Atlas Copco — Taking out of operation at end of compressor service life
Operation
From a Atlas Copco operator's manual covering: GA 10 bar, GA 100 psi, GA 125 psi, GA 13 bar, GA 150 psi, GA 175 psi, GA 7.5-8 bar, GA 75, GA5, GA90. Check it applies to your exact model before use.
Applies to: Atlas Copco GA 75
Procedure
- Stop the compressor and close the air outlet valve.
- Switch off the voltage and disconnect the compressor from the mains.
- Depressurize the compressor.
- Shut off and depressurize the part of the air net connected to the outlet valve; disconnect the compressor air outlet pipe from the air net.
- Isolate and disconnect the water system from the cooling water net.
- Drain the oil, water and condensate circuits.
- Disconnect the condensate piping from the condensate net.
Source: Atlas Copco operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.