Service parts for the QSX15
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredOil system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 500 kW |
| Standby kVA | 625 |
| Prime power | 455 kW |
| Emissions | Tier 2 |
| Controller | PowerCommand |
| Oil capacity | 91.0 L |
| Alternator | 35 amps |
| Voltage options | 277 V, 480 V, 255 V, 440 V, 220 V, 380 V, 127 V |
| Phase | 3 |
| Battery voltage | 24 V |
| Battery quantity | 1 |
| Coolant capacity | 42.0 L |
| Max ambient | 55 °C |
| Dimensions (L×W×H) | 2269×1332×1669 mm |
| Dry weight | 1658 kg |
| Sound level | 85.0 dBA |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | L028-2 | 50 hr | eBay | ||
| Fuel filter | — | 6000 hr | |||
| Oil filter | 3375049 | 24000 hr | Amazon eBay | ||
| Battery | 2 x 4D, started unit | — | 1250 hr | ||
| Belt | — | 3000 hr | |||
| Coolant | -35 | 58.0 L | — | 1250 hr | |
| Coolant filter | — | 3000 hr | |||
| Oil | 91.0 L | — | 24000 hr | ||
| Spark plug | — | 3000 hr |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service intervals
40| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Air cleaner | Check | 8 hr | X1; replace as necessary; refer to QSX15 engine manual | |
| All hardware (fittings, clamps, fasteners, etc.) | Check | 8 hr | Daily or After 8 Hrs | |
| Anti-freeze and DCA concentration | Check | 8 hr | X1; refer to QSX15 engine manual | |
| Battery charging system | Check | 8 hr | Daily or After 8 Hrs | |
| Coolant heater(s) | Check | 8 hr | Daily or After 8 Hrs | |
| Coolant level | Check | 8 hr | Daily or After 8 Hrs | |
| Drive belt | Check | 8 hr | X1; refer to Cummins QSX15 Series Engine Operation and Maintenance Manual for interval/procedure | |
| Engine oil level | Check | 8 hr | Daily or After 8 Hrs | |
| Fuel filter(s) | Drain | 8 hr | X1; refer to QSX15 engine manual | |
| General set inspection | Inspect | 8 hr | Daily or After 8 Hrs (X1); also Monthly/100 Hrs (X2). Check for oil, fuel, coolant, and exhaust system leaks; check exhaust audibly/visually with set running. | |
| Battery electrolyte level | Check | 100 hr | Monthly or After 100 Hrs | |
| Generator air outlet | Check | 100 hr | Monthly or After 100 Hrs | |
| Radiator hoses | Check | 100 hr | Monthly or After 100 Hrs; check for wear and cracks | |
| Oil and filter change (Generator Drive, 1500 rpm, 45 liter sump) | Change | 125 hr | 12 mo | fixed hour method, standby applications |
| Crankcase breather | Clean | 250 hr | 6 mo | X1; 6 Months or After 250 Hrs |
| Engine oil and filter | Replace | 250 hr | 6 mo | X1; 6 Months or After 250 Hrs; refer to QSX15 engine manual |
| Lubricating Oil and Filters | Change | 250 hr | 6 mo | |
| Oil and filter change (Generator Drive, 1800 rpm, 95 liter sump) | Change | 250 hr | 12 mo | fixed hour method, standby applications |
| Supplemental Coolant Additive (SCA) and Antifreeze Concentration | Check | 250 hr | 6 mo | |
| Water coolant filter | Replace | 250 hr | 6 mo | X1; 6 Months or After 250 Hrs |
| coolant leaks and coolant SCA concentration level | Check | 625 hr | 6 mo | Operate the engine and check |
| lubricating oil | Change | 625 hr | 6 mo | Change/Replace |
| lubricating oil filter | Replace | 625 hr | 6 mo | Change/Replace |
| Air Leaks, Air Intake and Exhaust Systems | Check | 1500 hr | 12 mo | |
| Cooling Fan Belt Tensioner | Check | 1500 hr | 12 mo | |
| Fuel Filter (Spin-On Type) | Replace | 1500 hr | 12 mo | |
| air cleaner restriction | Check | 1500 hr | 12 mo | |
| air compressor element | Replace | 1500 hr | 12 mo | |
| automatic belt tensioner | Inspect | 1500 hr | 12 mo | |
| coolant filter | Replace | 1500 hr | 12 mo | Change/Replace |
| engine wiring harness | Check | 1500 hr | 12 mo | |
| intake air and exhaust systems | Check | 1500 hr | 12 mo | Operate engine and check |
| crankcase breather tube | Clean | 3000 hr | 24 mo | |
| engine | Clean | 3000 hr | 24 mo | Steam-clean engine |
| engine hoses | Check | 6000 hr | 24 mo | Check all hose connections for leaks or deterioration |
| engine mounting bolts | Check | 6000 hr | 24 mo | |
| shutters and fan | Check | 3000 hr | 24 mo | |
| valves, injectors, and engine brakes | Adjust | 3000 hr | 24 mo | It is not necessary to adjust every 2 years per note 5 |
| vibration dampers | Check | 3000 hr | 24 mo | |
| Cold Weather Starting Aids | Check | 6000 hr | 24 mo |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
60| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Exhaust pipe clearance from combustible wall or partition | 12 | inches (305 mm) | minimum |
| Clearance | Exhaust pipe clearance to combustible wall or partition | 305 | mm | |
| Clearance | Fuel line clearance from electrical wiring | 1/2 | inch (12.7 mm) | minimum |
| Clearance | Fuel line clearance from hot exhaust parts | 2 | inch (51 mm) | minimum |
| Clearance | Fuel lines - minimum clearance from electrical wiring | 12.7 | mm | |
| Clearance | Fuel lines - minimum clearance from hot exhaust parts | 51 | mm | |
| Clearance | MPU installation gap adjustment | back out 1/4 turn after touching gear tooth | turn | |
| Clearance | Minimum clearance of fuel lines from electrical wiring | 12.7 | mm (1/2 inch) | |
| Clearance | Minimum clearance of fuel lines from hot exhaust parts | 51 | mm (2 inch) | |
| Clearance | Service/maintenance access clearance around generator set | 1 | meter | |
| Clearance | Vibration isolator base elevation difference | 0.25 | inch (6 mm) | shimmed or grouted within this of each other |
| Clearance | Vibration isolator nominal clearance (leveling bolt) | 0.25 | inch (6 mm) | minimum, or greater |
| Gap | Maximum air cleaner restriction | 6.2 (25.0) | kPa (in H2O) | |
| Other | Air starting motor minimum air pressure | 480 | kPa [70 PSI] | |
| Other | Battery specific gravity (fully charged) | 1.26 | specific gravity | at 80 F (27 C) |
| Other | Battery specific gravity state of charge 100% | 1.26 to 1.28 | specific gravity at 27°C [80°F] | |
| Other | CAN datalink main trunk maximum length | 40 | meters | no more than 30 devices |
| Other | CAN datalink stub maximum length | 1 | meter | stub from main trunk to each module |
| Other | CAN datalink transmission speed | 250 | KBaud | |
| Other | Compression ratio | 17.0:1 | ||
| Other | Drive belt tension new belt | 1110 | N [250 lbf] | 10 rib |
| Other | Drive belt tension new belt | 1330 | N [300 lbf] | 12 rib and 12 rib K section |
| Other | Drive belt tension new belt | 620 | N [140 lbf] | SAE belt sizes 0.380 in, 0.440 in, 1/2 in, 11/16 in, 3/4 in, 7/8 in, 4 rib, 5 rib |
| Other | Drive belt tension new belt | 710 | N [160 lbf] | 6 rib |
| Other | Drive belt tension new belt | 890 | N [200 lbf] | 8 rib |
| Other | Engine brake adjustment | 7.0 | mm [0.276 in] | cold (stabilized coolant temperature at 60°C [140°F] or below) |
| Other | Exhaust flow at rated load | 2900 | cfm (1370 L/s) | 1500 RPM |
| Other | Exhaust flow at rated load | 3200 | cfm (1510 L/s) | 1800 RPM |
| Other | Exhaust outlet size | 4 | in. NPD | |
| Other | Frequency regulation | Isochronous | ||
| Other | Low oil pressure adequate within | 15 | seconds | after starting |
| Other | Mounting bolt size securing bedframe to base | 16 | mm | |
| Other | Mounting bolts | 5/8 inch or 16 mm | inch / mm | anchored mounting bolts |
| Other | Over current warning threshold | 110 | % of rated | |
| Other | Short circuit shutdown threshold | 175 | % of rated current | |
| Other | Starting motor engagement limit | 30 | seconds | do not engage starting motor longer; wait 2 minutes between attempts |
| Other | Voltage regulation, no load to full load | ± 0.5 | % | |
| Pressure | BMEP at rated load (standby) | 353.0 | psi (2433.9 kPa) | standby rating |
| Pressure | BMEP at set rated load | 2433.9 (353.0) | kPa (psi) | standby rating |
| Pressure | Fuel transfer pump maximum inlet restriction capability | 16 | inch Hg | approximately equivalent to 20 feet of diesel |
| Pressure | Max allowable exhaust back pressure | 76 | mmHg (3 in.) | |
| Pressure | Max fuel inlet restriction | 5 | in. Hg (127 mmHg) | |
| Pressure | Max fuel return restriction | 6.5 | in. Hg (165 mmHg) | |
| Pressure | Max. fuel inlet pressure | 10 | PSI (69 kPa) | |
| Pressure | Max. fuel inlet restriction | 5 | in. Hg. (16.9 kPa) | |
| Pressure | Max. fuel return restriction | 3.05 | in. Hg. (10.3 kPa) | |
| Pressure | Max. static restriction (cooling air) | 0.5 | in. H2O (124.5 Pa) | standby and prime |
| Pressure | Maximum air cleaner restriction | 25.0 | in. H2O (6.2 kPa) | |
| Pressure | Maximum allowable exhaust back pressure | 27 in (686 mm) H2O / 6.8 kPa / 2.0 in (51 mm) Hg | in H2O / kPa / in Hg | |
| Pressure | Maximum allowable exhaust back pressure created by piping and silencer | 51 mm Hg [2 in Hg] / 682 mm H2O [27 in H2O] | mm Hg / mm H2O | power generation |
| Pressure | Maximum allowable exhaust back pressure created by piping and silencer | 76 mm Hg [3 in Hg] / 1016 mm H2O [40 in H2O] | mm Hg / mm H2O | industrial |
| Pressure | Maximum allowable fuel return line restriction | 229 | mm Hg [9.0 in Hg] | |
| Pressure | Maximum allowable pressure drop across charge air cooler | 14 kPa [2 psi] / 102 mm Hg [4 in Hg] | kPa / mm Hg | industrial |
| Pressure | Maximum allowable pressure drop from turbo outlet to intake manifold | 14 kPa [2 psi] / 102 mm Hg [4 in Hg] | kPa / mm Hg | power generation |
| Pressure | Maximum allowable restriction to pump with clean filter | 203 | mm Hg [8 in Hg] | |
| Pressure | Maximum allowable restriction to pump with dirty filter | 305 | mm Hg [12 in Hg] | |
| Pressure | Maximum back pressure | 10.2 (41.0) | kPa (in H2O) | |
| Pressure | Maximum coolant pressure | 227 | kPa [33 psi] | exclusive of pressure cap - closed thermostat at maximum no-load governed speed |
| Pressure | Maximum exhaust back pressure | 41.0 | in. H2O (10.2 kPa) | |
| Pressure | Maximum fuel inlet restriction | 5.0 | in. Hg (127.0 mm Hg) | at rated load |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | Fully formulated antifreeze/coolant | TMC RP329 (ethylene glycol) or TMC RP330 (propylene glycol) | 24.0 L | 50/50 mixture with quality water; engine only coolant capacity 24 liters [25 qt]. Drain and flush after 6000 hours or 3 years. | |
| Coolant | 50/50 ethylene glycol antifreeze and water (0 to -32C); 60/40 ethylene glycol/water (-32 to -54C) | TMC RP329 (ethylene glycol) or RP330 (propylene glycol) | 54°C to 0°C | 50/50 mixture gives -36C [-34F] freezing point and 110C [228F] boiling point; do not use low-silicate antifreeze meeting ASTM D4985 for extended service intervals | |
| Engine oil | 15W-40 | CES 20,076 (or CES 20071; API CH-4 alternative) | Synthetic engine oils API category III recommended for ambient temperatures consistently below -25°C [-13°F]; 0W-30 oils where ambient never exceeds 0°C [32°F]; arctic operation use synthetic CF-4/SG or CG-4/SH 5W-30 below -23°C [-10°F]. | ||
| Engine oil | 15W-40 (recommended); 10W-30 or 5W-30 for temperate/cold; synthetic 0W-30 API category III below -25C | CES 20071 or CES 20076 (or API CH-4); API CG-4 at reduced drain interval | Do not use API CC/CD/CE/CF (obsoleted) | ||
| Fuel | ASTM No. 2 D diesel fuel; blends of No. 2 D and No. 1 D below 0°C [32°F] | Viscosity must be kept above 1.3 cSt at 100°C [212°F] to provide adequate fuel system lubrication. | |||
| Fuel | ASTM No. 2 diesel | Cummins engines normally use ASTM No. 2 diesel fuel; will operate on alternate diesel fuels within specifications in the Cummins engine Operation and Maintenance Manual. | |||
| Fuel | Diesel | Viscosity 1.3-4.1 cSt at 40C (ASTM D445); Cetane 40 min above 0C, 45 min below 0C (ASTM D613); Sulfur not to exceed 0.05 mass% (0.0015% for aftertreatment engines) | Cloud point 6C [10F] below lowest ambient operating temperature | ||
| Fuel | Diesel fuel specified to ASTM No. 2 or BS EN 590:2000, Automotive fuels | ASTM No. 2 / BS EN 590:2000 | An electric solenoid valve in the supply line is recommended for all installations and required for indoor automatic or remote starting installations. Never use galvanized or copper fuel lines, fittings or fuel tanks. | ||
| Fuel | diesel | ASTM No. 2 or BS EN 590:2000 | Cummins engines normally use a diesel fuel specified to ASTM No. 2 or BS EN 590:2000; alternate diesel fuels within the specifications shown in the Generator Set Operator Manual (0908-0219) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
62| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 1123 | Shutdown After Battle Short | A shutdown fault occurred while Battle Short was enabled and Battle Short transitioned from enabled to disabled | Warning | Review the Fault History and perform corrective action |
| 1124 | Delayed Shutdown | Provides advanced warning of an impending generator set shutdown to loads which cannot handle sudden power loss | Warning | A shutdown fault is present; review fault history |
| 1131 | Battle Short Active | Battle short mode has been activated | Warning | Battle short function enabled |
| 1245 | CAN - Engine Shutdown | The PCC received a shutdown message from the ECM | Shutdown | Refer to the E-Controls service tool and the engine service manual |
| 1246 | CAN - Unknown Engine Fault | The PCC received an unknown message from the ECM | Warning | Refer to the E-Controls service tool and the engine service manual |
| 1247 | CAN - Engine Unannounced Fault | The PCC received an unknown message from the ECM | Warning | Refer to the E-Controls service tool and the engine service manual |
| 1248 | CAN - Engine Warning Fault | The PCC received an unknown message from the ECM | Warning | Refer to the E-Controls service tool and the engine service manual |
| 1311, 1312, 1317, 1318 | Customer Input | Nature of the fault is an optional customer selection | Disconnect signal lead from TB1 (CUST_IN1 TB1-4, CUST_IN2 TB1-5, CUST_IN3 TB1-6, CUST_IN4 TB1-7) and reset the control; if the message clears, external wiring has a short/open or the active input selection (closed/open) is not correct | |
| 1313-1316 | Network Fault 1 Through 4 | Indicates network input (#1-#4) is in an active state | Each fault function can be programmed (using the service tool) as Status, Warning, or Shutdown; change display name using up to 19 characters | |
| 1334 | Crit Scaler OR | An incorrect feature or calibration was entered into the control | Shutdown | Correct the feature/calibration entered into the control |
| 1335 | Non-Crit Scaler OR | An incorrect feature or calibration was entered into the control | Warning | Correct the feature/calibration entered into the control |
| 135 | Oil Pressure Sensor High | Engine oil pressure sensor is shorted high | Warning | Verify fault simulation not enabled (InPower); inspect sensor and engine harness connector pins; use oil pressure sensor simulator to check control response, replace sensor if it responds; check P7-13, 17, 21 for short (>200k ohms OK) and open (10 ohms or less OK) |
| 141 | Oil Pressure Sensor Low | Engine oil pressure sensor is shorted low | Warning | Verify fault simulation not enabled; inspect sensor/harness connector pins; use simulator to check control response; check P7-13, 17, 21 short/open |
| 1416 | Fail to Shutdown | A shutdown fault was bypassed while the PowerCommand controller was in Battle Short mode | Warning | Review the fault history record |
| 1417 | Power Down Failure | The control has failed to go to sleep | Warning | Possible base board fault |
| 143 | Pre-Low Oil Pressure | Engine oil pressure dropped below the low oil pressure warning threshold | Warning | Verify fault simulation not enabled; check oil level, lines and filters; use oil pressure sensor simulator; check +5 VDC at sensor (E1-A) and at P7-21; use simulator to P7-13 (OP OUT) and P7-17 (OP COMM); isolate to harness or base board |
| 1433 | Emergency Stop | Indicates a local Emergency Stop | Shutdown | Pull the Emergency stop button out; move the O/Manual/Auto switch to O; press the front panel Fault Acknowledge/Reset button; select Manual or Auto as required |
| 1434 | Remote Emergency Stop | The Remote Emergency Stop has been activated | Shutdown | Check for activated Remote Emergency stop button; check for faulty connection or faulty emergency stop switch |
| 1435 | Low Coolant Temperature | Initiates a warning when the engine jacket water coolant temperature falls below 70 degrees F (21 degrees C). Provided with illumination of the Warning LED to meet NFPA 110 requirements. | Warning | Verify fault simulation not enabled; reset threshold to lowest allowable; check engine coolant heater (connections, fuse, coolant level, heater element/thermostat: flush with cold water and check coil resistance 10-60 ohms); inspect sensor/harness; use resistive simulator; check P7-30 and P7-34 short circuits |
| 144 | Coolant Temperature Sensor High | Coolant temperature sensor signal is shorted high | Warning | Verify fault simulation not enabled; inspect sensor/harness pins; use resistive sensor simulator, replace sensor if control responds; check P7-30 (IH20) and P7-34 (IH20 COM) for short to ground and pin-to-pin (>200k ohms OK); compare sensor resistance between pins |
| 1442 | Weak Battery | Battery voltage sensed by the alternator control dropped below the Weak Battery Voltage threshold for the set time | Warning | Refer to Fault Code 441 |
| 1443 | Battery Failed | Dead battery - engine will not start | Shutdown | Refer to Fault Code 441 |
| 1444 | kW Overload | The Overload Warning Threshold was exceeded for the registered Overload Warning Set Time | Warning | Reset threshold to highest allowable; check load and load cables for short/overload; check CTs and CT connections; check continuity from P7 to CTs (P7-11/P7-12 CT1, P7-15/P7-16 CT2, P7-19/P7-20 CT3) |
| 1445 | Short Circuit | Alternator output current exceeded 175% of rated current | Shutdown | Inspect load and load cables for damage/short; verify CT connections to J12-1 through J12-6; ensure controller set for correct CT ratio |
| 1446 | High AC Voltage | One or more phase voltages exceeded the High AC Voltage Threshold percentage for the High AC Voltage Delay | Shutdown | Verify fault simulation not enabled; clear fault following large block load removal; reset threshold to highest allowable; follow Generator/Base Board Isolation Procedure in alternator service manual |
| 1447 | Low AC Voltage | One or more phase voltages decreased below the Low AC Voltage Threshold for the Low AC Voltage Delay | Shutdown | Verify fault simulation not enabled; reset Low AC Voltage Threshold; check for overload; inspect PT connections (L1 J22-1, L2 J22-2, L3 J22-3, LN J22-4) and PT ratio; check AVR power supply and fuses at J18-1/J18-2 (10 Amp); measure AVR Powerstage output at J17-1/J17-2; check PMG voltages/resistances; check rotating rectifier diodes |
| 1448 | Under Frequency | Frequency dropped below the Underfrequency Threshold for the Underfrequency Delay | Shutdown | Verify fault simulation not enabled; reset threshold to lowest allowable; check/correct overload; check fuel or air supply; repair loose connector (P8) |
| 1449 | Over Frequency | Frequency exceeded the Overfrequency Threshold for the Overfrequency Delay | Warning | Ensure Overfrequency Enable not enabled; configure Overfrequency Threshold; verify frequency to speed gain (120/number of poles); check crankshaft/camshaft speed sensor connections and clearance; check sensor supply (4.75-5.25 VDC pins 16/37) and signal (0.46-4.56 VDC pins 27/26); check harness resistance (5 ohms or less); check for air in fuel system |
| 145 | Coolant Temperature Sensor Low | Coolant temperature sensor signal is shorted low | Warning | Verify fault simulation not enabled; inspect sensor/harness pins; use resistive sensor simulator; check P7-30 and P7-34 for short circuits and compare resistance |
| 146 | Pre-High Coolant Temperature | Engine coolant temperature exceeded the warning threshold for pre-high/high coolant temperature | Warning | Verify fault simulation not enabled; isolate to engine or sensor circuitry, check sensor accuracy with thermocouple; use coolant temperature sensor simulator; check P7-30 and P7-34 for short circuits and compare resistance |
| 1461 | Loss of Field | Loss of field (electric) due to reverse kVAR | Shutdown | Investigate loss of field condition |
| 1466 | Modem Failure | The control cannot communicate with the modem | Warning | Check for an open short circuit to ground and loose connections to the modem |
| 1468 | Network Error | Momentary loss of communication from the LonWorks network | Warning | Refer to the LonWorks network publications for troubleshooting methods |
| 1469 | Speed/Hz Match | Measured speed and measured AC output frequency do not agree | Shutdown | Check the calibration file |
| 1471 | Over Current | Generator set output exceeded 110% of rated | Warning | Refer to Fault Code 1444 |
| 1472 | Over Current | Generator output current exceeded 110% of rated and a control time/current calculation initiated an overcurrent shutdown | Shutdown | Check the load and load lead connections (the fault may not reset for several minutes) |
| 151 | High Coolant Temperature | Engine coolant temperature exceeded the warning threshold for pre-high/high coolant temperature | Warning | Verify fault simulation not enabled; isolate to engine or sensor circuitry; check sensor accuracy with thermocouple; use coolant temperature sensor simulator; check P7-30 and P7-34 short circuits and compare resistance |
| 197 | Low Coolant Level | Engine coolant level dropped below the low coolant level warning threshold (optional) | Warning | Check and replenish coolant in radiator; if normal, isolate low coolant signal (GND); disconnect signal lead at sender and reset control, replace sender if message clears; check continuity from P7-32 to ground and replace harness if continuity exists |
| 2331 | Low AC Voltage (Battery Charger) | AC input voltage is more than 10% below nominal rated voltage | Warning | Check level of input voltage; charger will not operate with voltage 10% or more below nominal |
| 2335 | Excitation Fault | The control detected simultaneous loss of all phase sensing | Shutdown | Check parameters configuration and wiring |
| 2336 | Memory Error | Control memory error resulting in data corruption of critical operating parameters | Shutdown | Try reloading the calibration file |
| 234 | Overspeed | Engine speed signal indicates engine speed greater than the shutdown threshold | Shutdown | Cold engine: clear fault and restart; large block load removal: clear and restart; verify fault simulation not enabled; reset threshold via InPower; monitor engine RPM; check electronic governor actuator for binding |
| 2341 | High Control Temperature | Control temperature is above normal (158 F [70 C]) for longer than the control temperature set time | Warning | Check the generator set room air flow |
| 2342 | Too Long in Idle | Engine running at idle speed longer than the Maximum Idle Time parameter | Warning | Check Maximum Idle Time parameters; check coolant heater(s); avoid idling more than 20 minutes |
| 235 | Low Coolant Level | Engine coolant level dropped below the low coolant level shutdown threshold | Shutdown | Refer to fault code 197 |
| 2358 | High AC Voltage (Battery Charger) | AC input voltage is more than 10% above nominal rated voltage | Warning | Check level of input voltage; charger will not operate with voltage 10% or more above nominal |
| 27 | Low AC voltage shutdown | Voltage on any phase has dropped below a preset value; adjustable 50-95% of reference, delay 2-20 seconds; default 85% for 10 seconds | Shutdown | Genset shut down on low AC output voltage |
| 2967 | Governor Fault | Governor hardware drive circuitry contains a fault condition | Warning | Investigate governor hardware drive circuitry |
| 2968 | AVR Fault | AVR hardware contains a fault condition | Warning | Investigate AVR hardware |
| 2969 | LON Failure | No communications with the LonWorks board | Warning | Investigate LonWorks board communication |
| 2972 | Field Overload | Field AVR Duty Cycle operating at maximum output longer than the Max Field Time parameter | Shutdown | Check Max Field Time Delay parameter; check voltage sensing into base board for low voltage or open/short circuit; check alternator or application issue |
| 32 | Reverse power shutdown | Adjustment range 5-20% of standby kW rating, delay 1-15 seconds; default 10%, 3 seconds | Shutdown | Genset shut down on reverse power |
| 359 | Fail to Start (3.3L Electronic Governed Engine) | Engine failed to start after expiration of the last crank time | Shutdown | Check/restricted fuel supply: add fuel and prime, open shutoff valve, bleed air; check injection pump actuator and governor: check P7-24 (ACT+) and P7-28 (ACT-) continuity, measure actuator resistance (2.3 ohms OK), check CNTL B+ and GOV PWM signal, replace actuator if open/short/binding |
| 379 | Over Current (Battery Charger) | Charger output current is too high | Warning | Cycle through Setup menus to try to clear the fault; if the fault returns the charger control may have failed. Clear by disconnecting the charger harness plug, cycling completely through the setup menus, or recycling power |
| 415 | Low Oil Pressure | Engine oil pressure dropped below the low oil pressure shutdown threshold | Shutdown | Refer to fault code 143 |
| 427 | CAN Datalink Lost Message | Important data was lost between the Base Board and the ECM, or keyswitch to ECM was removed during genset operation | Warning | Reset control by pressing Fault Reset button with O/Manual/Auto switch in O (off); inspect Datalink harness between P10 and P41; check lead P10-1 to P41-N and P10-2 to P41-P (10 ohms or less = ok); measure terminating resistors (60 ohms = ok) |
| 441 | Low Battery Voltage | Low battery voltage has been detected | Warning | Clean/tighten battery connectors; replenish electrolyte and recharge; recharge/replace battery; verify battery voltage (12 or 24 VDC) matches calibration; adjust charge rate; replace engine DC alternator if normal charging voltage (12 to 14 or 24 to 26 VDC) not obtained; check harness P7-3/P7-7 and P7-4/P7-8 |
| 442 | High Battery Voltage | High battery voltage has been detected | Warning | Adjust charge rate per manufacturer; replace engine DC alternator if normal charging voltage not obtained; verify battery voltage (12 or 24 VDC) matches calibration |
| 59 | High AC voltage shutdown | Output voltage on any phase exceeds preset values; adjustable 105-125% of nominal, time delay 0.1-10 seconds; default 110% for 10 seconds | Shutdown | Genset shut down on high AC output voltage |
| 781 | CAN Datalink Lost Messages | Important data was lost between the Base board and the ECM, or keyswitch to ECM was removed during genset operation | Warning | Refer to fault code 427 |
| 81 o | Over frequency shutdown/warning | Generator set is operating at a potentially damaging frequency level; 2-10 Hz above nominal, 1-20 second delay; default 6 Hz, 20 seconds, disabled | Shutdown | Shutdown/warning on over frequency |
| 81 u | Under frequency shutdown | Generator set output frequency cannot be maintained; 2-10 Hz below reference, 5-20 second delay; default 6 Hz, 10 seconds | Shutdown | Genset shut down on under frequency |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Engine Brake Assembly - Adjust adjustment
⚠ To get maximum brake operating efficiency and to prevent engine damage, follow instructions in this section.
Tools: 3163530 Brake Feeler Gauge - 7.00 mm [0.276 in]
- Remove eight capscrews, isolator assemblies, rocker lever cover, and rocker lever cover gasket.
- Locate engine brake set marks: BRAKE SET 1-6, 2-5, 3-4.
- Rotate engine clockwise until set mark aligns with stamped mark on front gear cover.
- Verify both intake and exhaust valves on cylinder are closed and camshaft follower is on inner base circle.
- Press engine brake lever down to verify follower contacts camshaft.
- Loosen locknut on brake lever adjusting screw and back out one turn.
- Insert feeler gauge Part No. 3163530 between bottom of engine brake piston and top of exhaust valve pin.
- Tighten adjusting screw until drag on feeler gauge is felt.
- Hold adjusting screw and tighten locknut to 20 Nm [15 ft-lb]. Remove feeler gauge.
- Repeat on remaining cylinders.
- Install rocker lever cover gasket, cover, isolators, and capscrews. Tighten to 25 Nm [18 ft-lb].
Magnetic Speed Pickup Unit (MPU) Installation adjustment
⚠ Do not use fan blade to bar over the engine; that can damage blades and cause property damage and personal injury.
Tools: Ohmmeter
- Measure the resistance of the MPU; replace if not between 1,000 ohms and 1,050 ohms.
- With the MPU removed, bar the engine until a flywheel gear tooth lines up in the center of the mounting hole.
- Thread the sensor in gently by hand until it just touches the gear tooth.
- Back it out 1/4 turn and set the locknut.
- After adjustment, verify output voltage of the MPU is correct.
Overhead Set - Adjust adjustment
⚠ Do not use solvent to clean rocker cover gasket.
⚠ Batteries can emit explosive gases. Disconnect battery before service.
Tools: 3375044 Torque Wrench, Feeler gauge
- Disconnect battery.
- Locate valve set marks on outside of vibration damper: A adjusts cylinders 1 or 6, B adjusts cylinders 2 or 5, C adjusts cylinders 3 or 4.
- Rotate engine clockwise to align set mark with pointer. Check both valves are closed.
- Loosen injector adjusting screw locknut. Use dial-type torque wrench to tighten injector rocker lever adjusting screw.
- Back out adjusting screw one or two turns. Tighten injector adjusting screw to 8 Nm [70 in-lb].
- Hold injector lever adjusting screw and tighten locknut to 75 Nm [55 ft-lb].
- Set valves on same cylinder using feeler gauge: intake 0.36 mm [0.014 in], exhaust 0.69 mm [0.027 in].
- Tighten valve adjusting screw to 0.6 Nm [5 in-lb]. Hold screw and tighten locknut to 45 Nm [33 ft-lb].
- Repeat for all cylinders following firing order 1-5-3-6-2-4.
Engine Does Not Crank in Manual Mode - Diagnosis and Repair diagnostic
⚠ Accidental starting can cause severe personal injury or death; disconnect negative (-) battery cable with insulated wrench.
⚠ Set generator set to off mode before disconnecting/connecting harness connectors.
Tools: True RMS meter, Insulated wrench, Jumper leads
- Verify power to control: Control Alive indicator should be flashing on base board.
- Clean battery cable terminals and tighten connections using an insulated wrench.
- Remove F4 and check continuity; if open, replace with same type/amp rating (5 Amps).
- If F4 OK, remove connector P7 and check B+ at P7-1 to P7-4 and GND at P7-5 to P7-8.
- If B+/ground missing, isolate to harness and TB BAT terminal on engine block.
- If B+ and ground OK, base board may be defective; cycle power by reconnecting P7.
- Confirm calibration part number matches serial plate; re-enter calibration file if needed.
- With E-Stop not activated, remove P1 and check continuity between P1-1 (ESTOP-NC1) and P1-2 (ESTOP-NC2).
- With S12 in Manual, remove P1 and check continuity from P1-6 (MAN) to P1-9 (GND).
- Remove P3 and check continuity from P3-9 (MAN RUN/STOP) to P3-10 (GND); if none when pressing button, replace front membrane panel.
Testing SCA Concentration Level diagnostic
⚠ Do not remove pressure cap from a hot engine; wait until coolant is below 50C [120F].
Tools: CC2602 Coolant Test Kit
- Ensure coolant sample is between 10 and 54 C [50-130F].
- Compare test strip pads to color chart in daylight or cool white fluorescent lighting.
- Use one strip at a time; do not touch pads.
- If concentration is below 1.2 units per gallon, replace filter and precharge with liquid.
Testing the Float Switch Assembly diagnostic
Tools: Ohmmeter, Feeler gauge
- Remove the fuel pump control cover, disconnect the wiring jack, and unscrew the assembly from the top of the day tank.
- With an ohmmeter, test for electrical continuity (switch closed) between each pair of colored leads while holding the assembly vertical; replace if any switch is open (readings should be zero).
- Lift each float to 1/8 inch (3 mm) below the C-clip stop above it (use a feeler gauge); test for continuity; replace if any switch does not open (readings should be infinity).
- Use pipe thread sealant when replacing the assembly.
AC Electrical Connections installation
⚠ Accidental starting of the generator set can cause severe personal injury or death. Prevent accidental starting by disconnecting the negative (–) cable from the battery terminal.
⚠ Improper wiring can cause a fire or electrical hazard.
⚠ Backfeed to utility system can cause electrocution or property damage. Do not connect to any building electrical system except through an approved device.
- Place the control panel run switch in the OFF position.
- Turn off or remove AC power from the battery charger.
- Remove the negative (–) battery cable from the set starting battery.
- Install the transfer switch, select generator output voltage, connect load cables and connect standard/optional AC equipment.
Battery Connections installation
⚠ Ignition of explosive battery gases can cause severe personal injury or death. Always connect negative (–) battery cable last to prevent arcing.
⚠ Ventilate battery area before working on or near battery.
- Make sure that the PCC is in the OFF mode before connecting the battery cables.
- Connect the positive battery cable before connecting the negative battery cable to prevent arcing.
- Service the batteries as necessary.
- If an automatic transfer switch is installed without a built-in charge circuit, connect a separate battery charger.
Coolant Heater Installation installation
⚠ The coolant heater must not be operated while the cooling system is empty or damage to the heater will occur.
- Connect the heater to a source of power that will be on during the time the engine is not running.
- Ensure the supply voltage and circuit current is correct for the heater element rating.
Current Transformer (CT) Installation installation
- Ensure the CT dot is facing toward the generator reconnection terminal block (conventional current flowing into the dot).
- Route the load lead (U, V or W) through the appropriate CT per the Reconnection Diagram.
- Connect CT secondary wire marked 1 to pin 1 of the CT.
- Connect CT secondary wire marked 2/3 to pin 3 for low voltage generator sets.
Current Transformer (CT) Installation Requirements installation
- The CT has a dot on one side. This dot must face toward the generator (conventional current flowing into the dot).
- CT21 - U load leads (A phase); CT22 - V load leads (B phase); CT23 - W load leads (C phase).
- Route the appropriate load wires through each CT.
- CT secondaries have 3 pins: secondary wire marked 1 to pin 1; wire marked 2/3 to pin 2 for high voltage gensets or pin 3 for low voltage gensets.
DC Control Wiring Installation installation
⚠ Hazardous voltage! Ensure all power is off before performing control wire installation.
⚠ Always run control circuit wiring in separate metal conduit from AC power cables.
Tools: cable ties, flexible conduit
- Route the control wiring through the bottom of the control housing, keeping DC wiring away from high voltage AC wiring.
- Use cable ties to keep control wiring away from sharp edges and AC power cables within the control housing.
- Use 20 gauge stranded copper wire for digital connections less than 305 metres (1000 feet).
- Use 18 gauge stranded copper wire for digital connections 305 to 610 metres (1000 to 2000 feet).
- Determine the gauge of stranded copper wire for relay connections according to the devices attached.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| U, V, W, N terminals (U,V,W = L1,L2,L3; N = L0) | Stranded load wires bolted to generator reconnection terminal block or circuit breaker lugs | Generators can be configured to the nameplate voltages as shown on the Reconnection Diagram decal attached to the backside of the control box cover; many voltages require reconfiguration of the generator output leads. | ||
| 110/190 | 3 | 12 | Full load current at Standby rating: 1901 A | |
| 110/220 | 3 | 12 | Full load current at Standby rating: 1642 A | |
| 115/230 | 3 | 12 | Full load current at Standby rating: 1571 A | |
| 120/208 | 3 | 12 | Full load current at Standby rating: 1737 A | |
| 139/240 | 3 | 12 | Full load current at Standby rating: 1505 A | |
| 220/380 | 3 | 12 | Full load current at Standby rating: 951 A | |
| 230/400 | 3 | 12 | Full load current at Standby rating: 903 A | |
| 240/416 | 3 | 12 | Full load current at Standby rating: 868 A | |
| 255/440 | 3 | 12 | Full load current at Standby rating: 821 A | |
| 277/480 | 3 | Wye, 4 Wire | 12 | Full load current at Standby rating: 753 A |
| 347/600 | 3 | 12 | Full load current at Standby rating: 602 A |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
How many kW is the Cummins/Onan QSX15?
The Cummins/Onan QSX15 is rated 500 kW standby (625.0 kVA).
What engine is in the Cummins/Onan QSX15?
The Cummins/Onan QSX15 is powered by the Cummins/Onan 550 (625) engine.
What fuel does the Cummins/Onan QSX15 use?
The Cummins/Onan QSX15 runs on Diesel.
How much coolant does the Cummins/Onan QSX15 hold?
The Cummins/Onan QSX15 cooling system holds 42 liters (11.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
How much oil does the Cummins/Onan QSX15 take?
The Cummins/Onan QSX15 has an engine oil capacity of 91 liters (96.2 US quarts), per the manufacturer specification sheet.
What is the prime power rating of the Cummins/Onan QSX15?
The Cummins/Onan QSX15 is rated 455 kW prime (569 kVA), against 500 kW standby.
How loud is the Cummins/Onan QSX15?
The Cummins/Onan QSX15 is rated at 85.0 dBA, per the manufacturer specification sheet.
How much does the Cummins/Onan QSX15 weigh?
The Cummins/Onan QSX15 has a dry weight of 1658 kg (3655 lb).
What voltage does the Cummins/Onan QSX15 produce?
The Cummins/Onan QSX15 is offered in 277 V, 480 V, 255 V, 440 V, 220 V, 380 V, 3-phase.
What battery does the Cummins/Onan QSX15 use?
The Cummins/Onan QSX15 uses 1 battery, 24 V each, per the manufacturer specification sheet.
Which alternator is fitted to the Cummins/Onan QSX15?
The Cummins/Onan QSX15 uses a 35 amps alternator.
What oil filter fits the Cummins/Onan QSX15?
The Cummins/Onan QSX15 uses oil filter part number 3375049.
What air filter does the Cummins/Onan QSX15 use?
The Cummins/Onan QSX15 uses air filter part number L028-2.
Repair guides
58- Air Compressor Carbon Buildup - Maintenance Check
- Air Compressor Carbon Buildup - Maintenance Check
- Belt Tensioner, Automatic - Inspect for Reuse
- Belt Tensioner, Automatic - Inspect for Reuse
- Coolant Filter - Install
- Coolant Filter - Install
- Crankcase Breather Tube - Disassemble and Assemble
- Crankcase Breather Tube - Disassemble and Assemble
- Current Transformer (CT) Installation Requirements
- Current Transformer (CT) Installation Requirements
- Current Transformer (CT) Installation Requirements
- DC Control Wiring Installation
- Engine Brake Assembly - Adjust
- Engine Brake Assembly - Adjust
- Engine Does Not Crank in Manual Mode - Diagnosis and Repair
- Entering Password
- Entering Password
- Fan Hub, Belt Driven - Maintenance Check
- Fan Hub, Belt Driven - Maintenance Check
- Fuel Filter (Spin-On Type) - Install
Step-by-step procedures compiled from the Cummins/Onan service manual for this model.
Parts
20model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 0908-0101 | Lead Acid Battery | 1 | Battery | Amazon eBay |
| 0908-0203 | Operator manual | Operator manual | Amazon eBay | |
| 0908-0204 | Operator manual | Operator manual | Amazon eBay | |
| 0908-0230 | Generator Set Operator Manual | Operator manual | Amazon eBay | |
| 19802521 | ECM Dataplate | ECM / ECU | Amazon eBay | |
| 3331096 | Cummins, Part No. 3331096 | 1 | Fuel filter | Amazon eBay $74.95 |
| 3375044 | Torque Wrench | 1 | Belt | Amazon eBay |
| 3375049 | Oil Filter Wrench | 1 | Oil filter | Amazon eBay |
| 3376807 | Fuel filter | 1 | Fuel filter | Amazon eBay |
| 3406810 | Combination Full-Flow/Bypass Lubricating Oil Filter Cummins Part No. 3406810 | 1 | Oil filter | Amazon eBay KuduParts $34.00 FridayParts $62.22 |
| FS1007 | Fleetguard® Nelson®, Part No. FS1007 | 1 | Fuel filter | Amazon eBay KuduParts $51.00 |
| 0908-0107 | Radiator Information | 1 | Service part / kit | Amazon eBay |
| 0908-0110 | Health and Safety (Diesel Generator Sets) | 1 | Service part / kit | Amazon eBay NAPA $5.89 |
| 0908-0219 | Alarm Module (option) | Service part / kit | Amazon eBay | |
| 17200015 | Engine Shutdown | Service part / kit | Amazon eBay | |
| 17690172 | Engine Braking System | Service part / kit | Amazon eBay | |
| 17800006 | Engine Model | Service part / kit | Amazon eBay | |
| TB3-5 | Generator Set Control Panel Terminal Block | 1 | Service part / kit | Amazon eBay FridayParts $399.75 |
| TB3-6 | Generator Set Control Panel Terminal Block | 1 | Service part / kit | Amazon eBay FridayParts $65.10 |
| ol204vt | Torque Peak | Service part / kit | Amazon eBay |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 107.3 | 28.4 |
| Standby | 100% | 94.1 | 24.9 |
Available documents
This page was generated from the 20 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.