Home›Kubota›Kubota GL11000-USA

Kubota GL11000-USA Generator Set

The Kubota GL11000-USA is a 11 kW Diesel standby generator set powered by a Kubota D722-E2B-SEC-2 engine. It is available at 120 V, single-phase, 60 Hz and rated 83.3 A. It holds about 3.4 L (0.9 gal) of oil and 4.1 L (1.1 gal) of coolant. Starting uses group-55 battery at 12 V. The set measures 1281×618×698 mm (50.4×24.3×27.5 in) and weighs about 280 kg (617 lb). An integrated tank holds 28 L (7.4 gal), roughly 7 hours of runtime.

11 kW
Standby
0.719 L
Displacement
3.4 L
Oil capacity
4
Document types

How to read your Kubota serial & model number →

Typical fuel consumption for 10–15 kW Diesel generators →

Compare with other 10–15 kW Diesel generators →

Service parts for the GL11000-USA

Grouped by system, with how many of each the parts manual calls for.

Fuel system

1 required
1522143081Fuel filter$37.58eBay

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power11 kW
EmissionsTier 2 / Phase 2
Oil capacity3.4 L
Voltage options120 V, 240 V
Phase1 - 3
Rated current83.3 A
Power factor1
Circuit breaker42 A
Battery group55B24R
Battery voltage12 V V
Coolant capacity4.1 L
Dimensions (L×W×H)1281×618×698 mm
Dry weight280 kg
Fuel tank28.0 L
Tank runtime7 hr

Engine

Kubota D722-E2B-SEC-2
Oil capacity3.4 L
Coolant capacity4.1 L
Displacement0.719 L
Rated speed3000 rpm

Maintenance & consumables

for the Kubota D722-E2B-SEC-2
ItemSpecCapacityPart #Interval
Air filterCheck/replace as required—160 hr
Fuel filterClean and screw in by hand; replace at 400 h / leak check after1522143081 Amazon eBay $37.58 KuduParts $13.00 FridayParts $15.69
Oil filter7665025430160 hr Amazon eBay $22.12 PartsGeek $7.98 NAPA $13.30
Battery—320 hr
BeltQuad Power XPZ 862—600 hr
CoolantGLYSANTIN PROTECT PLUS/G48; antifreeze content 40% to 60%4.1—320 hr
OilSAE 10W-30 / SAE 10W-40; API CC/CD/CF/CG3.8 l—160 hr
Spark plug—600 hr

Compatible filters for the Kubota D722-E2B-SEC-2 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

Service intervals

40
ItemActionHoursMonthsNotes
BatteryCheck100 hrFirst service — Initial 50 hours
Fuel line (fuel hose and clamp bands)Check50 hrEvery 50 hours
Fuel pipes and clamp bandsCheck50 hrFirst service — Replace fuel pipes and clamp bands every 2 years or earlier
Oil filter cartridgeChange200 hrFirst service — Initial 50 hours
Air cleaner elementClean100 hrFirst service — Every 100 hours
Battery electrolyteCheck100 hr
Engine oilChange100 hrFirst service — Initial change at first 50 hours, then every 100 hours
Fan beltCheck100 hrDamage, wear and tension
Fuel filterClean100 hrClean every 100 hours of operation
Fuel filter elementClean100 hrEvery 100 hours
Fuel filter potClean100 hr
Electric wiring and loose connectionsCheck200 hr
Fan belt tensionCheck200 hr
Oil filter cartridgeReplace200 hrFirst service — Replace earlier if necessary; after the initial 50 hours
Radiator hose and clamp bandsCheck200 hr6 moEvery 200 hours or every six months, whichever comes first
Radiator hoses and clamp bandsCheck200 hr6 moWhichever comes first
Generator's brush wareCheck300 hrEvery 300 hours
Generator's slip-ringCheck300 hrEvery 300 hours
Fuel filter cartridge or elementReplace400 hrFirst service
Fuel filter elementChange400 hrEvery 400 hours
Intake air hoseCheck400 hrFirst service
Fan beltReplace500 hr
RadiatorClean500 hrClean every 500 hours; also before adding anti-freeze and before stopping use of anti-freeze
Water jacket (radiator interior)Clean500 hrEvery 500 hours
BatteryReplace800 hr24 mo
Valve clearanceAdjust800 hrCheck and adjust when engine is cold
Valve clearanceCheck800 hrAdjust when engine is cold
Generator's ball bearingCheck1000 hrEvery 1000 hours
Electric wiringInspect1500 hrCheck for damage and loose connections
Fuel injection nozzle injection pressureCheck1500 hrConsult your local KUBOTA Dealer for this service
Fuel injection pressureCheck1500 hrEvery 1500 hours
Injection pumpCheck3000 hrConsult your local KUBOTA Dealer for this service
Nozzle spraying conditionCheck1500 hrEvery 1500 hours
Nozzle valve seat tightnessCheck1500 hrEvery 1500 hours
Air cleaner elementChange12 moOnce a year or every 6th cleaning
Air cleaner elementReplace1500 hr12 moReplace primary element every year or every 6 cleanings; replace secondary element at the same time
Air cleaner element (primary)Replace12 moEvery year or every 6 cleanings; replace secondary element at the same time
BatteryChange24 moEvery 2 years
Battery electrolyte levelCheck100 hr12 moYearly when used less than 100 hours/year (refillable battery)
Coolant (L.L.C)Change24 moKUBOTA genuine long-life coolant has a service life of 2 years

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir gap0.5mm
ClearanceAir gap0.8mm
ClearanceAir gap (rotor to stator)0.5mm
ClearanceAir gap (rotor to stator)0.7mm
ClearanceCrankshaft side clearance0.15 to 0.31mm
ClearanceCylinder head surface flatness allowable limit0.05mm
ClearanceCylinder liner I.D. (standard)67.000 to 67.019mm
ClearanceFan belt deflection12 to 14mmunder load of 98 N (22.1 lbs.), pressed in middle of span
ClearanceFan belt tension (deflection)12 to 14mm (0.47 to 0.55 in.)pressed in middle of the span under load of 98 N (22.1 lbs.)
ClearanceGenerator brush length (allowable limit)4.5mm
ClearanceGenerator brush length (allowable limit)7.5mm
ClearanceGenerator brush length (standard)15.0mm
ClearanceOil clearance between crankpin and crankpin bearing0.020 to 0.051mm
ClearancePiston ring gap, top ring0.15 to 0.30mm
ClearanceSlip ring outside diameter49.7mm
ClearanceSlip ring outside diameter64.0mm
ClearanceSlip-ring outside diameter49.7mmcorrection limit 47.5 mm
ClearanceSlip-ring outside diameter64.0mmcorrection limit 62.5 mm
ClearanceTop clearance0.50 to 0.70mm
ClearanceValve recessing (intake and exhaust)0.10 protrusion to 0.10 recessingmm
GapFan belt deflection7.0 to 9.0mmat 98 N (10 kgf, 22 lbf)
Injection timingInjection pump timing0.33 to 0.37 rad (19 to 21° before TDC)rad
Injection timingInjection timing0.30 to 0.33 rad (19 to 21° before TDC)rad
OtherAnti-freeze 50 vol% boiling point108°Cat 1.013 x 10^5 Pa (760 mmHg)
OtherAnti-freeze 50 vol% freezing point-37°C
OtherBattery charging rate (constant)6.0Ainitial battery charge
OtherBattery electrolyte specific gravity1.270 to 1.290at 20 degrees C (68 degrees F)
OtherBattery electrolyte specific gravity at charge completion1.27 to 1.29charge completed
OtherBattery electrolyte specific gravity when fully charged1.270 to 1.290at 20°C (68°F)
OtherBattery normal charging rate6.0A
OtherCompressed air pressure for cleaning air cleaner elementunder 205kPaat nozzle
OtherCoolant mixing ratio50/50%premix 50% LLC with 50% clean soft water
OtherFuel cetane number45 minimumgreater than 50 preferred below -20°C or above 1500 m
OtherGenerator power factor100%
OtherGlow plug continuous use limit20seconds
OtherPreheating time 10°C to -5°C (50°F to 23°F)Until glow lamp goes off
OtherPreheating time above 10°C (50°F)NO NEED
OtherPreheating time below -5°C (23°F)Approx. 5 seconds after the glow lamp goes offlimit of continuous use 20 seconds
OtherStarter motor continuous running limit10secondsif engine fails to start, wait about 30 seconds and try again
PressureCompressed air for air cleaner element cleaningunder 205kPaair pressure at nozzle
PressureCompression pressure2.84 to 3.24MPaat 3.3 to 5.0 1/s (200 to 300 rpm) with starter
PressureCompression pressure allowable limit2.26MPa
PressureEngine oil pressure at idle speedMore than 49kPaidle speed
PressureEngine oil pressure at rated speed196 to 441kParated speed
PressureEngine oil pressure drop warning lamp activation68.7 to 127.5kPa
PressureEngine oil pressure drop warning lamp set point68.7 to 127.5kPa (0.7 to 1.3 kgf/cm2)lamp flashes on below this oil pressure
PressureEngine oil pressure drop warning lamp threshold68.7 to 127.5kPaeasy checker lamp flashes on below this
PressureEngine oil pressure warning lamp threshold68.7 to 127.5kPalamp flashes on below this oil pressure
PressureFuel injection pressure13.73 to 14.71MPa
PressureFuel tightness of delivery valve10 secondss13.73 to 12.75 MPa (140 to 130 kgf/cm2)
PressureFuel tightness of delivery valve10 seconds (13.73 to 12.75 MPa)sfactory spec
PressureFuel tightness of pump element (allowable limit)13.7MPa
PressureFuel tightness of pump element (allowable limit)13.73MPa
PressureNozzle valve seat tightnessNo fuel leak at 12.75MPahold 10 seconds
PressureNozzle valve seat tightnessNo fuel leak at 12.75 MPa (130 kgf/cm2, 1849 psi)MPakept for 10 seconds
PressureOil pressure drop warning threshold68.7 to 127.5kPa (0.7 to 1.3 kgf/cm2)warning lamp flashes below this pressure
PressureRadiator cap pressure falling time10 seconds or more (88 to 59 kPa)s
PressureRadiator cap pressure falling timeMore than 10 secondss88 to 59 kPa (0.9 to 0.6 kgf/cm2, 13 to 9 psi)
PressureRadiator water leakage test pressure157kPa
ResistanceGlow plug resistanceApprox. 0.9ohm

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 ethylene glycol long-life coolant (LLC) and clean soft waterSAE J1034 / SAE J814c3.7 LKubota genuine LLC has 2-year service life
Coolant50/50 mix of long-life coolant (ethylene glycol type) and clean soft waterSAE J1034 / SAE J814c3.7 LIncluding reserve tank 0.6 L; change every 2 years; flush radiator with fresh water before use
CoolantClean water (soft water) with antifreeze 50/50Permanent type (PT) antifreeze; refer to SAE J1034 / SAE J814c; 40 vol% freezing point -24 °C, 50 vol% -37 °C3.7 LAntifreeze mixing ratio must be less than 50 %
CoolantClean water (soft water), antifreeze 50/503.7 LGL6000, GL7000; anti-freeze mixing ratio less than 50 %
CoolantEthylene glycol (EG) type long-life coolant, 50/50 mix with clean soft waterSAE J1034; SAE J814c3.7 LGL6000/GL7000 (Z482); 3.7 L (3.9 U.S.qts.), include reserve tank 0.6 L (0.63 U.S.qts.); change every 2 years
CoolantLong-life coolant (LLC), ethylene glycol type, 50/50 with clean soft waterSAE J1034 / SAE J814c3.7 LGL6000, GL7000 (Z482); change every 2 years; includes reserve tank 0.6 L; GL9000/GL11000 (D722) = 4.1 L
Engine oilAPI classification CF, CF-4, CG-4, CH-4 or CI-4 with ultra low sulfur fuel; CF with high sulfur fuel2.2 LGL6000/GL7000 (engine Z482); 2.2 L (2.3 U.S.qts.)
Engine oilAPI service class CF or higherMIL-L-2104C2.2 LChange oil type according to ambient temperature
Engine oilCFHigh Sulfur Fuel [>0.05% (500 ppm)]Other than North American market; halve intervals if CF-4/CG-4/CH-4/CI-4 used with high-sulfur fuel
Engine oilCF, CF-4, CG-4, CH-4 or CI-4Ultra Low Sulfur Fuel [<0.0015% (15 ppm)]North American market; CJ-4 intended for DPF type engines
Engine oilCF-4, CG-4, CH-4 or CI-4Low Sulfur Fuel [<0.05% (500 ppm)] or Ultra Low Sulfur Fuel [<0.0015% (15 ppm)]Other than North American market
Engine oilSAE 10W-30 or 10W-40API service class CF or higher (MIL-L-2104C)below -10°Cbelow -10°C (14°F); oil viscosity higher than 10W-30 not allowed
Engine oilSAE10W or SAE10W-30/10W-40API CD or higherbelow 0°CBelow 0°C (32°F)
Engine oilSAE10W-30below -10°CBelow -10 degrees C (14 degrees F)
Engine oilSAE10W-30, SAE10W-40, SAE10Higher than CD class (API)below 0°CBelow 0 °C (32 °F)
Engine oilSAE10W-30, SAE30 (above 25 °C); SAE10W-30, SAE10W-40, SAE20 (0 to 25 °C); SAE10W-30, SAE10W-40, SAE10 (below 0 °C)API classification higher than CF; CF, CF-4, CG-4, CH-4 or CI-4 for low/ultra low sulfur fuel; CF or CI-4 for internal/external EGR engines2.2 LMinimum TBN of 10 recommended with high sulfur fuel; change oil at approximately half intervals with high-sulfur fuel
Engine oilSAE10W-30 or SAE15W-40-10°C to 25°C-10 to 25 degrees C (14 to 77 degrees F)
Engine oilSAE10W-30, SAE10W-40, SAE20Higher than CD class (API)0°C to 25°C0 to 25 °C (32 to 77 °F)
Engine oilSAE20 or SAE10W-30/10W-40API CD or higher0°C to 25°C0 to 25°C (32 to 77°F)
Engine oilSAE 10W-30 or 10W-40 or 15W-40API service class CF or higher (MIL-L-2104C)above 25°Cabove 25°C (77°F)
Engine oilSAE10W-30, SAE30Higher than CD class (API)above 25°CAbove 25 °C (77 °F)
Engine oilSAE30 or SAE10W-30 or SAE15W-40API classification CF or higher; MIL-L-2104Cabove 25°CAbove 25°C (77°F)
Engine oilSAE30 or SAE10W-30, SAE15W-40above 25°CAbove 25 degrees C (77 degrees F)
Engine oilSAE30 or SAE10W-30/10W-40API CD or higherabove 25°CAbove 25°C (77°F)
Engine oilSAE30 or SAE10W-30; SAE15W-40API classification CF or higher; MIL-L-2104Cabove 25°CAbove 25°C (77°F)
FuelDiesel fuel No.2-DASTM D975; EN 590Cetane number 45 minimum (>50 preferred below -20°C or above 1500 m); below 0°C a mix of No.1-D and No.2-D is acceptable; No.2-D S15 in EPA regulated area
FuelDiesel fuel No.2-D (ASTM D975)ASTM D975; EN 590; cetane number 45 minimum (greater than 50 preferred)Below 0°C (32°F) a mix of No.1-D and No.2-D is acceptable; in EPA regulated areas use No.2-D S15 or No.1-D S15 below -10°C (14°F)
FuelDiesel fuel No.2-D (ASTM D975), cetane number 45 minimumASTM D975 / EN 59028.0 L (7.4 U.S.gal.)Below 0°C (32°F) mix No.1-D and No.2-D; ultra low sulfur fuel mandatory in EPA-regulated area
FuelDiesel fuel No.2-D (No.1-D/No.2-D mix below 0 degrees C)ASTM D975 / EN 59028.0 LCetane number 45 minimum; use No.2-D S15 or No.1-D S15 in EPA regulated areas; never use gasoline or alcohol
FuelDiesel fuel; minimum cetane rating 45 (greater than 50 preferred)EN 590 or ASTM D975 recommended; No.2-D (SAE J313 JUN87); use No.2-D S500 or S15 in US EPA regulated areas28.0 LSulfur content less than 0.10 % (1000 ppm) strongly recommended; do not use fuels with sulfur content greater than 1.0 % (10000 ppm)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting Fan Belt Tension adjustment

⚠ Be sure to stop the engine and remove the key before checking the belt tension.

⚠ Be sure to reinstall the detached safety shield after maintenance or checking.

  1. Stop the engine and remove the key.
  2. Apply moderate thumb pressure to belt between pulleys.
  3. If tension is not as specified, loosen the lock nut and turn the adjust nut to get belt tension within range.
  4. Tighten up the lock nut.
  5. Replace fan belt if it is damaged.
Adjusting Valve Clearance adjustment

⚠ Valve clearance must be checked and adjusted when engine is cold.

Tools: Feeler gauge

  1. Remove the head cover, the glow plugs and the timing window cover.
  2. Align the 1TC mark line on the flywheel with center of timing window for No. 1 piston.
  3. Check valve clearance with a feeler gauge.
  4. Adjust with the adjusting screw if not within factory specification.
  5. Turn flywheel 6.28 rad (360°) and adjust all other valve clearances.
  6. Recheck clearance and firmly tighten the lock nut.
Checking Fan Belt Tension adjustment

Tools: Belt tension gauge

  1. Measure the deflection by depressing the belt halfway between the fan drive pulley and alternator pulley.
  2. Loosen the alternator mounting screws if not within specification.
  3. Relocate the alternator to adjust.
Checking and Adjusting Valve Clearance adjustment

⚠ Valve clearance must be checked and adjusted when engine is cold.

Tools: Feeler gauge

  1. Remove head cover, glow plugs and timing window cover on flywheel housing.
  2. Align 1TC mark line on flywheel with center of timing window for No.1 TDC.
  3. Check valve clearance with a feeler gauge.
  4. If out of specification, adjust with adjusting screw.
Checking Fuel Injection Pressure diagnostic

⚠ Check after making sure nobody stands in the direction the fume goes.

Tools: Nozzle tester

  1. Set the injection nozzle to a nozzle tester.
  2. Slowly move the tester handle to measure pressure at which fuel begins jetting out.
  3. Replace the adjusting washer in the nozzle holder to adjust if out of specification.
Connecting the load (terminal output model) installation

⚠ Connect or disconnect load only when engine is stopped

  1. Turn OFF the circuit breaker on the control panel.
  2. Connect the load to the A.C. output terminals.
  3. Close the terminal cover after connecting the load.
  4. Secure the cover with the lock bolts.
Air bleeding the fuel system maintenance

⚠ Do not bleed a hot engine as this could cause fuel to spill onto a hot exhaust manifold creating a danger of fire.

  1. Fill the fuel tank to the fullest extent. Open the fuel filter cock.
  2. Loosen air vent plug of the fuel filter a few turns.
  3. Screw back the plug when bubbles do not come up any more.
  4. Open the air vent plug on top of the fuel injection pump.
  5. Retighten the plug when bubbles do not come up any more.
Battery charging maintenance

⚠ The batteries come in two types: refillable and non-refillable. Do not use or charge a refillable battery if the fluid level is below the LOWER mark.

Tools: Charger, Voltmeter or hydrometer

  1. Make sure each electrolyte level is to the bottom of vent wells; add only distilled water if necessary.
  2. To slow charge, connect the charger positive terminal to the battery positive terminal and the negative to the negative.
  3. Recharge the battery as early as possible, or battery life will be extremely shortened.
  4. When exchanging an old battery for a new one, use a battery of equal specifications.
Changing Battery maintenance

⚠ Stop engine before disconnecting cables; disconnect negative first, connect positive first.

  1. Open the generator door.
  2. Disconnect the cable from battery negative terminal.
  3. Disconnect the cable from battery positive terminal.
  4. Remove the battery.
  5. Install the new battery.
Changing Coolant maintenance

⚠ DO NOT remove the radiator cap while coolant is hot.

⚠ Work only after letting the engine and radiator cool off completely (more than 30 minutes after stopped).

  1. To drain coolant, always remove both drain plugs and simultaneously open the radiator cap.
  2. Remove the overflow pipe of the radiator pressure cap to drain the reserve tank.
  3. Prescribed coolant volume includes reserve tank 0.6 L (0.63 U.S.qts.).
  4. Fill with clean, fresh water and 50% anti-freeze.
Changing Coolant (L.L.C.) maintenance

⚠ Do not remove the radiator cap when the engine is hot.

  1. Stop the engine and let cool down.
  2. Open the water drain plug and remove radiator cap to drain the coolant.
  3. Close the water drain plug.
  4. Fill with clean water and anti-freeze until coolant level is just below the port.
  5. Fill with coolant up to FULL mark on the recovery tank.
  6. Start and operate the engine for few minutes, stop and let cool.
  7. Check coolant level of recovery tank and add coolant if necessary.
Changing Engine Oil maintenance

⚠ Be sure to stop the engine before draining engine oil.

⚠ DO NOT drain oil from a hot engine. Allow engine to cool down sufficiently to avoid being burned.

  1. Change oil after the initial 50 hours of operation and every 100 hours thereafter.
  2. Remove the drain plug to drain the engine oil; drain completely while warm.
  3. Inspect drain plug gasket. Replace if damaged.
  4. Install the oil drain plug and gasket.
  5. Add new engine oil up to the upper line of the oil level gauge.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
110 / 220 V1 - 4GL7000-STD, 60 HzMain coil R - W 0.25 ohm; BR - L 0.25 ohmNFB capacity 29.5 A
110/2201Main coilR - W; BR - LGL7000-STD; 0.25 Ω each
110/2201Single phase 3 terminals type (1P4W type) dual voltageGL7000-STD, 60 Hz
120 / 240 V1 - 3GL11000-USA, GL11000-USA-TM, 60 HzMain coil 1 - 3: 0.23 ohm; 1 - 2 and 2 - 3: 0.12 ohm; sub coil LG - LG 1.68 ohm; rotor coil 55.5 ohmNFB capacity 42 A; GL11000-STD (110/220 V) main coil 0.19 / 0.10 / 0.10 ohm, sub coil 1.73 ohm, NFB 45.5 A
120 / 240 V1 - 4GL7000-USA, GL7000-USA-TM, 60 HzMain coil R - W 0.28 ohm; BR - L 0.28 ohmNFB capacity 27.5 A
120/2401Main coilR - W; BR - LGL7000-USA; 0.28 Ω each
120/2401Receptacle outputGL7000-USA, GL11000-USA, 60 Hz
120/2401Single phase 3 terminals type (1P4W type) dual voltageGL7000-USA-TM, 60 Hz
2201Main coilR - WGL6000-STD; 0.55 Ω
2201Single phase 2 terminals typeGL6000-STD, GL9000-STD, 50 Hz
220 V1 - 2GL6000-STD, 50 HzMain coil R - W: 0.55 ohmSub coil G - LG/R 1.08 ohm; sub coil (DC) L/W - L/W 0.11 ohm; detecting coil LG - L 0.05 ohm; rotor coil 59.5 ohm
220 V1 - 3GL9000-STD, 50 HzMain coil 1 - 3: 0.28 ohm; sub coil LG - LG 1.96 ohm; detecting coil R - R 0.04 ohm; rotor coil 55.5 ohmNFB capacity 36.5 A; 240 V (GL9000-AUS) 0.34 ohm, NFB 33.5 A
2401Main coilR - WGL6000-AUS; 0.62 Ω
2401Receptacle outputGL6000-AUS, GL9000-AUS, 50 Hz
240 V1 - 2GL6000-AUS, 50 HzMain coil R - W: 0.62 ohmNFB capacity 23 A

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the Kubota GL11000-USA?

The Kubota GL11000-USA is rated 11 kW standby.

What engine is in the Kubota GL11000-USA?

The Kubota GL11000-USA is powered by the Kubota D722-E2B-SEC-2 engine.

Is the Kubota GL11000-USA diesel or gas?

The Kubota GL11000-USA runs on Diesel.

What's the oil capacity on a Kubota GL11000-USA?

The Kubota D722-E2B-SEC-2 engine in the Kubota GL11000-USA has an oil capacity of 3.4 liters.

What is the coolant capacity of the Kubota GL11000-USA?

The Kubota GL11000-USA cooling system holds 4.1 liters (1.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

How much does the Kubota GL11000-USA weigh?

The Kubota GL11000-USA has a dry weight of 280 kg (617 lb).

How big is the fuel tank on the Kubota GL11000-USA?

The Kubota GL11000-USA has a 28 liter (7 US gallon) fuel tank, giving about 7 hours of runtime.

What voltages is the Kubota GL11000-USA available in?

The Kubota GL11000-USA is offered in 120 V, 240 V, 1 - 3-phase.

What oil filter fits the Kubota GL11000-USA?

The Kubota GL11000-USA uses oil filter part number 7665025430.

Which fuel filter part number does the Kubota GL11000-USA take?

The Kubota GL11000-USA uses fuel filter part number 1522143081.

Which air filter part number does the Kubota GL11000-USA take?

The Kubota GL11000-USA uses air filter part numbers KUBOTA 1522211223, KUBOTA RG64842831.

Troubleshooting

27

Symptoms & remedies

SymptomCauseRemedy
After electrical equipment connected, generator does not operate.Circuit breaker is off.Turn breaker "ON".
After electrical equipment connected, generator does not operate.Contact of output terminal and socket is bad.Reinstall.
After electrical equipment connected, generator does not operate.Malfunction of electrical equipmentRequest repair.
Not generatingBad contact of brushCheck, cleaning and maintenance of contact face and contact force of brush and slip ring. (Danger: All works should be performed when stopped)
Circuit breaker can not be operated.OverloadReduce load.
Circuit breaker can not be operated.Short circuit of load circuitry connected to output sectionRepair load.
Output cannot be obtained. — Rotation goes slow. Voltage drops. Breaker turns off.Initial current is too much. (e.g. motor load)Reduce load.
Output cannot be obtained. — Rotation goes slow. Voltage drops. Breaker turns off.OverloadReduce load.
Engine indicates loaded condition.Short circuit of generator wiringStop immediately. Request for repair.
When the key is turned, the lamp doesn't light on.Bulb is defective.Replace
When the key is turned, the lamp doesn't light on.Component or wiring defect of charging circuitCheck, repair
The water temperature lamp lights on when operating.Engine overheating.See "Precaution overheating" in "Radiator" section. (See page 97)
The water temperature lamp lights on when operating.Water temperature sensor faulty.Replace the water temperature sensor.
The water temperature lamp lights on when operating.Water temperature sensor wiring faulty.Repair the wiring.
The oil pressure lamp lights on when operating.Insufficient engine oil.Add engine oil.
The oil pressure lamp lights on when operating.Lubricating system in trouble.Check the system.
The oil pressure lamp lights on when operating.Oil pressure sensor faulty.Replace the sensor.
The oil pressure lamp lights on when operating.Oil pressure sensor wiring faulty.Repair the wiring.
The battery charge lamp lights on when operating.Poor contact of sub winding.Connect tightly.
The battery charge lamp lights on when operating.Sub winding problem.Check the sub winding.
Not started. — Not turned or slow turning.Battery trouble.Replacement of battery.
Not started. — Not turned or slow turning.Insufficient battery charge.Recharge battery.
Not started. — Not turned or slow turning.Slow turning at cold circumstance due to high viscosity of engine oil.Replace engine oil to D5W40 or D10W30 for cold.
Not started. — Not turned or slow turning.Fuse blown out (Slow blow fuse)Replace fuse.
Not started. — Not turned or slow turning.Terminal cover open.Close terminal cover. Fix terminal cover with panel lock bolts.
Not started. — Normal turning, but not started.Fuel shortage.Refuel.
Battery fluid level stands below the LOWER mark.Immediately, add distilled water until the fluid level is between the UPPER and LOWER levels. (for only refillable battery)

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

59
Part #DescriptionQtySystem
07909-30241PlastigagePlastigage Amazon eBay
07909-31371Red CheckRed check Amazon eBay
07909-31661Connecting Rod Alignment ToolConnecting rod alignment tool Amazon eBay
07909-33102Valve Seat CutterValve seat cutter Amazon eBay
07916-09032Special Use Puller SetSpecial use puller set Amazon eBay
07916-32011Flywheel PullerFlywheel puller Amazon eBay
07916-32032Oil Pressure TesterOil pressure tester Amazon eBay
07916-34041Auxilary Socket for Fixing Crankshaft SleeveAuxiliary socket for fixing crankshaft sleeve Amazon eBay
1T021-43560Fuel FilterFuel filter Amazon eBay $9.25 KuduParts $8.00 FridayParts $8.19
32721-58242Air Filter InnerAir filter Amazon eBay $34.95 KuduParts $13.00 FridayParts $15.50 SinoCMP $69.00
412-035-00Air Filter1Air filter Amazon eBay
412-036-00Oil Filter1Oil filter Amazon eBay
412-037-00Fuel Filter1Fuel filter Amazon eBay
412-038-00Coolant Filter1Coolant filter Amazon eBay
412-039-00Belt1Belt Amazon eBay
412-040-00Battery1Battery Amazon eBay
412-041-00Spark Plug1Spark plug Amazon eBay
6C060-99410Air Filter OuterAir filter Amazon eBay $37.24 KuduParts $21.00 FridayParts $22.74 SinoCMP $69.00
FP1-000410Impellerpumpe F4B-91Pump Amazon eBay
FP1-000421Luftfiltereinsatz 100x60x15mm grob Typ 11Hydraulic filter Amazon eBay
FP1-000434Ölfilter für Kubota Typ Z482, D722, D782, V8001Hydraulic filter Amazon eBay
FP1-000446Entlüftungsadapter Motorwasserpumpe Kubota Motoren H=37mm1Pump Amazon eBay
FP1-000449Oberteil für Thermostatgehäuse mit Entlüftung1Thermostat Amazon eBay
FP1-000582Dichtung Wasserpumpe Z482/D722/V8001Pump Amazon eBay
FP1-000589Dichtung Thermostatgehäuse1Thermostat Amazon eBay
FP1-000597Wasserpumpe Kubota Z 482 / D7221Pump Amazon eBay
FP1-000604Thermostatgehäuse Unterteil Z4821Thermostat Amazon eBay
FP1-000637Kühlwasserschlauch Wasserpumpe Z482 D7221Pump Amazon eBay
FP1-000766Halterung Impellerpumpe F4B-91Pump Amazon eBay
FP1-001724Impellersatz für Pumpe F4B mit O-Ring und Dichtung1Pump Amazon eBay
FP2-000370Halterung für Kraftstofffilter Typ 025-RAC1Hydraulic filter Amazon eBay
FP2-000371Sammelbehälter für Kraftstofffilter Typ 025-RAC durchsichtig1Hydraulic filter Amazon eBay
FP2-000373Kraftstofffiltereinsatz Typ 025-RAC 10 micron inklusive O-Ring1Hydraulic filter Amazon eBay
FP2-003434Halter Kraftstofffilter für D7221Hydraulic filter Amazon eBay
FP2-006951Halterung Luftfiltereinsatz 63x63mm1Hydraulic filter Amazon eBay
G3102-10011Rotor Pulling Out Bolt (for GL6000, GL7000)Rotor pulling out bolt Amazon eBay
G3102-8830-0Gasket1Gasket Amazon eBay
G3102-8831-0Coolant filter1Coolant filter Amazon eBay
G3102-8832-0V-belt1Belt Amazon eBay
G3102-8833-0Battery1Battery Amazon eBay
G3102-8836-0Spark plug1Spark plug Amazon eBay
G3102-8838-0Fuel filter1Fuel filter Amazon eBay
G3102-8839-0Air cleaner1Air filter Amazon eBay
G3102-8841-0Oil filter cartridge1Oil filter Amazon eBay
GL9000Fuel filter cartridge or elementFuel filter Amazon eBay FridayParts $15.80
HH150-32094OIL FILTEROil filter Amazon eBay $19.99 NAPA $9.64 KuduParts $17.00 FridayParts $18.90
HH150-32430OIL FILTEROil filter Amazon Amazon eBay $39.49 eBay $17.99 NAPA $9.64 KuduParts $11.00 FridayParts $13.16
P02-004Air filter1Air filter Amazon eBay
P02-005Oil filter1Oil filter Amazon eBay
P02-006Fuel filter1Fuel filter Amazon eBay
P02-007Belt1Belt Amazon eBay
P02-008Belt1Belt Amazon eBay
P02-009Battery1Battery Amazon eBay
P02-010Spark plug1Spark plug Amazon eBay
W10252400Injection Pump Pressure TesterInjection pump pressure tester Amazon eBay
W1040289Idle Gear Bushing Replacing ToolIdle gear bushing replacing tool Amazon eBay
W1062553Connecting Rod Small End Bushing ToolConnecting rod small end bushing tool Amazon eBay
1535981TRACK A 304/305Service part / kit Amazon eBay
W1046346Brush length (Stretch out of the Holder)1Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Continuous100%2.40.63

Available documents

Operator's manual — 59890 (Kubota)Operator's manual — Kubota-GL9000-Operators-Manual (Kubota)Reference — FAQ KTC-Dealers-2025-2 (Kubota)Owner's manual — 2950 gl7000 operatorsm (Kubota)Owner's manual — 635adac789d0116565862577 Kubota GL11000 Operators Manual (Kubota)Owner's manual — GEN 1 PH 6 KVA D Kubota GL 6000 GL 6000 D Operation Manual pdf 3421faafee (Kubota)Owner's manual — GL-Series-GL-7000-GL11000-Operators-Manual (Kubota)Owner's manual — Kubota LowBoy II Diesel Generator GL7000 GL11000 GL Series - Operators Manual (Kubota)Service manual — 635adac789d0113e87862586 Kubota GL-Series Service Manual (Kubota)Service manual — Kubota LowBoy II Diesel Generator GL7000 GL11000 GL Series - Service Manual (Kubota)

This page was generated from the 10 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Fuel filter 1522143081$37.58
Oil filter 7665025430$7.98
2 priced items$45.56