| 1100 | Overcrank | Engine Cranks but will not Start (5 crank attempts) | Shutdown | Problem 17 |
| 1200 | Overspeed | Prolonged over specified Hz for 3 seconds | Shutdown | Test 12 |
| 1205 | Overspeed | Instantaneous over specified Hz for 0.1 second | Shutdown | Test 12 |
| 1207 | Overspeed | Monitors zero cross timing of AVR; 150 ms of 4500 rpm or higher | Shutdown | Test 64 and Test 60 |
| 1300 | Low Oil Pressure | Occurred while running; check oil level and pressure | Shutdown | Test 61 |
| 1400 | High Temperature | Air flow impeded; check inlet/outlet for debris | Shutdown | Test 62 |
| 1501 | RPM Sensor | Twin Cylinder+Running; RPM sensor loss | Shutdown | Test 50 and Test 64 |
| 1505 | RPM Sensor | Twin Cylinder+Cranking; RPM sensor loss | Shutdown | If engine cranks, Test 64. If not crank, Problem 15. |
| 1511 | RPM Sensor | Single Cylinder+Running; RPM sensor loss | Shutdown | Test 50 and Test 64 |
| 1515 | RPM Sensor | Single Cylinder+Cranking; RPM sensor loss | Shutdown | If engine cranks, Test 64. If not crank, Problem 15. |
| 1600 | Underspeed | Unit is overloaded, slowing engine speed, fuel supply low or throttle control problem | Shutdown | Problem 3, or Test 50, or Test 12 |
| 1800 | Overvoltage | Prolonged over-voltage | Shutdown | |
| 1900 | Undervoltage | Prolonged under-voltage; below 80% for 10+ seconds | Shutdown | Preliminary Output Voltage Test |
| 1901 | Undervoltage | Instantaneous under-voltage due to sudden loss of voltage | Shutdown | Preliminary Output Voltage Test |
| 1902 | Undervoltage | Both zero crosses missing; faulty excitation winding or zero cross circuit | Shutdown | Preliminary Output Voltage Test |
| 1906 | Undervoltage | Single zero cross missing; faulty excitation winding or zero cross circuit | Shutdown | Preliminary Output Voltage Test |
| 2099 | Wiring Error | Mis-wired; customer connection low voltage and high voltage wires crossed | Shutdown | Check customer connection in generator |
| 2100 | Overload Remove Load | Overloaded - Default; one or both CTs detecting overload | Shutdown | Remove Load |
| 2299 | Undervoltage Overload | Unit was overloaded and attempted to start with large load | Shutdown | Remove Load |
| 2399 | Stepper Overcurrent | Current flow in stepper coil(s) above specification | Shutdown | Test 12 |
| 2400 | Fuse Problem | Missing or damaged 7.5 amp controller fuse | Shutdown | Test 44 |
| 2800 | Aux Shutdown | External shut down circuit is open | Shutdown | Check continuity of harness and operation of switch(es). Repair/replace as needed. |
| BATTERY PROBLEM | Battery Problem | Yellow LED illuminated | Warning | Contact servicing dealer. |
| CHARGER MISSING AC | Charger Missing AC | Battery charger missing AC input | Warning | |
| CHARGER WARNING | Charger Warning | Yellow LED illuminated | Warning | Contact servicing dealer. |
| EXERCISE SET ERROR | Exercise Set Error | Exercise timer setting error | Warning | |
| Exercise Set Error | Exercise Set Error | Warning; displayed if the exercise period becomes corrupted | Warning | Reset the exercise period to clear |
| FUEL PRESSURE | Fuel Pressure | Fuel pressure warning | Warning | |
| FUSE PROBLEM | Fuse Problem | Unit will not start in AUTO with utility loss | Warning | Check ATO 7.5 amp fuse. Replace with same type fuse if bad. Contact servicing dealer if fuse is good. |
| HIGH TEMPERATURE | High Temperature | Unit shuts down during operation | Shutdown | Check ventilation around the intake, exhaust and rear of generator. Contact servicing dealer if no obstruction is found. |
| High Engine Temperature | High Engine Temperature | Shutdown alarm, auto reset; 10 second delay on start-up and 1 second delay before shutdown; contacts close if temperature exceeds approximately 144 °C (293 °F) | Shutdown | Auto reset when condition clears and restart engine if a valid start signal is present |
| INSPECT BATTERY | Inspect Battery | Battery inspection reminder | Info | Inspect battery; press ENTER to clear. |
| INTERNAL FAULT | Internal Fault | Internal controller fault | Shutdown | Contact servicing dealer. |
| Internal Fault | Internal Fault | Shutdown alarm; this alarm cannot be cleared | Shutdown | Call service dealer |
| LOW BATTERY | Low Battery | Yellow LED illuminated | Warning | Clear alarm; check battery via control panel BATTERY MENU; if GOOD contact dealer, else replace battery |
| LOW OIL PRESSURE | Low Oil Pressure | Unit will not start in AUTO with utility loss | Shutdown | Check oil level. Add oil per Owner's Manual. Contact servicing dealer if oil level is correct. |
| LOW VOLTS REMOVE LOAD | Low Volts Remove Load | Unit will not start in AUTO with utility loss | Shutdown | Clear alarm and remove household loads, put back in AUTO and restart |
| Low Battery | Low Battery | Warning; battery voltage below 11.9 volts for one (1) minute; clears automatically if voltage rises above 12.4 volts; not monitored during crank cycle | Warning | Service or charge battery |
| Low Oil Pressure | Low Oil Pressure | Shutdown alarm; 5 second delay on start-up and 7 second delay once running; switch contacts close if oil pressure drops below the five (5) PSI range | Shutdown | Verify oil level; unit should not be restarted until oil level is verified |
| MISWIRE | Miswire | Unit will not start in AUTO with utility loss | Shutdown | Contact servicing dealer |
| Maintenance Message | Maintenance Message | Maintenance alert; displayed when a maintenance period expires | Info | Press Enter to confirm reset; clears the alert and resets maintenance counters |
| NOT ACTIVATED | Not Activated | Unit will not start in AUTO with utility loss | Warning | Refer to activation section in owners manual |
| OVER VOLTAGE | Over Voltage | Overvoltage alarm | Shutdown | Contact servicing dealer. |
| OVERCRANK | Overcrank | Unit will not start in AUTO with utility loss | Shutdown | Check fuel line shutoff valve is in the ON position. Clear alarm. Attempt to start in MANUAL. If it does not start or starts and runs rough, contact servicing dealer. |
| OVERLOAD REMOVE LOAD | Overload Remove Load | Unit shuts down during operation | Shutdown | Clear alarm, remove household loads, put back in AUTO and restart |
| OVERLOAD WARNING | Overload Warning | Overload warning | Warning | |
| OVERSPEED | Overspeed | Unit will not start in AUTO with utility loss | Shutdown | Contact servicing dealer. |
| OVERVOLTAGE | Overvoltage | Unit will not start in AUTO with utility loss | Shutdown | Contact servicing dealer |
| Over Crank | Over Crank | Shutdown alarm; occurs if the engine has not started within the specified crank cycle | Shutdown | Reset the control board and restart up to two more times if necessary |
| Over Speed | Over Speed | Shutdown alarm; 4320 RPM for three (3) seconds or 4500 RPM immediately | Shutdown | Contact the nearest Dealer if this failure occurs |
| Overvoltage | Overvoltage | Shutdown alarm; above 110% of rating for greater than three (3) seconds, or above 130% of rating for greater than 0.2 seconds | Shutdown | Check generator output |
| RPM SENSE LOSS | RPM Sense Loss | Unit was running and shuts down, attempts to restart | Shutdown | Clear alarm, remove household loads, put back in AUTO and restart; may be fuel issue, contact servicing dealer |
| RPM Sense Loss | RPM Sense Loss | Shutdown alarm; if no valid RPM signal within three (3) seconds during cranking, or lost for one (1) second while running | Shutdown | Control board shuts down, waits 15 seconds, then re-cranks; may re-crank once more before latching out |
| SERVICE A | Service Schedule A | Yellow LED illuminated, maintenance due | Info | Perform SERVICE A maintenance; press ENTER to clear. |
| SERVICE B | Service Schedule B | Yellow LED illuminated, maintenance due | Info | Perform SERVICE B maintenance; press ENTER to clear. |
| STEPPER OVER CURRENT | Stepper Over Current | Stepper motor over current | Shutdown | Contact servicing dealer. |
| STEPPER OVERCURRENT | Stepper Overcurrent | Unit will not start in AUTO with utility loss | Shutdown | Contact servicing dealer |
| UNDER VOLTAGE | Under Voltage | Undervoltage alarm | Shutdown | Contact servicing dealer. |
| UNDERSPEED | Underspeed | Unit will not start in AUTO with utility loss | Shutdown | Contact servicing dealer. |
| UNDERVOLTAGE | Undervoltage | Unit will not start in AUTO with utility loss | Shutdown | Contact servicing dealer |
| Under-frequency | Under-frequency | Shutdown alarm; if generator stays under frequency for more than 30 seconds; setting is 50 Hz | Shutdown | Check generator output |
| Undervoltage | Undervoltage | Shutdown alarm; if generator voltage falls below 60% of nominal for more than five (5) seconds | Shutdown | Check generator output and loads |
| WARNING | Low Battery | Battery less than 12.1 Volts for 60 seconds | Warning | Test 45 |
| WIRING ERROR | Wiring Error / Miswire | Controller wiring error | Shutdown | Contact servicing dealer. |