Procedure

  1. Open the evacuator valve weekly (or daily in dusty conditions).
  2. Wipe the inside air cleaner clean if dirty or wet.
  3. Blow compressed air from the inside, turning the element, at under 205 kPa (30 psi).
  4. For carbon/oil, soak element in detergent 15 minutes, wash several times, rinse, and dry naturally.
  5. Inspect the element with a light for damage after drying.
  6. Replace the primary element every year or every 6 cleanings; replace the secondary element at the same time.

Specs & values

  • Air pressure not to exceed 205 kPa (2.1 kgf/cm2, 30 psi)

Full service-parts list: Kubota GL 11000 →, Kubota GL 7000 →, Kubota GL 9000 →, Kubota GL11000-STD →, Kubota GL11000-USA →, Kubota GL6000 →, Kubota GL6000-AUS →, Kubota GL6000-STD →, Kubota GL7000-STD →, Kubota Z482 engine →

Source: Kubota operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.