Specifications
Ratings spec sheet not in our library yet — see the documents below.
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Atlas Copco Roto-injectfluid or mineral oil with oxidation inhibitors and anti-foam and anti-wear properties, viscosity grade ISO VG 68 at above 25°C, ISO VG 46 between 25 and 0°C | — | 1000 hr | ||
| Fuel filter | Atlas Copco Roto-injectfluid or mineral oil with oxidation inhibitors and anti-foam and anti-wear properties, viscosity grade ISO VG 68 at above 25°C, ISO VG 46 between 25 and 0°C | — | 1000 hr | ||
| Oil filter | Atlas Copco Roto-injectfluid or mineral oil with oxidation inhibitors and anti-foam and anti-wear properties, viscosity grade ISO VG 68 at above 25°C, ISO VG 46 between 25 and 0°C | — | 1000 hr | ||
| Belt | — | ||||
| Coolant filter | Atlas Copco Roto-injectfluid or mineral oil with oxidation inhibitors and anti-foam and anti-wear properties, viscosity grade ISO VG 68 at above 25°C, ISO VG 46 between 25 and 0°C | — | 1000 hr | ||
| Oil | Atlas Copco Roto-injectfluid or mineral oil with oxidation inhibitors and anti-foam and anti-wear properties, viscosity grade ISO VG 68 at above 25°C, ISO VG 46 between 25 and 0°C | — | 1000 hr | ||
| Spark plug | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service intervals
15| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| air filter element (AF) | Clean | 500 hr | 3 mo | 3-monthly; remove, clean by air jet and inspect (section 5.1) |
| coolers (Co/Ca) and condenser of dryer | Clean | 500 hr | 3 mo | 3-monthly; check and clean if necessary (section 5.2) |
| oil and oil filter | Change | 1000 hr | 12 mo | If oil as specified in section 4.3.2 is used (sections 4.3/4.4) |
| restrictors (Rf1, Rf2) | Check | 2000 hr | 12 mo | Yearly; check for cleanness (section 4.6/5.1, note 6) |
| air filter element (AF) | Replace | 4000 hr | 12 mo | Yearly (section 4.6/5.1) |
| oil and oil filters | Change | 4000 hr | 12 mo | Yearly; if Atlas Copco Roto-injectfluid is used, For GA 7.5-8-10 bar and 100-125-150 psi (sections 4.3/4.4/4.6, note 4) |
| oil separator (OS) | Replace | 8000 hr | 24 mo | 2-yearly; have replaced, or when pressure drop over separator exceeds 1 bar (section 5, note 5) |
| LED/display test | Test | 3 mo | 3-monthly; note 7 | |
| bearings of drive motor | Lubricate | 12 mo | Yearly; re-grease as specified (section 4.1) | |
| electrical interlockings, motor breakers, etc. | Test | 12 mo | Yearly; by an electrician | |
| flexibles/flexible joints | Inspect | 12 mo | Yearly; have all inspected (note 9) | |
| float valve of condensate trap (MTa) | Clean | 3 mo | 3-monthly; remove, dismantle and clean | |
| possible leakages | Check | 3 mo | 3-monthly; note 10 | |
| safety valve (SV) | Test | 12 mo | Yearly; have tested (section 5.3) | |
| temperature shut-down function | Test | 12 mo | Yearly; note 8 |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
26| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Pressure | Fan control switch (PSR90) cut-out pressure | 16.9 | bar(e) | |
| Pressure | Fan control switch (PSR90) switch-on pressure | 18 | bar(e) | |
| Pressure | Max. cooling water inlet pressure | 5 | bar(e) | water-cooled units |
| Pressure | Minimum working pressure | 4 | bar(e) | |
| Pressure | Pressure difference over oil separator | Below 1 | bar | compressor running loaded |
| Pressure | Safety valve set pressure, GA 10 bar | 12 | bar(e) | |
| Pressure | Safety valve set pressure, GA 10 bar/ISPESL approved | 11 | bar(e) | |
| Pressure | Safety valve set pressure, GA 100 psi | 200 | psig | |
| Pressure | Safety valve set pressure, GA 125 psi | 200 | psig | |
| Pressure | Safety valve set pressure, GA 13 bar | 14.5 | bar(e) | |
| Pressure | Safety valve set pressure, GA 13 bar/ISPESL approved | 14 | bar(e) | |
| Pressure | Safety valve set pressure, GA 150 psi | 200 | psig | |
| Pressure | Safety valve set pressure, GA 175 psi | 215 | psig | |
| Pressure | Safety valve set pressure, GA 7.5-8 bar | 12 | bar(e) | |
| Pressure | Safety valve set pressure, GA 7.5-8 bar/ISPESL approved | 11 | bar(e) | |
| Pressure | Shut-down switch (PSHH90) | 29 | bar(e) | |
| Speed | Motor shaft speed (50 Hz) | 2970 | r/min | |
| Speed | Motor shaft speed (50 Hz) | 2975 | r/min | |
| Speed | Motor shaft speed (60 Hz) | 3575 | r/min | |
| Temperature | Compressor element outlet temperature | Approx. 60 degrees celsius above cooling air temperature or above cooling water inlet temperature | celsius | |
| Temperature | Cooling water outlet temperature | Below 50 | celsius | |
| Temperature | Max. cooling water outlet temperature | 50 | celsius | |
| Temperature | Maximum air inlet temperature | 40 | celsius | |
| Temperature | Minimum air inlet temperature | 0 | celsius | |
| Temperature | Pressure dewpoint, Full-feature | 3 | celsius | at 20 degrees celsius / 100% relative humidity |
| Temperature | Pressure dewpoint, Full-feature | 4 | celsius | at 20 degrees celsius / 100% relative humidity |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | Cooling water | Recommended maxima for recirculating/open systems (mg/l): Chloride <600/<150, Sulphate <400/<250, Total solids <3000/<750, Suspended solids (as SiO2) <10/<10, Free chlorine <4/<2, Ammonia <0.5/<0.5, Copper <0.5/<0.5, Iron <0.2/<0.2, Manganese <0.1/<0.1, Oxygen <3/<3, Carbonate hardness (as CaCO3) 50-1000/50-500, Organics (KMnO4) <25/<10; no algae, no oil | |||
| Grease | ASONIC HQ 72-102 | 16.0 g per bearing | High-temperature ball bearing grease for ABB motors; every 4,000 operating hours (every 3,400 operating hours for GA75 60 Hz) | ||
| Grease | ESSO UNIREX N3 | 40.0 g | For SIEMENS motors; bearings regreased every 4,000 operating hours | ||
| Other | Atlas Copco Roto-injectfluid | 29.5 l | Special oil for screw compressors, strongly recommended. Oil capacity GA = 29.5 l, GA W = 26 l | ||
| Other | Food grade oil | optional oil | |||
| Other | R410A | refrigerant for integrated dryer; zero ozone depletion | |||
| Other | Roto – Xtend duty oil | 8000 hours; optional oil | |||
| Other | ISO VG 46 | ISO 3448 | 0°C to 25°C | Mineral oil with oxidation inhibitors and anti-foam and anti-wear properties; viscosity index minimum 95; between 25 and 0 degrees celsius | |
| Other | ISO VG 68 | ISO 3448 | above 25°C | Mineral oil with oxidation inhibitors and anti-foam and anti-wear properties; viscosity index minimum 95; consistently above 25 degrees celsius |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
10Start-up installation
⚠ Before carrying out any maintenance, repair or adjustment, stop the compressor, press emergency stop button (S3), switch off the voltage and depressurize the compressor.
- Remove transport fixations (painted red): bushes (2) from both gear casing supports, bushes (5) from both air receiver supports, support (3).
- Check that electrical connections correspond to local codes and are tight; install earthing, short-circuit fuses in all phases and an isolating switch near the compressor.
- Check transformer (T1) connection, settings of overload relay (F21) and fan motor circuit breaker (Q15), and automatic resetting of (F21).
- Fit air outlet valve (AV), close it and connect the air net to the valve.
- Connect manual condensate drain valve (Dma), close it and connect it to a drain collector.
- Connect automatic condensate drain outlet (Daa) to the drain collector.
- Water-cooled: fit drain valves in water inlet and outlet pipes; provide and open the water inlet and regulating valve.
- Check oil level; pointer of level gauge (Gl) must register in the green or orange range; top up with Roto-injectfluid if needed.
- Stick the automatic restart and automatic control warning labels on an obvious place near the control panel.
- Switch on voltage, start and stop the compressor immediately; check rotation direction of drive motor (M1), then fan motor (M2); reverse two incoming lines if wrong.
- Check the programmed settings.
- Start and run the compressor for a few minutes; check that it operates normally.
Air filter maintenance
⚠ Before carrying out any maintenance, repair or adjustment, stop the compressor, press emergency stop button (S3), switch off the voltage and depressurize the compressor.
- Stop the compressor. Switch off the voltage. Release the snap clips and remove the dust trap and air filter element. Clean the trap. Discard the filter element.
- Refit the new element and the trap.
- Reset the service indicator (VI) by pushing the knob in the extremity of the body.
- Reset the air filter service warning.
Coolers maintenance
⚠ Stop compressor before cleaning coolers.
- Air-cooled compressors: remove any dirt from the coolers with a fibre brush; never use a wire brush or metal objects.
- Clean by air jet in reverse direction of normal flow while covering all compressor parts under the coolers.
- If washing with a cleansing agent is necessary, consult Atlas Copco.
- Water-cooled compressors: consult Atlas Copco for cleaning.
Oil and oil filter change maintenance
⚠ Never mix oils of different brands or types. Use only non-toxic oils.
⚠ Before carrying out any maintenance, repair or adjustment, stop the compressor, press emergency stop button (S3), switch off the voltage and depressurize the compressor.
- Run the compressor unloaded for 3 minutes.
- Stop the compressor. Switch off the voltage. Unscrew oil filler plug (FC) one turn only to release system pressure.
- Remove vent plug (VP), wait 5 minutes, remove drain plug (DP2) and catch the oil in a receptacle.
- Remove the oil filters (OF).
- Clean the filter seats on the manifold. Oil the gaskets of the new elements. Screw in until gaskets contact their seats, then tighten by hand (approx. half a turn).
- Drain the oil by removing drain plugs (DP1 and DP3); collect the oil and deliver it to the local oil collection service.
- Reinstall plugs (DP1 up to DP3) and fill the air receiver with oil until the level reaches the filler plug opening.
- Run the compressor for a few minutes; stop, wait a few minutes, depressurize, top up oil to the filler plug opening and tighten plug (FC).
- Reset the oil and oil filter service warnings.
Safety valve maintenance
⚠ No adjustments are allowed. Never run the compressor without safety valve.
- Operate the safety valve depending on the type of valve: by unscrewing the cap one or two turns and retightening it, or by pulling the valve lifting lever.
- The valve can be tested on a separate compressed air line; if it does not open at the specified pressure, consult Atlas Copco.
Before starting operation
- Check the oil level (Gl); the pointer should register in the green range or in the orange range.
- If the coloured part of the air filter service indicator (VI) shows full out, replace the air filter element (AF); reset the indicator and the service warning.
- Water-cooled only: check that the cooling water drain valves in the inlet and outlet pipes are closed.
- Water-cooled only: open the cooling water inlet valve.
- Water-cooled only: open the water flow regulating valve.
- If the compressor has not run for the past 6 months, pour 3/4 l of oil into the compressor element before starting.
During operation operation
⚠ Before carrying out any maintenance, repair or adjustment, stop the compressor, press emergency stop button (S3), switch off the voltage and depressurize the compressor.
- Check the oil level during loaded operation; the pointer of the level gauge (Gl) must register in the green range.
- If the level is in the LOW range, press the stop button, wait until the compressor has stopped and switch off the voltage; depressurize the oil system by unscrewing the oil filler plug (FC) one turn a
- If the coloured part of the air filter service indicator (VI) shows full out, stop the compressor, switch off the voltage and replace the air filter element (AF); reset the indicator and the service w
- Regularly check the display for readings and messages; remedy the trouble if alarm LED is alight or blinks.
Starting operation
⚠ A start command will be executed (if programmed and activated), even after manually stopping the compressor.
- GA Full-feature: switch on the voltage 4 hours before starting to energize the crankcase heater of the refrigerant compressor.
- Switch on the voltage. Check that voltage on LED lights up. The message <<compressor off>> appears.
- Open the air outlet valve (AV).
- Close the condensate drain valve (Dma).
- Press start button I. The compressor starts and automatic operation LED lights up; after 10 seconds the drive motor switches from star to delta and the compressor runs loaded.
- Water-cooled only: regulate the cooling water flow during loaded running to obtain the most suitable temperature at the compressor element outlet, between 2 and 7 degrees celsius above the relevant te
Stopping operation
- Press stop button O. LED goes out. The message <<Programmed stop>> appears. The compressor runs unloaded for 30 seconds and then stops.
- Emergency: press button S3. Alarm LED blinks. Remedy the fault, unlock the button by pulling it out and press key <<Rset>> before restarting.
- Close air outlet valve (AV) and switch off the voltage.
- Open condensate drain valve (Dma).
- Water-cooled only: close the cooling water inlet valve.
- Water-cooled only: if freezing temperatures may be expected, drain the cooling system completely.
Taking out of operation at end of compressor service life operation
- Stop the compressor and close the air outlet valve.
- Switch off the voltage and disconnect the compressor from the mains.
- Depressurize the compressor.
- Shut off and depressurize the part of the air net connected to the outlet valve; disconnect the compressor air outlet pipe from the air net.
- Isolate and disconnect the water system from the cooling water net.
- Drain the oil, water and condensate circuits.
- Disconnect the condensate piping from the condensate net.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Repair guides
7- Air filter
- During operation
- Oil and oil filter change
- Start-up
- Starting
- Stopping
- Taking out of operation at end of compressor service life
Step-by-step procedures compiled from the Atlas Copco service manual for this model.
Parts
1| Part # | Description | Qty | System | |
|---|---|---|---|---|
| PT20 | Pressure sensor, air outlet | 1 | Pressure sensor | Amazon eBay FridayParts $85.99 |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Available documents