Specifications
| Fuel | NG/LP |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 14 kW |
| Controller | Evolution |
| Oil capacity | 2.1 L |
| Voltage options | 240 V |
| Phase | 1 |
| Rated current | 58.3 A |
| Power factor | 1 |
| Circuit breaker | 60 A |
| Battery group | 26R |
| Battery cranking | 540 CCA |
| Battery voltage | 12 V |
| Dimensions (L×W×H) | 1219×635×737 mm |
| Dry weight | 175 kg |
| Sound level | 65.0 dBA @ 7 m |
Engine
| Oil capacity | 2.1 L |
|---|---|
| Displacement | 0.816 L |
| Aspiration | air-cooled |
| Rated speed | 3600 rpm |
Maintenance & consumables
for the Generac G-Force 800 Series| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Oil | 2.4 L | — | 200 hr |
Common questions
What is the power rating of the Generac G007224-0?
The Generac G007224-0 is rated 14 kW standby.
What engine does the Generac G007224-0 use?
The Generac G007224-0 is powered by the Generac G-Force 800 Series engine.
What fuel does the Generac G007224-0 use?
The Generac G007224-0 runs on NG/LP.
What is the oil capacity of the Generac G007224-0?
The Generac G-Force 800 Series engine in the Generac G007224-0 has an oil capacity of 2.1 liters.
Troubleshooting
5Fault codes
| Code | Meaning | Cause | Remedy |
|---|---|---|---|
| GeneratorVoltageImbalance OR GeneratorComBusPhaseDifferenceOOR | Generator was overloaded. | Generator breaker in IQ System Controller tripped, and the generator is disconnected. | The system will try to reconnect the generator in 5 minutes. You should: • Open IQ System Controller door, turn off the generator breaker and turn it on again. (When you open IQ System Controller, the generator breaker lever will not be in ON position) • Ensure you do not overload the system while the generator is running. |
| EnpowerGeneratorVoltHighTrip OR EnpowerGeneratorVoltLowTrip OR EnpowerGeneratorFreqHighTrip OR EnpowerGeneratorFreqLowTrip | Generator voltage and/or frequency out of spec while in generator mode and generator is connected | The generator gets disconnected | |
| GeneratorStartFailed | Generator not starting | The generator does not start as selected in user preferences. | Check if the generator 2-wire start/stop wiring to IQ System Controller is loose. Check whether the generator breaker at the unit was tripped (if so turn the breaker off and then on. Also switch the controller to the auto position), whether the generator is out of fuel, or the starting battery of the generator was dead. Contact your installer or Enphase customer support if the problem persists. |
| GeneratorStopFailed | Generator not stopping | Generator continues to run even though user preferences indicate it should have stopped. | Check if the generator 2-wire start/stop wiring to IQ System Controller is loose. Turn off the generator manually and contact installer or Enphase customer support. |
| GenTHDHigh | High Total Harmonic Distortion (THD) Measured THD is above 25% | Generator power output is not stable and having high THD (THD means total harmonic distortion, which is a metric to measure the power quality. If the THD is high, the performance of your electronics will be affected; for example, you may see flickering lights). |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
21| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 070185ES | Engine oil filter, spin-on | 1 | Oil filter | Amazon eBay $23.00 PartsGeek |
| 070185F | Engine oil filter | 1 | Oil filter | Amazon eBay $14.99 PartsGeek |
| 0C8127 | Air filter element | 1 | Air filter | Amazon eBay $28.00 PartsGeek |
| 0G0767A | Spark plug, gap 1.02mm (0.040in) | 2 | Spark plug | Amazon eBay $22.95 PartsGeek |
| 0J8478S | Air filter | 1 | Air filter | Amazon eBay $17.99 PartsGeek |
| 24 590 01-A | Oil Cooler, 14RCA/L | Oil cooler | PartsGeek | |
| A0006487350 | AGM Group BTX20L Battery | Battery | Amazon eBay PartsGeek | |
| G007009-0 | LTE LP Tank Fuel Level Monitor | Sensor | Amazon eBay PartsGeek | |
| RC14YC | Spark plug (V-twin GT-990, one per cylinder) | 2 | Spark plug | Amazon eBay $6.77 PartsGeek |
| 0D7178T | Control panel fuse, 7.5A | 1 | Service part / kit | PartsGeek |
| 0H3421S | Battery, ExideR, 12V, 540 CCA min (or AGM 650 CCA min) | 1 | Service part / kit | Amazon eBay $283.32 PartsGeek |
| G005621-0 | Auxiliary Transfer Switch Contact Kit | Service part / kit | Amazon eBay PartsGeek | |
| G006484-0 | Maintenance Kit | Service part / kit | PartsGeek | |
| G007000-1 | Generac Load Manager (50 amp) | Service part / kit | Amazon eBay $125.00 PartsGeek | |
| G007006-1 | Generac Load Manager (100 amp) | Service part / kit | Amazon eBay PartsGeek | |
| G007102-1 | Oil Heater | Service part / kit | Amazon eBay PartsGeek | |
| G007103-2 | Breather Heater | Service part / kit | Amazon eBay PartsGeek | |
| G007211-0 | Battery Heater | Service part / kit | Amazon eBay PartsGeek | |
| G007216-0 | Scheduled Maintenance Kit | Service part / kit | Amazon eBay $56.48 PartsGeek | |
| G009918-0 | Touch-Up Paint Kit | Service part / kit | Amazon eBay PartsGeek | |
| GM19463 | Carburetor Heater for 14 kW Models | 2 | Service part / kit | PartsGeek |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 50% | 0.97 | |
| Standby | 100% | 1.48 |