Home›Kohler›Kohler KD1750

Kohler KD1750 Generator Set

The Kohler KD1750 is a 1440 kW (1800 kVA) Diesel standby generator set powered by a Kohler KD45V20 engine. It is available at 220/380 V, 230/400 V, 240/415 V and 1905/3300 V, 3-phase and 50 Hz. It holds about 180 L (47.6 gal) of oil and 285 L (75.3 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 4 batteries rated 1110 CCA at 12 V. The set measures 5689×2152×2415 mm (224.0×84.7×95.1 in). An integrated tank holds 5863 L (1548.8 gal).

1440 kW
Standby
45.0 L
Displacement
180.0 L
Oil capacity
4
Document types

How to read your Kohler serial & model number →

Compare with other 1440–1445 kW Diesel generators →

Service parts for the KD1750

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Fuel system

2 required
330510016Fuel filter (primary)$33.15eBay
230510004Fuel filter (secondary)$40.00eBay

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power1440 kW
Standby kVA1800
Prime power1296 kW
ControllerAPM603, APM802
Oil capacity180.0 L
AlternatorKH04920TO4D, KH05641TO4D, KH05740TO4D, KH06400TO4D, KH06721TO4D, KH06810TO4D
Voltage options220/380 V, 230/400 V, 240/415 V, 1905/3300 V
Phase3
Power factor0.8
Battery cranking1110 CCA
Battery voltage12 V
Battery quantity4
Coolant capacity285.0 L
Engine jacket water143.0 L
Max ambient40 °C
Dimensions (L×W×H)5689×2152×2415 mm
Fuel tank5863.0 L

Engine

Kohler KD45V20
Oil capacity45.0 L
Coolant capacity45.0 L
Displacement45.0 L
AspirationTurbocharged
Rated speed1500 rpm

Maintenance & consumables

for the Kohler KD45V20
ItemSpecCapacityPart #Interval
Air filter10801001001 Amazon eBay NAPA $242.77
Fuel filterPrimary Engine Filter×1330510016 Amazon eBay $33.15 NAPA $127.04
Fuel filterSecondary2305100041000 hr Amazon eBay $40.00
Oil filter×4230510001250 hr Amazon eBay $40.80 NAPA $117.18
Battery4, 1110, AGM×4—
Beltbattery charging alternator—3000 hr
CoolantSI-OAT or hybrid technology with ethylene glycol143.0 l—6000 hr
OilFull Pressure180.0 L—250 hr

Service intervals

25
ItemActionHoursMonthsNotes
Fan bearing lubrication (KD2000-KD4000)Lubricate500 hr500 Hrs.
Fan belt(s)Check500 hr12 moYearly or 500 Hrs.; replace as necessary; follow engine manual
Fuel prefilter(s)Replace500 hr24 mo2 Years or 500 Hrs.; follow engine manual
Main fuel Filter(s)Replace1000 hr24 mo2 Years or 1000 Hrs.; follow engine manual
Water pump and alternator beltsCheck2000 hr24 mo2 Years or 2000 Hrs.; replace as necessary; follow engine manual
Air cleaner serviceReplace3000 hr24 mo2 Years or 3000 Hrs.; follow engine manual
DEF tank vent filterReplace3000 hr24 mo2 Years or 3000 Hrs.; follow engine manual
Coolant, replaceReplace6000 hr48 mo4 Years or 6000 Hrs.; follow engine manual
AC electrical system, safety and alarm operationTest6 mo6 Months; check
Battery charger operation, charge rateCheck1 moMonthly
Battery electrolyte levelCheck1 moMonthly; not necessary with AGM batteries
Battery recharge after engine startCheck1 moMonthly
Battery specific gravity, charge stateTest1 moMonthly; not necessary with AGM batteries
Circuit breakers, fusesInspect1 moMonthly; replace as necessary; do not break manufacturer's seals
Clean and tighten battery terminalsClean3 moQuarterly; check
Coolant temperatureTest6 mo6 Months; follow engine manual
Crankcase breather filter(s)Replace3 moQuarterly; follow engine manual
DEF fill neck filterInspect12 moYearly; check; replace as necessary
DEF suction module filterInspect12 moYearly; check; replace as necessary
Exhaust flexible connector(s)Inspect6 mo6 Months
On-Load TestTest12 moYearly; perform loaded operation 30-60 minutes
RTC Battery, APM802Replace36 moAPM802, 3 Years; service by authorized Rehlko service representative
Remove corrosion, clean and dry battery and rackClean1 moMonthly
Start Test (monthly exercise with Conscious Care™)Test1 moMonthly
Tighten DC electrical connectionsOther6 mo6 Months; tighten

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
Other10 in. weld flange bolt circle diameter B361.95mm (14.25 in.)
Other10 in. weld flange outside diameter C406.4mm (16.0 in.)
Other10 in. weld flange quantity of bolts / bolt hole diameter D12, 25.40mm (1.00 in.)
Other12 in. weld flange bolt circle diameter B431.80mm (17.00 in.)
Other12 in. weld flange outside diameter C482.6mm (19.0 in.)
Other12 in. weld flange quantity of bolts / bolt hole diameter D12, 25.40mm (1.00 in.)
Other14 in. weld flange bolt circle diameter B476.25mm (18.75 in.)
Other14 in. weld flange outside diameter C533.4mm (21.0 in.)
Other14 in. weld flange quantity of bolts / bolt hole diameter D12, 28.58mm (1.13 in.)
Other16 in. weld flange bolt circle diameter B539.75mm (21.25 in.)
Other16 in. weld flange outside diameter C596.9mm (23.5 in.)
Other16 in. weld flange quantity of bolts / bolt hole diameter D16, 28.58mm (1.13 in.)
Other18 in. weld flange bolt circle diameter B577.85mm (22.75 in.)
Other18 in. weld flange outside diameter C635.0mm (25.0 in.)
Other18 in. weld flange quantity of bolts / bolt hole diameter D16, 31.75mm (1.25 in.)
Other20 in. weld flange bolt circle diameter B635.00mm (25.00 in.)
Other20 in. weld flange outside diameter C698.5mm (27.5 in.)
Other20 in. weld flange quantity of bolts / bolt hole diameter D20, 31.75mm (1.25 in.)
Other5 in. weld flange bolt circle diameter B215.90mm (8.50 in.)
Other5 in. weld flange outside diameter C241.30mm (9.50 in.)
Other5 in. weld flange quantity of bolts / bolt hole diameter D8, 22.23mm (0.88 in.)
Other6 in. weld flange bolt circle diameter B254.0mm (10.0 in.)
Other6 in. weld flange outside diameter C279.4mm (11.0 in.)
Other6 in. weld flange quantity of bolts / bolt hole diameter D8, 22.23mm (0.88 in.)
Other8 in. weld flange bolt circle diameter B298.45mm (11.75 in.)
Other8 in. weld flange outside diameter C342.9mm (13.5 in.)
Other8 in. weld flange quantity of bolts / bolt hole diameter D8, 22.23mm (0.88 in.)
OtherBattery acid cleanup solution500 g (1 lb.) bicarbonate of soda to 4 L (1 gal.) water
OtherCoolant sample bottle minimum volume250ml (8.5 oz.)if no laboratory-supplied bottle
OtherCoolant sample volume1liter (1 qt.)collect after allowing about one liter to flow out
OtherDEF filter fill volume2/3full with DEFto help prime DEF system
OtherFan bearing greaseLithium grease with EP additive, NLGI 2suitable for -28°C to +121°C (-20°F to +250°F)
OtherGrease quantity 1-1/2 in. to 1-11/16 in. shaft9.5 (.32)ml (Oz.)approximate quantity
OtherGrease quantity 1-1/8 in. to 1-1/4 in. shaft3.0 (.10)ml (Oz.)approximate quantity
OtherGrease quantity 1-3/4 in. to 2 in. shaft14.8 (.50)ml (Oz.)approximate quantity
OtherGrease quantity 1-3/8 in. to 1-7/16 in. shaft6.5 (.22)ml (Oz.)approximate quantity
OtherGrease quantity 2 in. to 2-3/16 in. shaft16.3 (.55)ml (Oz.)approximate quantity
OtherGrease quantity 2-1/4 in. to 2-1/2 in. shaft19.2 (.65)ml (Oz.)approximate quantity
OtherGrease quantity 2-11/16 in. to 3 in. shaft25.1 (.85)ml (Oz.)approximate quantity
OtherGrease quantity 3-15/16 in. to 4 in. shaft74.0 (2.50)ml (Oz.)approximate quantity
OtherGrease quantity 3-3/16 in. to 3-1/2 in. shaft37.0 (1.25)ml (Oz.)approximate quantity
OtherGrease quantity 4-15/16 in. to 5 in. shaft140.5 (4.75)ml (Oz.)approximate quantity
OtherGrease quantity 4-7/16 in. to 4-1/2 in. shaft91.7 (3.10)ml (Oz.)approximate quantity
OtherOil sample bottle minimum volume125ml (4.3 oz.)if no laboratory-supplied bottle
OtherRTC battery life APM60310 years powered; 2 years not powered
OtherRTC battery life APM8023 yearspowered by engine battery
OtherRestriction gauge installation wrench16mmuse to install or remove restriction gauge
OtherWeld flange angle A (10, 12, 14 in. nominal pipe size)30deg.
OtherWeld flange angle A (16, 18, 20 in. nominal pipe size)22.5deg.
OtherWeld flange angle A (5, 6, 8 in. nominal pipe size)45deg.
SpeedFan belt tension KD2000-KD2500 High Ambient New Belt (10301001101-MA4 Module)67.4-69.7HzNew Belt; deflection 58.7-62.7 N @ 9 mm (13.1-14.0 lbs @ 0.4 in.)
SpeedFan belt tension KD2000-KD2500 High Ambient Used Belt62.4-64.9HzUsed Belt; deflection 50.8-54.8 N @ 9 mm (11.4-12.3 lbs. @ 0.4 in.)
SpeedFan belt tension KD2000-KD2500 Low Ambient New Belt (10301001101-MA3 Module)61.5-63.7HzNew Belt; deflection 51.1-54.5 N @ 9 mm (11.5-12.2 lbs @ 0.4 in.)
SpeedFan belt tension KD2000-KD2500 Low Ambient Used Belt57.0-59.3HzUsed Belt; deflection 44.2-47.6 N @ 9 mm (9.9-10.7 lbs. @ 0.4 in.)
SpeedFan belt tension KD2800-KD3250 Low Ambient New Belt (10301003601-MA3 Module)52.9-54.8HzNew Belt; deflection 63.3-67.6 N @ 12 mm (14.2-15.1 lbs @ 0.5 in.)
SpeedFan belt tension KD2800-KD3250 Low Ambient Used Belt49.0–51.0HzUsed Belt; deflection 54.8-59.0 N @ 12 mm (12.3-13.2 lbs. @ 0.5 in.)
SpeedFan belt tension KD3500-KD4000 New Belt (10301005801-MA1 Module)61.4-63.6HzNew Belt; deflection 79.7-85.2 N @ 12 mm (17.9-19.1 lbs @ 0.5in.)
SpeedFan belt tension KD3500-KD4000 Used Belt56.0–51.0HzUsed Belt; deflection 68.8-74.3 N @ 12 mm (15.5-16.7 lbs @ 0.5 in.)
TorqueDEF filter30 Nm (22 ft. lbs.)after seal contacts filter manifold, turn additional 120°
TorqueDEF injector nuts17 Nm (12.5 ft. lbs.)use bolt tightening pattern

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
DefISO 22241-4Fill neck uses ISO 22241-4 fill nozzle with 190-micron filter. Store in locked cabinet.
GreaseLithium grease with EP additive, NLGI 2-28°C to 121°CFor radiator fan bearings (KD2000-KD4000). Discontinue re-lubrication when clean grease purges through seal.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

1
CodeNameMeaningSeverityAction
M3.212APM INTERNAL BATTERY WARNINGBattery power is low on APM802 controllerWarningHave an authorized Rehlko service representative service the controller.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Notched V-Belt Adjustment (KD2000-KD4000) adjustment

⚠ Hazardous voltage. Moving parts. Operate only when all guards and electrical enclosures are in place.

Tools: sonic tension meter, wrench

  1. Disable generator set and remove from service.
  2. Remove fan guard rear face panel; inspect fan drive belt and replace if damaged or worn.
  3. Check fan belt tension using sonic tension meter or belt deflection method.
  4. Loosen four 3/4 in. undercarriage bolts.
  5. Adjust tensioner pulley along tensioner slots via lead screw.
  6. Adjust until belt tension falls into range listed in Figure 24.
  7. Check pulley alignment on fan shaft; adjust fan sheaves and tensioner sheaves.
  8. Tighten 3/4 in. undercarriage bolts; reinstall belt guards; reconnect battery; test run.
Air Filter Element Replacement maintenance
  1. Disable generator set and remove from service.
  2. For standard-duty filters: loosen clamp, remove element from air intake elbow, replace, tighten clamp.
  3. For heavy-duty filters: release cover clips (KD2000-KD2500) or remove wingnut (KD2800-KD4000), remove cover.
  4. Remove filter element.
  5. Clean internal components with damp cloth.
  6. Install new element.
  7. Replace cover; for KD2000-KD2500 point dust ejector downward.
Battery Clean maintenance

⚠ Sulfuric acid in batteries. Wear protective goggles and clothing.

Tools: wire brush

  1. Clean battery and cables and tighten terminals according to service schedule.
  2. Wipe battery with damp cloth; keep connections dry and tight.
  3. If corrosion exists, disconnect cables and remove corrosion with wire brush.
  4. Clean battery and cables with baking soda and water solution; do not allow solution to enter cells.
  5. Flush with clean water and wipe with dry cloth.
  6. After reconnecting cables, coat terminals with petroleum jelly, silicon grease, or other nonconductive grease.
Cooling System Drain maintenance

⚠ Hot coolant and steam. Stop generator set and allow to cool before removing pressure cap.

  1. Disable generator set and remove from service.
  2. Allow engine to cool.
  3. Remove pressure cap to allow system to drain and prevent air pockets.
  4. Open radiator and/or engine block coolant drain valve(s) and allow system to drain.
  5. On KD2000-KD4000, use engine drainage ports to drain coolant from water pumps and oil cooler.
  6. If radiator has mineral deposits or coolant contains dirt/grease, flush and clean cooling system.
  7. Otherwise proceed to refill cooling system.
Cooling System Refill maintenance

⚠ Hot coolant and steam. Do not add coolant to a hot engine.

  1. Remove pressure cap.
  2. Close radiator and/or engine block coolant drain valve(s) and tighten hose clamps.
  3. Fill cooling system with recommended coolant/antifreeze mixture.
  4. Fill coolant expansion tank to middle of sight glass.
  5. For KD2000-KD4000, use manual engine venting ports to bleed trapped air.
  6. Leave radiator cap off and run for 5 minutes with no load.
  7. Stop engine and allow to cool; check and repair leaks.
  8. Add coolant to just below overflow tube opening; replace pressure cap; operate until thermostat opens.
DEF Filter Replacement maintenance

⚠ Handling diesel exhaust fluid. Can cause skin, eye, respiratory irritation.

Tools: strap wrench or filter wrench, anti-static gloves, goggles

  1. Disable generator set and remove from service; wear anti-static gloves and goggles.
  2. Disconnect wiring harness from sleeve.
  3. Remove three screws and loosen and remove sleeve.
  4. Remove filter; use strap wrench or filter wrench if needed.
  5. Clean surrounding surfaces of DEF filter and manifold.
  6. Replace O-ring on filter manifold; lubricate with P80 or DEF.
  7. Lubricate seal of new filter with DEF or distilled water; fill new filter about 2/3 full with DEF; thread onto manifold.
  8. Tighten filter to 30 Nm (22 ft. lbs.) then additional 120°; reinstall sleeve; reconnect harness; reset run time in Kodia; run 30 minutes.
Draining Water from Fuel/Water Separator maintenance

⚠ Explosive fuel vapors. Use extreme care when handling fuels.

  1. Disable generator set and remove from service.
  2. Hold suitable container beneath fuel/water separator.
  3. Open vent plug and manually operated drain.
  4. Close drain when fuel free of water flows from separator.
  5. Use manual primer pump to prime filter until fuel flows from vent plug.
  6. Close vent plug.
Radiator Fan Bearing Lubrication (KD2000-KD4000) maintenance

⚠ Hazardous voltage. Moving parts. Operate only when all guards and electrical enclosures are in place.

Tools: grease gun

  1. Disable generator set and remove from service.
  2. Inject grease at remotely located grease fittings on left-hand side of radiator.
  3. Grease slowly to prevent over-greasing.
  4. Remove any excess grease.
  5. Reconnect engine starting battery(ies), negative lead last, and return to service.
Replacing Fuel/Water Separator Filter Element maintenance

⚠ Explosive fuel vapors. Use extreme care when handling fuels.

Tools: strap wrench or filter wrench

  1. Disable generator set and remove from service.
  2. Close fuel shut-off valve if present.
  3. Disconnect fuel-in-water sensor.
  4. Open vent plug and remove water drain plug to drain fuel.
  5. Remove element from mounting head by twisting counterclockwise.
  6. Remove bowl from element; inspect components; lubricate O-ring with clean diesel fuel.
  7. Install bowl onto new element; lubricate and install assembly onto mounting head.
  8. Replace drain plug; connect sensor; open fuel valve; prime with manual primer pump.
ON Load Test operation

⚠ Hazardous voltage. Moving parts. Operate only when all guards and electrical enclosures are in place.

  1. Operate generator set under load for 30–60 minutes maintaining exhaust temperature at rated kW.
  2. Apply voltage and check for alarms or faults.
  3. Check for leaks, vibrations, or abnormal noises.
  4. Ensure exhaust gas color is normal.
  5. Check engine parameters (oil pressure, coolant temperature).
  6. Check electrical parameters (voltage, frequency, current, rotating magnetic field).
  7. If fitted, check automatic filling devices (fuel or oil).
Start Test for Conscious Care™ Maintenance Plan operation

⚠ Hazardous voltage. Moving parts. Operate only when all guards and electrical enclosures are in place.

  1. Operate generator set for minimum 10 minutes under no-load or low-load conditions.
  2. If faults are indicated, correct and acknowledge them.
  3. If fitted, check pre-heating system works properly.
  4. Check for leaks, vibrations, or abnormal noises.
  5. Ensure exhaust gas color is normal.
  6. Check engine parameters (oil pressure, coolant temperature).
  7. Check electrical parameters (voltage, frequency, current, rotating magnetic field).
  8. If fitted, check automatic filling devices (fuel or oil).
DEF Injector Replacement repair

⚠ Handling diesel exhaust fluid. Can cause skin, eye, respiratory irritation.

⚠ Hot engine and exhaust system. Do not work until it cools.

Tools: anti-static gloves, goggles, torque wrench

  1. Disable generator set and remove from service; wear anti-static gloves and goggles.
  2. Disconnect DEF supply line by disengaging connector clip; disconnect wiring harness.
  3. Unbolt and remove nuts and washers securing DEF injector and plate to SCR module.
  4. Remove DEF injector and plate.
  5. Disconnect DEF return line by pressing both buttons and pulling.
  6. Remove gasket from SCR surface; clean debris from plate, injector, and SCR surfaces.
  7. Install new injector: position gasket, mounting plate, align holes, apply anti-seize to studs, tighten nuts to 17 Nm (12.5 ft. lbs.).
  8. Connect supply and return lines; enter slope and offset data into KODIA; reset run time; run 30 minutes.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Kohler KD1750?

The Kohler KD1750 is rated 1440 kW standby (1800.0 kVA).

What engine is in the Kohler KD1750?

The Kohler KD1750 is powered by the Kohler KD45V20 engine.

What kind of fuel does the Kohler KD1750 run on?

The Kohler KD1750 runs on Diesel.

What is the oil capacity of the Kohler KD1750?

The Kohler KD45V20 engine in the Kohler KD1750 has an oil capacity of 45.0 liters.

What is the coolant capacity of the Kohler KD1750?

The Kohler KD1750 cooling system holds 285 liters (75.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the Kohler KD1750?

The Kohler KD1750 is rated 1296 kW prime (1620 kVA), against 1440 kW standby.

How big is the fuel tank on the Kohler KD1750?

The Kohler KD1750 has a 5863 liter (1549 US gallon) fuel tank.

What voltages is the Kohler KD1750 available in?

The Kohler KD1750 is offered in 220/380 V, 230/400 V, 240/415 V, 1905/3300 V, 3-phase.

How many cold cranking amps does the Kohler KD1750 require?

The Kohler KD1750 uses 4 batteryies, 12 V each, 1110 CCA, per the manufacturer specification sheet.

What alternator does the Kohler KD1750 use?

The Kohler KD1750 uses a KH04920TO4D, KH05641TO4D, KH05740TO4D, KH06400TO4D, KH06721TO4D, KH06810TO4D alternator.

Which oil filter part number does the Kohler KD1750 take?

The Kohler KD1750 uses oil filter part number 230510001.

What fuel filter does the Kohler KD1750 use?

The Kohler KD1750 uses fuel filter part numbers 330510016, 230510004.

What air filter fits the Kohler KD1750?

The Kohler KD1750 uses air filter part number 10801001001.

Troubleshooting

1

Fault codes

CodeMeaning
M3.212APM INTERNAL power BATTERY WARNING

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

1
Part #DescriptionQtySystem
230612898Fuel Line Replacement Kit1Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime25%89.023.6
Prime50%165.043.5
Prime75%241.063.7
Prime100%324.085.5
Standby25%96.025.4
Standby50%180.047.6
Standby75%265.070.0
Standby100%355.093.9

Available documents

Engine spec — WPC PO-6504 -KD1000 Submittal (Perkins)Spec sheet — g5600 (Kohler)Reference — G6-39 0918AZ (Kohler)Reference — KDSeries-NFPAReference — KDSeries-maintenReference — KDSeries-overhaulReference — KDSeries-prodReference — g6167 (Kohler)Reference — subasta-uprp-22-01-generador-electrico-biblioteca-uprp-pagina (Kohler)Parts manual — KD Series Quicksheet Filters (Kohler)Parts manual — KD45V20 SPARES (Kohler)Parts manual — PB155 (Kohler)Parts manual — tp7056 (Kohler)Service manual — TP-7071 0618B (Kohler)Service manual — TP-7079Service manual — g12-478-sea-09-23 kd-series-800--4600-kva-catalog (Kohler)Service manual — subasta-uprp-22-04-generador-electrico-biblioteca-uprp (Kohler)Service manual — tp7143 (Kohler)

This page was generated from the 18 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter 10801001001$242.77
Fuel filter (primary) 330510016$33.15
Fuel filter (secondary) 230510004$40.00
Oil filter 230510001$40.80