Procedure

  1. Check tag on engine for oil viscosity and classification; verify correct oil is used.
  2. Fill all battery cells to the proper level with distilled water.
  3. Do not use tap water in the battery.
  4. Recharge battery to 100% state of charge, or replace if defective.
  5. Turn off all electrical loads and add gasoline if necessary, then start the engine.
  6. Let the engine warm up.
  7. Apply electrical loads to at least 50% of the unit's rated wattage capacity.
  8. When the engine is thoroughly warmed up, shut it down.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Apply loads to at least 50% of rated wattage capacity

Full service-parts list: Generac 9592 →, Generac Q-55G →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.