Home›Repair guides›Cummins/Onan›Resetting the Emergency Stop

Cummins/Onan 2100 Series — Resetting the Emergency Stop

Operation · Emergency Stop button

For the Cummins/Onan 2100 Series, from the Cummins/Onan service manual.

Applies to: Cummins/Onan DFAB, Cummins/Onan DFAC, Cummins/Onan DFBF, Cummins/Onan DFCB, Cummins/Onan DFCC, Cummins/Onan DFCE, Cummins/Onan DFGB, Cummins/Onan DFGE, Cummins/Onan DFLB, Cummins/Onan DFLC, Cummins/Onan DFLE

Procedure

  1. Pull the button and allow it to pop out.
  2. Turn the O/Manual/Auto switch to O (Off).
  3. Press the front panel Fault Acknowledge/Reset button.
  4. Select Manual or Auto, as required.

Specs & values

  • Emergency Stop shutdown can be reset only at the PCC front panel.

Full service-parts list: Cummins/Onan DFBF →, Cummins/Onan DFCC →, Cummins/Onan DFCE →, Cummins/Onan DFGB →, Cummins/Onan DFGE →, Cummins/Onan DFLB →, Cummins/Onan DFLC →, Cummins/Onan DFLE →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.