HomeEnginesGenerac GN-570

Generac GN-570 Engine

The Generac GN-570 is a 0.57 L engine rated at 2500 rpm. It powers generator sets from Generac, including the Q-70G and Q-70LP. It holds 1.7 L (0.4 gal) of oil.

Also known as: Generac GN-570

0.57 L
Displacement
2500 rpm
Rated speed
1.7 L
Oil capacity

Engine specifications

Oil capacity1.7 L
Displacement0.57 L
Rated speed2500 rpm

Generator sets powered by this engine

2
Generac Q-70GGenerac Q-70LP

How to read your Generac engine serial & model number →

Common problems

15
  • The Start/Stop switch is set to Stop, but the engine continues to run.
    Cause: 1. Defective Start/Stop switch 2. Open/Disconnected #18 wire between Start/Stop switch and engine control board 3. Open/Disconnected #0 wire betw
    Fix: 1. Replace switch. 2. Reconnect or close wire. 3. Reconnect or close wire.
  • The engine will not crank.
    Cause: 1. Fuse blown 2. Loose, corroded or defective battery cables as necessary. 3. Defective engine Start/Stop switch 4. Defective starter contactor 5. Defective starter motor
    Fix: 1. Replace fuse. 2. Tighten, clean or replace battery cables as necessary. 3. Replace Start/Stop switch. 4. Replace contactor. 5. Replace starter motor.
  • The engine starts, but shuis down when the Start/Stop switch is released.
    Cause: 1. Engine oil level low 2. Defective low oil pressure switch 3. Defective high temperature switch 4. Defective engine control board 5. Overheated engine
    Fix: 1. Check oil and add oil as needed. 2. Replace pressure switch. 3. Replace temperature switch. 4. Replace control board. 5. Check that the airflow openings are adequate.
  • The engine starts hard and runs rough.
    Cause: 1. Air cleaner plugged or damaged
    Fix: Check, clean or replace air cleaner.
  • The engine cranks but will not start.
    Cause: 1. Out of fuel 2. Defective fuel pump 3. Open #14 wire from engine control board insulation of #14 wires. 4. Flooded engine 5. Defective spark plug(s) 6. Fuel line shut-off closed 7. Plugged fuel filter
    Fix: 1. Replenish fuel. 2. Replace fuel pump. 3. Check connections and/or insulation of #14 wires. 4. Wait 5-10 minutes before trying. 5. Clean, re-gap or replace plug(s). 6. Open fuel line shut-off. 7. Clean or replace fuel filter.
  • No AC output voltage
    Cause: 1. Main breaker(s) open. 2. Transfer switch (if so equipped) is set to wrong position. 3. Failure in vehicle electrical system. 4. Generator component failure.
    Fix: 1. Close main breaker(s). 2. Reset transfer switch. 3. See vehicle manual. 4. Contact authorized service facility.
  • Generator overheating and shutdown
    Cause: Insufficient cooling and ventilating air flow
    Fix: Ensure air inlet and outlet openings in generator compartment are open and unobstructed
  • Exhaust gases entering vehicle interior
    Cause: Openings in the vehicle that might permit exhaust gases to enter
    Fix: Close windows, doors, and other openings in the vehicle
  • Engine won’t crank
    Cause: 1. 15 amp fuse blown. 2. Loose, corroded or defective battery cable(s). 3. Battery is discharged or defective. 4. Defective starter contactor. 5. Defective starter motor. 6. Defective control relay (CR1).
    Fix: 1. Replace blown fuse. 2. Tighten, clean or replace, as necessary. 3. Recharge or replace battery. 4. Replace starter contactor. 5. - Replace starter motor. 6. Replace control relay.
  • Engine won't crank
    Cause: 1. 15 amp fuse blown. 2. Loose, corroded or defective battery 3. Transfer switch (if so equipped) is set to wrong position. 4. Failure in vehicle electrical system. 5. Generator component failure.
    Fix: 1. Replace blown fuse. 2. Tighten, clean or replace, as necessary. 3. Set transfer switch correctly if equipped. 4. Check and repair the vehicle's electrical system. 5. Inspect and replace any faulty generator components.
  • Engine starts, then shuts down
    Cause: 1. Engine oil level is low 2. Bad control relay (CR1). 3. Bad low oil pressure switch. 4. Bad control relay (CR2). 5. Water in fuel.
    Fix: 1. Add oil as needed. 2. Replace if bad (CR1). 3. Replace, if bad. 4. Replace bad relay (CR2). 5. Drain fuel tank and refill.
  • Engine starts hard, runs rough
    Cause: 1. Dirty engine air cleaner.
    Fix: 1. Clean or replace as needed.
  • Engine failure
    Cause: Attempted cranking or starting engine before proper oil servicing
    Fix: Properly service engine crankcase with recommended oil
  • Engine does not start after cranking for 15 seconds
    Fix: Release the start/stop switch and try again
  • Engine cranks, won’t start
    Cause: 1. Out of fuel. 2. Fuel shutoff valve is closed. 3. Fuel pump not operating. 4. Automatic choke not operating properly. 5. Engine is flooded. 6. Fuel filter is clogged. 7. Defective control relay (CR2). 8. Engine spark plugs defective. 9. Bad ignition magneto on engine. 10. Bad carburetor. 11. Dirty air cleaner.
    Fix: 1. Refill fuel tank. 2. Open fuel shutoff valve(s). 3. Repair or replace pump. 4. Repair, replace or adjust. 5. Wait 5*10 minutes; try again. 6. Replace filter if clogged. 7. Replace bad relay (CR2). 8. Clean, regap or replace as needed. 9. Replace if defective. 10. Adjust, repair or replace. 11. Clean or replace as needed.

Compiled from service & troubleshooting documentation across every generator set that uses the Generac GN-570.

Service intervals

32
ItemActionHoursMonthsNotes
Engine crankcase oil levelCheck8 hror before each use
Engine oil levelCheck8 hrat least every eight hours of operation, or before use
Air cleaner foam pre-cleanerClean25 hr3 moclean and re-oil; whichever occurs first; more often in dusty conditions
All fluid levelsCheck25 hrFirst service — 25-Hour Check Up
Cooling and ventilation openingsInspect25 hrFirst service — part of 25-hour check up
Cooling and ventilation openings on the vehicleInspect25 hrFirst service — 25-Hour Check Up
Electrical systemInspect25 hrFirst service — part of 25-hour check up
Engine carburetor adjustmentsCheck25 hrFirst service — part of 25-hour check up
Engine crankcase oil and oil filterChange25 hrFirst service — 25-hour check up, by authorized service facility
Engine exhaust systemInspect25 hrFirst service — part of 25-hour check up
Engine ignition systemCheck25 hrFirst service — part of 25-hour check up
Engine oil and oil filterChange25 hrFirst service — 25-hour check up.
Engine oil filterChange100 hrFirst service — After the 25-hour break-in period
Entire electrical systemInspect25 hrFirst service — Part of 25-Hour Check Up
Fluid levelsCheck25 hrFirst service — part of 25-hour check up
Foam pre-cleanerClean25 hr3 mowhichever occurs first
Foam precleanerClean25 hr3 moWhichever occurs first; more frequently in dusty/dirty conditions
Engine crankcase oilChange50 hrFirst service — Change more frequently under heavy load or high ambient temperatures
Engine oilChange50 hrFirst service — thereafter; more often under heavy load/high ambient
Air cleaner paper filterReplace100 hr12 mowhichever comes first; must be flame retardent type
Air intake screenClean100 hrat least every 100 hours; clean more often if necessary
Fuel filterReplace100 hr12 mowhichever comes first
Fuel filter (gasoline only)Replace100 hr12 moWhichever comes first
Oil filterReplace100 hrFirst service — every 100 operating hours thereafter
Paper air filterReplace100 hr12 mowhichever comes first
Spark plugClean100 hrReset spark plug gap to 0.030 inch (0.76 mm)
Spark plugsClean100 hrreset gap to 0.030 inch (0.8mm); do not blast clean
Generator exercise runTest168 hrStart and operate at least once every seven days; run at least 30 minutes
BatteryInspect1 moWeekly inspect posts, cables, fluid level.
BatteryTest6 moEvery six months check state of charge/condition with hydrometer.
Battery state of chargeTest6 moevery six months, by automotive service facility
Battery state of charge and conditionTest6 mohave checked by automotive service facility with battery hydrometer

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

43
TypeItemValueUnitCondition
GapSpark plug gap0.030inch (0.76 mm)
GapSpark plug gap0.8mm
OtherBonding conductorNo. 8 AWG copper wire minimumflexible conductor if replaced
OtherCompression ratio8.6 to 1
OtherEngine crankcase capacity1.5U.S. quarts
OtherEngine displacement480cc
OtherEngine displacement570cc
OtherFuel Pump Primer hold time30secondscold engine not started in more than two weeks
OtherGrounding conductor minimumNo. 8 AWGcopper wire
OtherMaximum cranking time15seconds
OtherOil capacity1.7liters
OtherRated horsepower19hp at 3600 rpm
OtherRated horsepower Q-55G15hpat 3600
OtherRated horsepower Q-70G18hpat 3600 rpm
OtherRated max. continuous AC output5500watts (5.5 kW)120 V
OtherRated max. continuous AC output7000watts (7.0 kW)120 V
OtherRated max. continuous current22.9AC amps240 V
OtherRated max. continuous current29.1AC amps240 V
OtherRated max. continuous current45.8AC amps120 V
OtherRated max. continuous current58.3AC amps120 V
OtherRotor poles2poles
PressureFuel inlet pressure required0.39PSI
PressureFuel inlet pressure required11inch WC
PressureLow oil pressure shutdownabout 8-10PSIoil pressure switch closes below this
PressureLow oil pressure shutdown switch2-6PSIcontacts close below this pressure
PressureLow oil pressure shutdown switch actuation8-10PSIbelow this pressure switch contacts close and engine shuts down
PressureLow oil pressure switch10 PSIPSI
PressureOil pressure shutdown2-6PSI
SpeedEngine governed speed2500rpm
SpeedEngine governor speed / engine RPM3000rpm
SpeedNumber of rotor poles2
SpeedRated horsepower16hp @ 3,600 rpm
SpeedRotor RPM3600rpm
SpeedRotor speed3600rpm
TemperatureHigh oil temperature shutdown284°F (140°C)
TemperatureHigh oil temperature shutdown switch284°F (140°C)contacts close above this temperature
TemperatureHigh temperature switch actuation (engine shutdown)approximately 284°F (140° C)
TorqueOil filter installation3/4 to one turnturn by handafter gasket contacts filter adapter
TorqueOil filter tightening after gasket contact3/4 to oneturnafter gasket lightly contacts adapter
VoltageAC output voltage regulation120voltsat 60 Hz
VoltageStarter system12volts DC electric
VoltageVoltage regulation at 50 Hertz115voltsAC frequency 50 Hertz
VoltageVoltage regulation at 60 Hz120Vvoltage-to-frequency ratio is 2-to-1

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Engine oilSAE 10W-30API classification "For Service SF"1.4 litersHigh quality detergent oil; do not pour in any additives. For storage refill use SAE 10W-30 with API classification "For Service SE"
FuelHigh quality UNLEADED gasoline; leaded REGULAR grade gasoline is an acceptable substituteDo not use gasoline containing alcohol (such as gasohol); if used, must not contain more than 10 percent ethanol and must be removed during storage. Do NOT use gasoline containing methanol
FuelLP gas (propane)LP-vapour withdrawal fuel system as standard; requires inlet pressure of 11" WC (0.39 PSI)
FuelUnleaded gasolineLeaded regular acceptable substitute. Do not use gasoline containing methanol. If alcohol, max 10% ethanol and remove during storage.
OtherBicarbonate of soda solution1.0 pound (500 grams) per 1 gallon (4 liters) of waterElectrolyte neutralizing agent
OtherDistilled waterFor battery cells only; DO NOT USE TAP WATER IN BATTERY

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
25-Hour Check Up maintenance
  1. After 25-hour break-in period, contact authorized service facility for maintenance.
  2. Change engine crankcase oil and oil filter.
  3. Check all fluid levels.
  4. Inspect cooling and ventilation openings on vehicle.
  5. Check engine carburetor adjustments.
  6. Check engine ignition system.
  7. Inspect entire electrical system.
  8. Inspect engine exhaust system.
Battery maintenance

⚠ DO NOT USE TAP WATER IN BATTERY.

⚠ STORAGE BATTERIES GIVE OFF EXPLOSIVE HYDROGEN GAS.

Tools: hydrometer

  1. Once weekly: Inspect battery posts and cables for tightness, corrosion. Clean and/or tighten as needed.
  2. Check battery fluid level; if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER.
  3. Every six months: Have battery state of charge and condition checked by automotive service facility with hydrometer.
Battery Inspection maintenance

⚠ Storage batteries give off explosive hydrogen gas.

⚠ Battery electrolyte is caustic sulfuric acid; wear protective goggles, clothing and gloves.

Tools: hydrometer, distilled water

  1. Once weekly, inspect battery posts and cables for tightness and corrosion.
  2. Clean and/or tighten as needed.
  3. Check battery fluid level and fill with distilled water only.
  4. Do not use tap water in the battery.
  5. Every six months have state of charge and condition checked by an automotive service facility.
Battery Inspection and Service maintenance

⚠ Storage batteries give off explosive hydrogen gas

⚠ Battery electrolyte is caustic sulfuric acid

Tools: Automotive type battery hydrometer

  1. Once weekly inspect battery posts and cables for tightness and corrosion.
  2. Clean and/or tighten as necessary.
  3. Check battery fluid level and fill with distilled water only.
  4. Every six months have state of charge and condition checked with an automotive hydrometer.
Change Engine Oil maintenance

⚠ DO NOT OVERFILL ABOVE FULL MARK.

Tools: suitable container

  1. Warm up engine for at least five minutes, then shut down.
  2. With engine still warm, remove oil drain plug. Drain oil completely into suitable container.
  3. Install and tighten oil drain plug.
  4. Remove oil dipstick and fill crankcase with recommended oil. Crankcase holds about 1.7 liters. Do not overfill.
  5. Install and tighten dipstick cap before operating engine.
Change Oil Filter maintenance

Tools: new oil filter

  1. Turn oil filter counterclockwise to remove.
  2. Coat gasket of new filter with engine oil.
  3. Turn new filter clockwise until gasket contacts tightly with filter adapter. Tighten additional 3/4 to one turn by hand.
  4. Run engine and check for leaks.
Changing Engine Oil maintenance

Tools: suitable container for drained oil

  1. Warm up engine for at least five minutes, then shut down.
  2. With engine still warm, remove oil drain plug and drain oil completely.
  3. Install and tighten oil drain plug when oil has drained.
  4. Remove oil dipstick and fill crankcase with recommended SAE 10W-30 oil.
  5. Do not overfill above the FULL mark.
  6. Install and tighten dipstick cap before operating engine.
Changing the Engine Oil and/or Oil Filter maintenance

⚠ DO NOT FILL ABOVE THE "FULL" MARK.

  1. Run the engine until thoroughly warmed up (at least five minutes) then shut OFF the engine.
  2. With the engine still warm, remove the oil drain plug and drain the oil into a suitable container.
  3. After the oil has drained, replace the oil drain plug.
  4. If changing the filter, remove the old oil filter by turning it counterclockwise.
  5. Apply a light coating of clean engine oil to the gasket of the new filter.
  6. Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter, then tighten an additional 3/4 to one turn.
  7. Remove the dipstick and fill crankcase with the proper type and amount of recommended oil (about 1.4 liters).
  8. Install and tighten the dipstick before operating the engine.
  9. Start the engine and check for leaks.
Changing the Oil Filter maintenance
  1. Turn oil filter counterclockwise to remove.
  2. Coat the gasket of the new filter with engine oil.
  3. Turn new filter clockwise until its gasket contacts the filter adapter.
  4. Tighten an additional 3/4 to one turn by hand.
  5. Run engine and check for leaks.
Checking Engine Oil Level maintenance

⚠ DO NOT OVERFILL ABOVE FULL MARK.

Tools: clean lint-free cloth

  1. Be sure generator is as level as possible.
  2. Remove oil dipstick and wipe dry with clean, lint-free cloth.
  3. Install and tighten oil dipstick, then remove again.
  4. Oil should be at dipstick FULL mark. Add oil to FULL mark only. Do not overfill.
  5. Install and tighten oil dipstick cap before operating engine.
Checking and Setting the Engine Spark Plug maintenance

⚠ Sparking can occur if the wire terminal does not fit firmly on the spark plug terminal end.

⚠ Do not blast the spark plug to clean.

Tools: Wire feeler gauge, Wire brush

  1. Clean the area around the base of the spark plug to keep dirt and debris out of the engine.
  2. Remove the spark plug and check the condition; replace if worn or if reuse is questionable.
  3. Check the spark plug gap using a wire feeler gauge.
  4. Adjust the gap to 0.030 inch (0.76 mm) by carefully bending the ground electrode.
Checking the Engine Oil Level maintenance

⚠ Never operate the engine with the oil level below the "Add" mark on the dipstick.

⚠ DO NOT FILL ABOVE THE "FULL" MARK.

  1. Be sure the generator is as level as possible.
  2. Remove the dipstick and wipe it dry with a clean, lint-free cloth.
  3. Install and tighten the dipstick cap; then remove it again. Oil level should be at the dipstick "Full" mark.
  4. If necessary, remove the oil fill cap on the rocker cover and slowly add oil until it reaches the "Full" mark.
  5. Install and tighten the oil fill cap and the dipstick before operating the engine.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
Grounding/bondingBonding conductor; No. 8 AWG copper wire minimumGround generator by solid mounting to vehicle frame/chassis or by approved bonding conductor. DO NOT disconnect bonding conductor. If replaced, use only flexible No. 8 AWG copper wire minimum.
1201Connection for 120 Volts Only (Figure 1)Dual stator power windings; grounded neutral; CB1These air-cooled Q Series generator sets are equipped with dual stator AC power windings supplying power by a dual 2-wire connection system.
1201Dual 2-wire connection system (120 volts only)Dual stator power windings; grounded neutralFigure 1 — Connection for 120 Volts Only; jumper between circuit breakers must be removed when connecting for 120/240 volts
120single120 volts only — dual 2-wire connection with jumper between circuit breakers installedFigure 1 connection for 120 volts only; grounded neutral
120 volts only1jumper installed between circuit breakersT1/T2/T3/T4, neutralstator dual 2-wire connection system
120/2401Reconnectable dual voltage outputDual stator power windingsAll units are reconnectable to 120 and/or 240 volts, dual voltage output; units are not listed per RVIA/ANSI when reconnected for dual voltage output
120/2401Reconnected for dual voltage AC outputDual stator power windingsBe sure to remove the jumper between the circuit breakers when connecting for 120/240 volts. If reconnected for dual voltage, the unit is no longer RVIA listed.
120/240singleDual voltage output — remove the jumper between the circuit breakersUnits are not listed per RVIA/ANSI when reconnected for dual voltage output; replacement line breakers consist of two separate breakers with a connecting piece between handles
230SingleDual two-wire connection system, neutral grounded (Figure 1.1 — Connections for 230 Volts Only)Dual stator AC power windings; two 30-amp circuit breakers. If reconnected for dual voltage AC output (115/230 volts), replacement line breakers consist of two separate breakers with a connecting piece between the handles.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the oil capacity of the Generac GN-570?

The Generac GN-570 engine has an oil capacity of 1.7 liters.

What is the displacement of the Generac GN-570?

The Generac GN-570 has a displacement of 0.57 liters.

Which generators use the Generac GN-570 engine?

The Generac GN-570 powers 2 generator set(s), including Generac Q-70G, Generac Q-70LP.

What is a common problem with the Generac GN-570 engine?

A commonly reported issue on generators using the Generac GN-570 is: The Start/Stop switch is set to Stop, but the engine continues to run.. Cause: 1. Defective Start/Stop switch 2. Open/Disconnected #18 wire between Start/Stop switch and engine control board 3. Open/Disconnected #0 wire betw. Fix: 1. Replace switch. 2. Reconnect or close wire. 3. Reconnect or close wire..