Procedure
- Open the evacuator valve weekly (or daily in dusty conditions).
- Wipe the inside air cleaner clean if dirty or wet.
- Blow compressed air from the inside, turning the element, at under 205 kPa (30 psi).
- For carbon/oil, soak element in detergent 15 minutes, wash several times, rinse, and dry naturally.
- Inspect the element with a light for damage after drying.
- Replace the primary element every year or every 6 cleanings; replace the secondary element at the same time.
Specs & values
- Air pressure not to exceed 205 kPa (2.1 kgf/cm2, 30 psi)
Full service-parts list: Kubota GL 11000 →, Kubota GL 7000 →, Kubota GL 9000 →, Kubota GL11000-STD →, Kubota GL11000-USA →, Kubota GL6000 →, Kubota GL6000-AUS →, Kubota GL6000-STD →, Kubota GL7000-STD →, Kubota Z482 engine →
Source: Kubota operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.