Specifications
| Fuel | Diesel |
|---|---|
| Standby power | 80 kW |
| Prime power | 80 kW |
| Oil capacity | 14.7 L |
| Voltage options | 400 V |
| Phase | Single |
| Rated current | 145 A |
| Power factor | 0.8 |
| Battery voltage | 12 V |
| Coolant capacity | 20 L |
| Dimensions (L×W×H) | 2774×1230×1665 mm |
| Dry weight | 2130 kg |
| Sound level | 95.0 dBA |
| Fuel tank | 280.0 L |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Clean air filter when restriction indicator (A) is red. Air filter can be cleaned up to six times. Thereafter, or at least once a year, it must be replaced. | — | 2000 hr | find | |
| Fuel filter | Change fuel filter every 100 hours or as needed. | 46553976 | 2000 hr | PartsGeek | |
| Oil filter | — | 2000 hr | find | ||
| Belt | Replace Fan/Alternator Poly-V Belt. Figure 64: Fan/Alternator Belt Installation on 4045 Engine. Figure 65: Fan/Alternator Belt Installation on 6068 Engine. | — | 2000 hr | find | |
| Coolant | — | 2000 hr | |||
| Coolant filter | — | 3000 hr | find | ||
| Oil | — | 500 hr |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Common questions
What is the power rating of the Doosan G100-SIIIA?
The Doosan G100-SIIIA is rated 80 kW standby.
What engine does the Doosan G100-SIIIA use?
The Doosan G100-SIIIA is powered by the John Deere 4045HFG82 engine.
What fuel does the Doosan G100-SIIIA use?
The Doosan G100-SIIIA runs on Diesel.
Parts
1| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 46606373 | 1 | Service part / kit | PartsGeek |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | |||
| Standby |