Home›Repair guides›Kohler›Battery Clean

Kohler — Battery Clean

Maintenance · Battery system

From a Kohler service manual covering: KD1250-4, KD1750, KD2000, KD2500, KD3250, KD4000, KD700-KD4000, TP-7143. Check it applies to your exact model before use.

Applies to: Kohler KD1250-4, Kohler KD1750, Kohler KD2000, Kohler KD2500, Kohler KD3250, Kohler KD4000

Before you start

  • Sulfuric acid in batteries. Wear protective goggles and clothing.

Procedure

  1. Clean battery and cables and tighten terminals according to service schedule.
  2. Wipe battery with damp cloth; keep connections dry and tight.
  3. If corrosion exists, disconnect cables and remove corrosion with wire brush.
  4. Clean battery and cables with baking soda and water solution; do not allow solution to enter cells.
  5. Flush with clean water and wipe with dry cloth.
  6. After reconnecting cables, coat terminals with petroleum jelly, silicon grease, or other nonconductive grease.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler KD1250-4 →, Kohler KD1750 →, Kohler KD2000 →, Kohler KD2500 →, Kohler KD3250 →, Kohler KD4000 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →