Before you start
- Electrocution. Lethal voltage may be present at CTs.
Procedure
- Connect load bank to output.
- Place amp meter over circuit.
- Start generator and warm up.
- Apply rated load.
- Select Current Calibration menu.
- Adjust display to match amp meter.
- Save calibration.
- Repeat for CT2.
Tools required
- clamp-on ammeter Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- CT output approx 0-1.5 VAC based on load