Home›Repair guides›Generac›Servicing the Engine Air Cleaner

Generac — Servicing the Engine Air Cleaner

Maintenance

From a Generac owner's manual covering: 9592, GN-570, Q-55G, Q-70G. Check it applies to your exact model before use.

Applies to: Generac 9592, Generac Q-55G, Generac GN-480 engine, Generac GN-570 engine

Before you start

  • The new replacement paper filter must be a flame retardant type.

Parts for this job

Part numbers from the service-parts lists for Generac 9592, Generac Q-55G. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Turn KNOB counterclockwise to loosen.
  2. Remove cover, foam pre-cleaner and paper filter.
  3. Remove foam pre-cleaner from cover.
  4. Wash foam pre-cleaner in liquid detergent and water.
  5. Wrap foam pre-cleaner in a cloth and squeeze dry.
  6. Saturate foam pre-cleaner in engine oil; squeeze out excess oil.
  7. Install foam pre-cleaner into cover, followed by paper filter; tabs must lock into slots.
  8. Insert bottom locking tab of cover into slot; install cover, foam pre-cleaner and paper filter.

Specs & values

  • Clean and re-oil foam pre-cleaner every three months or every 25 hours, whichever occurs first
  • Replace paper filter once each year or every 100 operating hours, whichever comes first

Full service-parts list: Generac 9592 →, Generac Q-55G →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.