENERATOR supply terminalsE1, E2200A models
120/2401Non-essential customer LOAD leads to LSS switch terminalsE1, E2Load shed switch
120/2401UTILITY (NORMAL) power source cables to top of UTILITY SERVICE DISCONNECT circuit breakerN1, N2200A models

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Generac GH-410?

The Generac GH-410 is rated 8 kW standby.

What oil filter fits the Generac GH-410?

The Generac GH-410 uses oil filter part number 070185E.

What air filter does the Generac GH-410 use?

The Generac GH-410 uses air filter part number 0E9371A.

Parts

10
Part #DescriptionQtySystem
070185EOil Filter1Oil filter Amazon $35.19 eBay $30.00 FridayParts $45.99
0E7585ASpark Plug1Spark plug Amazon $16.99 eBay $31.65
0E9368Spark Plug (RL87YC or equivalent)1Spark plug Amazon $29.84 eBay $4.99
0E9371AAir Filter1Air filter Amazon eBay $19.99
0G0767ASpark Plug (RC12YC or equivalent)2Spark plug Amazon $17.29 eBay $18.00
0G0767BSpark Plug1Spark plug Amazon eBay $2.17
0J8478Air Filter1Air filter Amazon $28.99 eBay $20.00 KuduParts $15.00
073590AFUSE 5A X BUSS2Service part / kit Amazon eBay $45.99
0D7178TControl panel fuse1Service part / kit Amazon $6.99 eBay $26.44
0H3421S26R Exide Battery1Service part / kit Amazon eBay $283.32

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Owner's manual — 0E7300 (Generac)Owner's manual — ASPDS-Y-1SG (Generac)Owner's manual — Manual (Generac)
Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter 0E9371A$19.99
Oil filter 070185E$30.00
2 priced items$49.99