Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 1500 kW |
| Standby kVA | 1875 |
| Prime power | 1364 kW |
| Emissions | EPA Tier 2 |
| Controller | PowerCommand 3.3, PowerCommand 3.3 ( Capable) |
| Oil capacity | 117.0 L |
| Alternator | S7L1D-C4 (4-pole, Class Class H insulation) |
| Voltage options | 277/480 V, 220/380 V, 225/440 V, 347/600 V, 2400/4160 V, 3810/6600 V, 3637/6300 V, 3983/6900 V, 6350/1100 V |
| Phase | 3 |
| Power factor | 0.8 |
| Circuit breaker | 2500 A |
| Battery voltage | 24 volts, negative ground V |
| Coolant capacity | 272 L |
| Max ambient | 40 °C |
| Dimensions (L×W×H) | 5085×2184×2406 mm |
| Dry weight | 9231 kg |
| Wet weight | 9721 kg |
| Sound level | 95.1 dBA @ 7 m |
| Tank runtime | 24 hr |
Engine
| Oil capacity | 117.0 L |
|---|---|
| Coolant capacity | 272.0 L |
| Displacement | 37.8 L |
| Aspiration | Turbocharged and low temperature after-cooled |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the Cummins/Onan QSK38-G18| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | ||||
| Fuel filter | — | ||||
| Oil filter | — | ||||
| Battery | — | ||||
| Belt | — | ||||
| Coolant | — | ||||
| Oil | — | ||||
| Spark plug | — |
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Fuel | 40-50 Cetane number | ASTM D975 No. 2-D | 300-500 ppm Sulfur | ||
| Fuel | 40-50 Cetane number, ASTM D975 No. 2-D | ASTM D975 | 300-500 ppm Sulfur; #2 Diesel low-sulfur/ultra-low sulfur required for start-up |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
9| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 27 | Low AC voltage shutdown | Voltage on any phase has dropped below a preset value. Adjustable over a range of 50-95% of reference voltage, time delay 2-20 seconds. Default value is 85% for 10 seconds. Function tracks reference voltage. Control does not nuisance trip when voltage varies due to the control directing voltage to drop, such as during a V/Hz roll-off or synchronizing. | Shutdown | Shutdown genset. |
| 32 | Reverse power shutdown | Adjustment range: 5-20% of standby kW rating, delay 1-15 seconds. Default: 10%, 3 seconds. | Shutdown | Shutdown genset. |
| 40 | Reverse Var shutdown | Shutdown level is adjustable: 15-50% of rated Var output, delay 10-60 seconds. Default: 20%, 10 seconds. | Shutdown | Shutdown genset. |
| 46 | Negative sequence overcurrent warning | Control protects the generator from damage due to excessive imbalances in the three phase load currents and/or power factors. | Warning | Warning. |
| 51 | Overcurrent warning/shutdown | Implementation of the thermal damage curve with instantaneous trip level calculated based on current transformer ratio and application power rating. | Shutdown | Shutdown or warning. |
| 51G | Ground fault overcurrent | Control detects a ground fault either by an external ground fault relay via a contact input or the control can measure the ground current from an external current transformer. Associated time delays and thresholds are adjustable via InPower or HMI. | Shutdown | Shutdown or warning. |
| 59 | High AC voltage shutdown | Output voltage on any phase exceeds preset values. Time to trip is inversely proportional to amount above threshold. Values adjustable from 105-125% of nominal voltage, with time delay adjustable from 0.1-10 seconds. Default value is 110% for 10 seconds. | Shutdown | Shutdown genset. |
| 81 u | Under frequency shutdown | Genset output frequency cannot be maintained. Settings are adjustable from 2-10 Hz below reference governor set point, for a 5-20 second time delay. Default: 6 Hz, 10 seconds. Under frequency protection is disabled when excitation is switched off, such as when engine is operating in idle speed mode. | Shutdown | Shutdown genset. |
| 81o | Over frequency shutdown/warning | Genset is operating at a potentially damaging frequency level. Settings are adjustable from 2-10 Hz above nominal governor set point for a 1-20 second time delay. Default: 6 Hz, 20 seconds, disabled. | Warning | Warning or shutdown. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
1Series C4E-1D Cast Iron Spring-Flex Mounting Installation installation
Tools: Wrench
- Space and arrange isolators per installation drawings; ship fully assembled.
- Set isolators on floor or sub-base; align centerlines with equipment mounting holes.
- Shim or grout as required; level all base plates at same elevation (1/4 in max difference).
- Unless specified, mountings need not be fastened to floor. If required, bolt through slots.
- Remove adjusting bolt C with nut B from top housing A; do not discard.
- Place machine onto top plate A; weight lowers upper housing onto lower housing.
- Align equipment mounting hole to top housing tapped hole.
- Turn nuts B up on leveling bolts so they will not interfere with leveling.
- Insert bolts C through machine base holes and hand-screw into tapped hole as far as possible.
- Adjust each isolator in sequence: screw down one complete turn on adjusting bolt.
- Adjust until 1/4 in gap is obtained on all mounts.
- Turn nut on adjusting bolt C down against machine leg and lock with wrench.
- Installation is complete.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
How many kW is the Cummins/Onan C1500D6E?
The Cummins/Onan C1500D6E is rated 1500 kW standby (1875.0 kVA).
What engine does the Cummins/Onan C1500D6E use?
The Cummins/Onan C1500D6E is powered by the Cummins/Onan QSK38-G18 engine.
What kind of fuel does the Cummins/Onan C1500D6E run on?
The Cummins/Onan C1500D6E runs on Diesel.
What's the oil capacity on a Cummins/Onan C1500D6E?
The Cummins/Onan QSK38-G18 engine in the Cummins/Onan C1500D6E has an oil capacity of 117.0 liters.
How much coolant does the Cummins/Onan C1500D6E hold?
The Cummins/Onan C1500D6E cooling system holds 272 liters (71.9 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Cummins/Onan C1500D6E?
The Cummins/Onan C1500D6E is rated 1364 kW prime (1705 kVA), against 1500 kW standby.
How loud is the Cummins/Onan C1500D6E?
The Cummins/Onan C1500D6E is rated at 95.1 dBA at 7 m, per the manufacturer specification sheet.
How much does the Cummins/Onan C1500D6E weigh?
The Cummins/Onan C1500D6E has a dry weight of 9231 kg (20350 lb).
What voltages is the Cummins/Onan C1500D6E available in?
The Cummins/Onan C1500D6E is offered in 277/480 V, 220/380 V, 225/440 V, 347/600 V, 2400/4160 V, 3810/6600 V, 3-phase.
Which alternator is fitted to the Cummins/Onan C1500D6E?
The Cummins/Onan C1500D6E uses a S7L1D-C4 alternator. It has 4 poles. Insulation class Class H.
Troubleshooting
2Symptoms & remedies
| Symptom | Remedy |
|---|---|
| Battle short mode | When enabled and the battle short switch is active, the control will allow some shutdown faults to be bypassed. If a bypassed shutdown fault occurs, the fault code and description will still be annunciated, but the genset will not shutdown. This will be followed by a fail to shutdown fault. Emergency stop shutdowns and others that are critical for proper operation (or are handled by the engine ECM) are not bypassed. |
| Derate | The Derate function reduces output power of the genset in response to a fault condition. If a Derate command occurs while operating on an isolated bus, the control will issue commands to reduce the load on the genset via contact closures or Modbus. If a Derate command occurs while in utility parallel mode, the control will actively reduce power by lowering the base load kW to the derated target kW. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
4| Part # | Description | Qty | System | |
|---|---|---|---|---|
| MCBQSK0068 | Water Pump Gasket Set | Gasket | Amazon eBay | |
| M-2885786 | Cylinder Liner Kit | Service part / kit | Amazon eBay | |
| M-3007525 | Cylinder Liner Kit | 1 | Service part / kit | Amazon eBay |
| M-3022157 | Cylinder Liner | 1 | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Continuous | 25% | 112.0 | 29.5 |
| Continuous | 50% | 196.0 | 51.8 |
| Continuous | 75% | 285.0 | 75.1 |
| Continuous | 100% | 361.0 | 95.3 |
| Prime | 25% | 112.0 | 29.5 |
| Prime | 50% | 196.0 | 51.8 |
| Prime | 75% | 285.0 | 75.1 |
| Prime | 100% | 361.0 | 95.3 |
| Standby | 25% | 120.0 | 31.7 |
| Standby | 50% | 215.0 | 56.8 |
| Standby | 75% | 310.0 | 81.9 |
| Standby | 100% | 388.0 | 102.5 |
Available documents