Home›Repair guides›Generac›Adjusting Valve Clearance

Generac G0072100 — Adjusting Valve Clearance

Adjustments · engine valvetrain

For the Generac G0072100, from the Generac owner's manual.

Applies to: Generac G0072100, Generac G-Force 400 Series engine, Generac G-Force 800 Series engine, Generac G-Force 1000 Series engine

Before you start

  • Risk of Burn. Allow the engine to cool before performing the following procedure.

Procedure

  1. Remove spark plug wire(s) and position away from spark plug(s).
  2. Remove spark plug(s).
  3. Remove the four screws attaching valve cover. Remove and discard gasket.
  4. Verify piston is at TDC of its compression stroke (both valves closed).
  5. Loosen rocker jam nut using a 10 mm wrench (10 kW units) or 13 mm wrench (20-24 kW units).
  6. Turn pivot ball stud using a 14 mm wrench (10 kW) or 10 mm hex key (20-24 kW) while checking clearance with a feeler gauge.
  7. Hold pivot ball stud and tighten rocker arm jam nut.
  8. Inspect valve clearance to verify it did not change.
  9. Install new valve cover gasket and valve cover; tighten fasteners in a cross pattern.
  10. Install spark plug(s) and tighten to 18 ft-lbs (25 Nm); attach spark plug wires.
  11. Repeat process for other cylinder if equipped.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

Full service-parts list: Generac G0072100 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.