Home›Kubota›Kubota GL 11000

Kubota GL 11000 Generator Set

The Kubota GL 11000 is a 12.2 kW Diesel standby generator set powered by a Kubota D722 engine. It is available at 110/220 V and 120/240 V, single-phase, 60 Hz and rated 83.3 A. It holds about 3.4 L (0.9 gal) of oil and 4.1 L (1.1 gal) of coolant. Starting uses 1 group-55 battery at 12 V. The set measures 1281×618×698 mm (50.4×24.3×27.5 in), weighs about 295 kg (650 lb) and produces 68 dBA at 7 m. An integrated tank holds 28 L (7.4 gal), roughly 7 hours of runtime. The same D722 engine also powers generator sets from Atlas Copco, FG Wilson, Fischer Panda and WhisperPower.

12 kW
Standby
0.719 L
Displacement
3.4 L
Oil capacity
4
Document types

How to read your Kubota serial & model number →

Typical fuel consumption for 10–15 kW Diesel generators →

Compare with other 10–15 kW Diesel generators →

Service parts for the GL 11000

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Fuel system

1 required

Oil system

1 required

Belts

1 required

Cooling system

1 required

Electrical

1 required

Ignition

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power12 kW
Prime power12 kW
EmissionsEPA Tier 4 Final
Oil capacity3.4 L
Voltage options110/220 V, 120/240 V
Phase1
Rated current83.3 A
Power factor100
Battery group55B24R
Battery voltage12 V
Battery quantity1
Coolant capacity4.1 L
Dimensions (L×W×H)1281×618×698 mm
Dry weight295 kg
Sound level68.0 dBA @ 7 m
Fuel tank28.0 L
Tank runtime7.0 hr

Engine

Kubota D722
Oil capacity3.4 L
Coolant capacity4.1 L
Displacement0.719 L
AspirationTurbocharged
Rated speed3000 rpm

Filters for the Kubota D722

4

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP550227Lube Filter, Spin-On Full FlowKUBOTA 1521332430, KUBOTA 6602136060, LPM 00013505345, WALGAHN-MOTORENTECHN 00811292 KuduParts $18.00 FridayParts $20.25
Oil filterP550726Lube Filter, Spin-On Full FlowKUBOTA 1584132431, KUBOTA HH15232432, NAPA 61334, BALDWIN B227 FridayParts $12.70
Fuel filterP550012Fuel Filter, In-LineKUBOTA 1258143010, KUBOTA 1258143011, BALDWIN BF840-K1, RENAULT VI 0005490862 KuduParts $13.00 FridayParts $15.50
Fuel / water separatorP551039Fuel Filter, Water Separator Spin-On Twist&DrainNAPA 3192, BALDWIN BF1257, CLUB CAR 102614001, CLUB CAR 102703401 FridayParts $25.40 KuduParts $97.00

Same engine, other brands

4 brands

The Kubota D722 in this set also powers 7 generator sets sold under 4 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
WhisperPowerPiccolo 10, Piccolo 12, Piccolo GV 3
Atlas CopcoXAS 38, XAS 38 Kd
FG WilsonKH9-1S
Fischer PandaMini-Power Station

Maintenance & consumables

for the Kubota D722
ItemSpecCapacityPart #Interval
Air filterClean every year or every 6 cleanings, replace sooner if heavily stainedG3102-8839-0200 hr Amazon eBay
Fuel filterClean every 100 hours or as neededG3102-8838-0500 hr Amazon eBay
Oil filterReplace every 200 hours of operationG3102-8841-0500 hr Amazon eBay
BatteryCheck electrolyte level yearly for batteries used less than 100 hours in a yearG3102-8833-0500 hr Amazon eBay
BeltCheck every 50 hours of operation, replace if necessaryG3102-8832-01000 hr Amazon eBay
CoolantChange as needed based on operating conditions—500 hr
Coolant filterChanging Coolant, Remedies for Rapid Coolant LossG3102-8831-0200 hr Amazon eBay
Oil50.0 L—500 hr
Spark plugReplace as needed based on operating conditionsG3102-8836-0 Amazon eBay

Service intervals

40
ItemActionHoursMonthsNotes
BatteryCheck100 hrFirst service — Initial 50 hours
Fuel line (fuel hose and clamp bands)Check50 hrEvery 50 hours
Fuel pipes and clamp bandsCheck50 hrFirst service — Replace fuel pipes and clamp bands every 2 years or earlier
Oil filter cartridgeChange200 hrFirst service — Initial 50 hours
Air cleaner elementClean100 hrFirst service — Every 100 hours
Battery electrolyteCheck100 hr
Engine oilChange100 hrFirst service — thereafter
Fan beltCheck100 hrDamage, wear and tension
Fuel filterClean100 hrClean every 100 hours of operation
Fuel filter elementClean100 hrEvery 100 hours
Fuel filter potClean100 hr
Electric wiring and loose connectionsCheck200 hr
Fan belt tensionCheck200 hr
Oil filter cartridgeReplace200 hrFirst service — Replace earlier if necessary; after the initial 50 hours
Radiator hose and clamp bandsCheck200 hr6 moEvery 200 hours or every six months, whichever comes first
Radiator hoses and clamp bandsCheck200 hr6 mowhichever comes first
Generator's brush wareCheck300 hrEvery 300 hours
Generator's slip-ringCheck300 hrEvery 300 hours
Fuel filter cartridge or elementReplace400 hrFirst service
Fuel filter elementChange400 hrEvery 400 hours
Intake air hoseCheck400 hrFirst service
Fan beltReplace500 hr
RadiatorClean500 hrClean every 500 hours; also before adding anti-freeze and before stopping use of anti-freeze
Water jacket (radiator interior)Clean500 hrEvery 500 hours
BatteryReplace800 hr24 mo
Valve clearanceAdjust800 hrCheck and adjust when engine is cold
Valve clearanceCheck800 hrAdjust when engine is cold
Generator's ball bearingCheck1000 hrEvery 1000 hours
Electric wiringInspect1500 hrCheck for damage and loose connections
Fuel injection nozzle injection pressureCheck1500 hrConsult your local KUBOTA Dealer for this service
Fuel injection pressureCheck1500 hrEvery 1500 hours
Injection pumpCheck3000 hrConsult your local KUBOTA Dealer for this service
Nozzle spraying conditionCheck1500 hrEvery 1500 hours
Nozzle valve seat tightnessCheck1500 hrEvery 1500 hours
Air cleaner elementChange12 moOnce a year or every 6th cleaning
Air cleaner elementReplace1500 hr12 moReplace primary element every year or every 6 cleanings; replace secondary element at the same time
Air cleaner element (primary)Replace12 moEvery year or every 6 cleanings; replace secondary element at the same time
BatteryChange24 moEvery 2 years
Battery electrolyte levelCheck100 hr12 moYearly when used less than 100 hours/year (refillable battery)
Coolant (L.L.C)Change24 moKUBOTA genuine long-life coolant has a service life of 2 years

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir gap0.5mm
ClearanceAir gap0.8mm
ClearanceAir gap (rotor to stator)0.5mm
ClearanceAir gap (rotor to stator)0.7mm
ClearanceCrankshaft side clearance0.15 to 0.31mm
ClearanceCylinder head surface flatness allowable limit0.05mm
ClearanceCylinder liner I.D. (standard)67.000 to 67.019mm
ClearanceFan belt deflection12 to 14mmunder load of 98 N (22.1 lbs.), pressed in middle of span
ClearanceFan belt tension (deflection)12 to 14mm (0.47 to 0.55 in.)pressed in middle of the span under load of 98 N (22.1 lbs.)
ClearanceGenerator brush length (allowable limit)4.5mm
ClearanceGenerator brush length (allowable limit)7.5mm
ClearanceGenerator brush length (standard)15.0mm
ClearanceOil clearance between crankpin and crankpin bearing0.020 to 0.051mm
ClearancePiston ring gap, top ring0.15 to 0.30mm
ClearanceSlip ring outside diameter49.7mm
ClearanceSlip ring outside diameter64.0mm
ClearanceSlip-ring outside diameter49.7mmcorrection limit 47.5 mm
ClearanceSlip-ring outside diameter64.0mmcorrection limit 62.5 mm
ClearanceTop clearance0.50 to 0.70mm
ClearanceValve recessing (intake and exhaust)0.10 protrusion to 0.10 recessingmm
GapFan belt deflection7.0 to 9.0mmat 98 N (10 kgf, 22 lbf)
Injection timingInjection pump timing0.33 to 0.37 rad (19 to 21° before TDC)rad
Injection timingInjection timing0.30 to 0.33 rad (19 to 21° before TDC)rad
OtherAnti-freeze 50 vol% boiling point108°Cat 1.013 x 10^5 Pa (760 mmHg)
OtherAnti-freeze 50 vol% freezing point-37°C
OtherBattery charging rate (constant)6.0Ainitial battery charge
OtherBattery electrolyte specific gravity1.270 to 1.290at 20 degrees C (68 degrees F)
OtherBattery electrolyte specific gravity at charge completion1.27 to 1.29charge completed
OtherBattery electrolyte specific gravity when fully charged1.270 to 1.290at 20°C (68°F)
OtherBattery normal charging rate6.0A
OtherCompressed air pressure for cleaning air cleaner elementunder 205kPaat nozzle
OtherCoolant mixing ratio50/50%premix 50% LLC with 50% clean soft water
OtherFuel cetane number45 minimumgreater than 50 preferred below -20°C or above 1500 m
OtherGenerator power factor100%
OtherGlow plug continuous use limit20seconds
OtherPreheating time 10°C to -5°C (50°F to 23°F)Until glow lamp goes off
OtherPreheating time above 10°C (50°F)NO NEED
OtherPreheating time below -5°C (23°F)Approx. 5 seconds after the glow lamp goes offlimit of continuous use 20 seconds
OtherStarter motor continuous running limit10secondsif engine fails to start, wait about 30 seconds and try again
PressureCompressed air for air cleaner element cleaningunder 205kPaair pressure at nozzle
PressureCompression pressure2.84 to 3.24MPaat 3.3 to 5.0 1/s (200 to 300 rpm) with starter
PressureCompression pressure allowable limit2.26MPa
PressureEngine oil pressure at idle speedMore than 49kPaidle speed
PressureEngine oil pressure at rated speed196 to 441kParated speed
PressureEngine oil pressure drop warning lamp activation68.7 to 127.5kPa
PressureEngine oil pressure drop warning lamp set point68.7 to 127.5kPa (0.7 to 1.3 kgf/cm2)lamp flashes on below this oil pressure
PressureEngine oil pressure drop warning lamp threshold68.7 to 127.5kPaeasy checker lamp flashes on below this
PressureEngine oil pressure warning lamp threshold68.7 to 127.5kPalamp flashes on below this oil pressure
PressureFuel injection pressure13.73 to 14.71MPa
PressureFuel tightness of delivery valve10 secondss13.73 to 12.75 MPa (140 to 130 kgf/cm2)
PressureFuel tightness of delivery valve10 seconds (13.73 to 12.75 MPa)sfactory spec
PressureFuel tightness of pump element (allowable limit)13.7MPa
PressureFuel tightness of pump element (allowable limit)13.73MPa
PressureNozzle valve seat tightnessNo fuel leak at 12.75MPahold 10 seconds
PressureNozzle valve seat tightnessNo fuel leak at 12.75 MPa (130 kgf/cm2, 1849 psi)MPakept for 10 seconds
PressureOil pressure drop warning threshold68.7 to 127.5kPa (0.7 to 1.3 kgf/cm2)warning lamp flashes below this pressure
PressureRadiator cap pressure falling time10 seconds or more (88 to 59 kPa)s
PressureRadiator cap pressure falling timeMore than 10 secondss88 to 59 kPa (0.9 to 0.6 kgf/cm2, 13 to 9 psi)
PressureRadiator water leakage test pressure157kPa
ResistanceGlow plug resistanceApprox. 0.9ohm

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 ethylene glycol long-life coolant (LLC) and clean soft waterSAE J1034 / SAE J814c3.7 LKubota genuine LLC has 2-year service life
Coolant50/50 mix of long-life coolant (ethylene glycol type) and clean soft waterSAE J1034 / SAE J814c3.7 LIncluding reserve tank 0.6 L; change every 2 years; flush radiator with fresh water before use
CoolantClean water (soft water) with antifreeze 50/50Permanent type (PT) antifreeze; refer to SAE J1034 / SAE J814c; 40 vol% freezing point -24 °C, 50 vol% -37 °C3.7 LAntifreeze mixing ratio must be less than 50 %
CoolantClean water (soft water), antifreeze 50/503.7 LGL6000, GL7000; anti-freeze mixing ratio less than 50 %
CoolantEthylene glycol (EG) type long-life coolant, 50/50 mix with clean soft waterSAE J1034; SAE J814c3.7 LGL6000/GL7000 (Z482); 3.7 L (3.9 U.S.qts.), include reserve tank 0.6 L (0.63 U.S.qts.); change every 2 years
CoolantLong-life coolant (LLC), ethylene glycol type, 50/50 with clean soft waterSAE J1034 / SAE J814c3.7 LGL6000, GL7000 (Z482); change every 2 years; includes reserve tank 0.6 L; GL9000/GL11000 (D722) = 4.1 L
CoolantPure water and anti-freeze0.6 Lreserve tank volume; all seasons
Engine oilAPI classification CF, CF-4, CG-4, CH-4 or CI-4 with ultra low sulfur fuel; CF with high sulfur fuel2.2 LGL6000/GL7000 (engine Z482); 2.2 L (2.3 U.S.qts.)
Engine oil10W-30 or 10W-40API CF or higherbelow 10°Cbelow -10C
Engine oil10W-30 or 10W-40 or 15W-40API CF or higher / MIL-L-2104Cabove 25C use 10W-30/10W-40/15W-40
Engine oilAPI service class CF or higherMIL-L-2104C2.2 LChange oil type according to ambient temperature
Engine oilCFHigh Sulfur Fuel [>0.05% (500 ppm)]Other than North American market; halve intervals if CF-4/CG-4/CH-4/CI-4 used with high-sulfur fuel
Engine oilCF, CF-4, CG-4, CH-4 or CI-4Ultra Low Sulfur Fuel [<0.0015% (15 ppm)]North American market; CJ-4 intended for DPF type engines
Engine oilCF-4, CG-4, CH-4 or CI-4Low Sulfur Fuel [<0.05% (500 ppm)] or Ultra Low Sulfur Fuel [<0.0015% (15 ppm)]Other than North American market
Engine oilSAE 10W-30 or 10W-40API service class CF or higher (MIL-L-2104C)below -10°Cbelow -10°C (14°F); oil viscosity higher than 10W-30 not allowed
Engine oilSAE10W or SAE10W-30/10W-40API CD or higherbelow 0°CBelow 0°C (32°F)
Engine oilSAE10W-30below -10°CBelow -10 degrees C (14 degrees F)
Engine oilSAE10W-30, SAE10W-40, SAE10Higher than CD class (API)below 0°CBelow 0 °C (32 °F)
Engine oilSAE10W-30, SAE30 (above 25 °C); SAE10W-30, SAE10W-40, SAE20 (0 to 25 °C); SAE10W-30, SAE10W-40, SAE10 (below 0 °C)API classification higher than CF; CF, CF-4, CG-4, CH-4 or CI-4 for low/ultra low sulfur fuel; CF or CI-4 for internal/external EGR engines2.2 LMinimum TBN of 10 recommended with high sulfur fuel; change oil at approximately half intervals with high-sulfur fuel
Engine oilSAE10W-30 or SAE15W-40-10°C to 25°C-10 to 25 degrees C (14 to 77 degrees F)
Engine oilSAE10W-30, SAE10W-40, SAE20Higher than CD class (API)0°C to 25°C0 to 25 °C (32 to 77 °F)
Engine oilSAE20 or SAE10W-30/10W-40API CD or higher0°C to 25°C0 to 25°C (32 to 77°F)
Engine oilSAE 10W-30 or 10W-40 or 15W-40API service class CF or higher (MIL-L-2104C)above 25°Cabove 25°C (77°F)
Engine oilSAE10W-30, SAE30Higher than CD class (API)above 25°CAbove 25 °C (77 °F)
Engine oilSAE30 or SAE10W-30 or SAE15W-40API classification CF or higher; MIL-L-2104Cabove 25°CAbove 25°C (77°F)
Engine oilSAE30 or SAE10W-30, SAE15W-40above 25°CAbove 25 degrees C (77 degrees F)
Engine oilSAE30 or SAE10W-30/10W-40API CD or higherabove 25°CAbove 25°C (77°F)
Engine oilSAE30 or SAE10W-30; SAE15W-40API classification CF or higher; MIL-L-2104Cabove 25°CAbove 25°C (77°F)
FuelDiesel fuel No. 2 (ASTM D975)ASTM D975 / EN 59028.0 LCetane number 45 min (50+ preferred below -20C or above 1500m); ultra low sulfur (<15ppm) required in EPA regulated areas
FuelDiesel fuel No.2-DASTM D975; EN 590Cetane number 45 minimum (>50 preferred below -20°C or above 1500 m); below 0°C a mix of No.1-D and No.2-D is acceptable; No.2-D S15 in EPA regulated area

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting Fan Belt Tension adjustment

⚠ Be sure to stop the engine and remove the key before checking the belt tension.

⚠ Be sure to reinstall the detached safety shield after maintenance or checking.

  1. Stop the engine and remove the key.
  2. Apply moderate thumb pressure to belt between pulleys.
  3. If tension is not as specified, loosen the lock nut and turn the adjust nut to get belt tension within range.
  4. Tighten up the lock nut.
  5. Replace fan belt if it is damaged.
Adjusting Valve Clearance adjustment

⚠ Valve clearance must be checked and adjusted when engine is cold.

Tools: Feeler gauge

  1. Remove the head cover, the glow plugs and the timing window cover.
  2. Align the 1TC mark line on the flywheel with center of timing window for No. 1 piston.
  3. Check valve clearance with a feeler gauge.
  4. Adjust with the adjusting screw if not within factory specification.
  5. Turn flywheel 6.28 rad (360°) and adjust all other valve clearances.
  6. Recheck clearance and firmly tighten the lock nut.
Checking Fan Belt Tension adjustment

Tools: Belt tension gauge

  1. Measure the deflection by depressing the belt halfway between the fan drive pulley and alternator pulley.
  2. Loosen the alternator mounting screws if not within specification.
  3. Relocate the alternator to adjust.
Checking and Adjusting Valve Clearance adjustment

⚠ Valve clearance must be checked and adjusted when engine is cold.

Tools: Feeler gauge

  1. Remove head cover, glow plugs and timing window cover on flywheel housing.
  2. Align 1TC mark line on flywheel with center of timing window for No.1 TDC.
  3. Check valve clearance with a feeler gauge.
  4. If out of specification, adjust with adjusting screw.
Checking Fuel Injection Pressure diagnostic

⚠ Check after making sure nobody stands in the direction the fume goes.

Tools: Nozzle tester

  1. Set the injection nozzle to a nozzle tester.
  2. Slowly move the tester handle to measure pressure at which fuel begins jetting out.
  3. Replace the adjusting washer in the nozzle holder to adjust if out of specification.
Connecting the load (terminal output model) installation

⚠ Connect or disconnect load only when engine is stopped

  1. Turn OFF the circuit breaker on the control panel.
  2. Connect the load to the A.C. output terminals.
  3. Close the terminal cover after connecting the load.
  4. Secure the cover with the lock bolts.
Air bleeding the fuel system maintenance

⚠ Do not bleed a hot engine as this could cause fuel to spill onto a hot exhaust manifold creating a danger of fire.

  1. Fill the fuel tank to the fullest extent. Open the fuel filter cock.
  2. Loosen air vent plug of the fuel filter a few turns.
  3. Screw back the plug when bubbles do not come up any more.
  4. Open the air vent plug on top of the fuel injection pump.
  5. Retighten the plug when bubbles do not come up any more.
Battery charging maintenance

⚠ The batteries come in two types: refillable and non-refillable. Do not use or charge a refillable battery if the fluid level is below the LOWER mark.

Tools: Charger, Voltmeter or hydrometer

  1. Make sure each electrolyte level is to the bottom of vent wells; add only distilled water if necessary.
  2. To slow charge, connect the charger positive terminal to the battery positive terminal and the negative to the negative.
  3. Recharge the battery as early as possible, or battery life will be extremely shortened.
  4. When exchanging an old battery for a new one, use a battery of equal specifications.
Changing Battery maintenance

⚠ Stop engine before disconnecting cables; disconnect negative first, connect positive first.

  1. Open the generator door.
  2. Disconnect the cable from battery negative terminal.
  3. Disconnect the cable from battery positive terminal.
  4. Remove the battery.
  5. Install the new battery.
Changing Coolant maintenance

⚠ DO NOT remove the radiator cap while coolant is hot.

⚠ Work only after letting the engine and radiator cool off completely (more than 30 minutes after stopped).

  1. To drain coolant, always remove both drain plugs and simultaneously open the radiator cap.
  2. Remove the overflow pipe of the radiator pressure cap to drain the reserve tank.
  3. Prescribed coolant volume includes reserve tank 0.6 L (0.63 U.S.qts.).
  4. Fill with clean, fresh water and 50% anti-freeze.
Changing Coolant (L.L.C.) maintenance

⚠ Do not remove the radiator cap when the engine is hot.

  1. Stop the engine and let cool down.
  2. Open the water drain plug and remove radiator cap to drain the coolant.
  3. Close the water drain plug.
  4. Fill with clean water and anti-freeze until coolant level is just below the port.
  5. Fill with coolant up to FULL mark on the recovery tank.
  6. Start and operate the engine for few minutes, stop and let cool.
  7. Check coolant level of recovery tank and add coolant if necessary.
Changing Engine Oil maintenance

⚠ Be sure to stop the engine before draining engine oil.

⚠ DO NOT drain oil from a hot engine. Allow engine to cool down sufficiently to avoid being burned.

  1. Change oil after the initial 50 hours of operation and every 100 hours thereafter.
  2. Remove the drain plug to drain the engine oil; drain completely while warm.
  3. Inspect drain plug gasket. Replace if damaged.
  4. Install the oil drain plug and gasket.
  5. Add new engine oil up to the upper line of the oil level gauge.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
110 / 220 V1 - 4GL7000-STD, 60 HzMain coil R - W 0.25 ohm; BR - L 0.25 ohmNFB capacity 29.5 A
110/2201Main coilR - W; BR - LGL7000-STD; 0.25 Ω each
110/2201Single phase 3 terminals type (1P4W type) dual voltageGL7000-STD, 60 Hz
120 / 240 V1 - 3GL11000-USA, GL11000-USA-TM, 60 HzMain coil 1 - 3: 0.23 ohm; 1 - 2 and 2 - 3: 0.12 ohm; sub coil LG - LG 1.68 ohm; rotor coil 55.5 ohmNFB capacity 42 A; GL11000-STD (110/220 V) main coil 0.19 / 0.10 / 0.10 ohm, sub coil 1.73 ohm, NFB 45.5 A
120 / 240 V1 - 4GL7000-USA, GL7000-USA-TM, 60 HzMain coil R - W 0.28 ohm; BR - L 0.28 ohmNFB capacity 27.5 A
120/2401Main coilR - W; BR - LGL7000-USA; 0.28 Ω each
120/2401Receptacle outputGL7000-USA, GL11000-USA, 60 Hz
120/2401Single phase 3 terminals type (1P4W type) dual voltageGL7000-USA-TM, 60 Hz
2201Main coilR - WGL6000-STD; 0.55 Ω
2201Single phase 2 terminals typeGL6000-STD, GL9000-STD, 50 Hz
220 V1 - 2GL6000-STD, 50 HzMain coil R - W: 0.55 ohmSub coil G - LG/R 1.08 ohm; sub coil (DC) L/W - L/W 0.11 ohm; detecting coil LG - L 0.05 ohm; rotor coil 59.5 ohm
220 V1 - 3GL9000-STD, 50 HzMain coil 1 - 3: 0.28 ohm; sub coil LG - LG 1.96 ohm; detecting coil R - R 0.04 ohm; rotor coil 55.5 ohmNFB capacity 36.5 A; 240 V (GL9000-AUS) 0.34 ohm, NFB 33.5 A
2401Main coilR - WGL6000-AUS; 0.62 Ω
2401Receptacle outputGL6000-AUS, GL9000-AUS, 50 Hz
240 V1 - 2GL6000-AUS, 50 HzMain coil R - W: 0.62 ohmNFB capacity 23 A

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Kubota GL 11000?

The Kubota GL 11000 is rated 12 kW standby.

What engine does the Kubota GL 11000 use?

The Kubota GL 11000 is powered by the Kubota D722 engine.

Is the Kubota GL 11000 diesel or gas?

The Kubota GL 11000 runs on Diesel.

How much oil does the Kubota GL 11000 take?

The Kubota D722 engine in the Kubota GL 11000 has an oil capacity of 3.4 liters.

What is the coolant capacity of the Kubota GL 11000?

The Kubota GL 11000 cooling system holds 4.1 liters (1.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the sound level of the Kubota GL 11000?

The Kubota GL 11000 is rated at 68.0 dBA at 7 m, per the manufacturer specification sheet.

How much does the Kubota GL 11000 weigh?

The Kubota GL 11000 has a dry weight of 295 kg (650 lb).

What size fuel tank does the Kubota GL 11000 have?

The Kubota GL 11000 has a 28 liter (7 US gallon) fuel tank, giving about 7.0 hours of runtime.

What voltages is the Kubota GL 11000 available in?

The Kubota GL 11000 is offered in 110/220 V, 120/240 V, 1-phase.

What size battery does the Kubota GL 11000 need?

The Kubota GL 11000 uses 1 battery, 12 V each, group 55B24R, per the manufacturer specification sheet.

Which oil filter part number does the Kubota GL 11000 take?

The Kubota GL 11000 uses oil filter part number G3102-8841-0.

What fuel filter does the Kubota GL 11000 use?

The Kubota GL 11000 uses fuel filter part number G3102-8838-0.

What air filter does the Kubota GL 11000 use?

The Kubota GL 11000 uses air filter part number G3102-8839-0.

Troubleshooting

1

Symptoms & remedies

SymptomCauseRemedy
Generator does not start or runs poorly.Faulty spark plug, dirty air filter, clogged fuel line, low fuel level, faulty ignition system, or incorrect engine oil level.Check and replace the spark plug if necessary. Clean or replace the air filter. Clear any blockages in the fuel line. Refuel with fresh fuel. Check and adjust the ignition system as needed. Ensure the correct amount of engine oil is present.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

27
Part #DescriptionQtySystem
07909-30241PlastigagePlastigage Amazon eBay
07909-31371Red CheckRed check Amazon eBay
07909-31661Connecting Rod Alignment ToolConnecting rod alignment tool Amazon eBay
07909-33102Valve Seat CutterValve seat cutter Amazon eBay
07916-09032Special Use Puller SetSpecial use puller set Amazon eBay
07916-32011Flywheel PullerFlywheel puller Amazon eBay
07916-32032Oil Pressure TesterOil pressure tester Amazon eBay
07916-34041Auxilary Socket for Fixing Crankshaft SleeveAuxiliary socket for fixing crankshaft sleeve Amazon eBay
1T021-43560Fuel FilterFuel filter Amazon eBay $9.25 KuduParts $8.00 FridayParts $8.19
32721-58242Air Filter InnerAir filter Amazon eBay $34.95 KuduParts $13.00 FridayParts $15.50 SinoCMP $69.00
6C060-99410Air Filter OuterAir filter Amazon eBay $37.24 KuduParts $21.00 FridayParts $22.74 SinoCMP $69.00
G3102-8830-0Gasket1Gasket Amazon eBay
G3102-8831-0Coolant filter1Coolant filter Amazon eBay
G3102-8832-0V-belt1Belt Amazon eBay
G3102-8833-0Battery1Battery Amazon eBay
G3102-8836-0Spark plug1Spark plug Amazon eBay
G3102-8838-0Fuel filter1Fuel filter Amazon eBay
G3102-8839-0Air cleaner1Air filter Amazon eBay
G3102-8841-0Oil filter cartridge1Oil filter Amazon eBay
GL6000Fuel filter cartridge or elementFuel filter Amazon eBay $372.35 FridayParts $22.74
GL9000Fuel filter cartridge or elementFuel filter Amazon eBay FridayParts $15.80
HH150-32094OIL FILTEROil filter Amazon eBay $19.99 NAPA $9.64 KuduParts $17.00 FridayParts $18.90
HH150-32430OIL FILTEROil filter Amazon Amazon eBay $39.49 eBay $17.99 NAPA $9.64 KuduParts $11.00 FridayParts $13.16
W10252400Injection Pump Pressure TesterInjection pump pressure tester Amazon eBay
W1040289Idle Gear Bushing Replacing ToolIdle gear bushing replacing tool Amazon eBay
W1062553Connecting Rod Small End Bushing ToolConnecting rod small end bushing tool Amazon eBay
W1046346Brush length (Stretch out of the Holder)1Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
100%2.40.63
1/2 load50%2.70.71
1/4 load25%2.20.59
100% load100%2.60.69
25% load25%2.50.66
3/4 load75%3.30.86
50% load50%3.20.85
75% load75%3.91.03
Full load100%4.11.09

Available documents

Spec sheet — 9844 GL11000 specs (Kubota)Spec sheet — GLSeries (Kubota)Operator's manual — 59890 (Kubota)Operator's manual — Kubota-GL9000-Operators-Manual (Kubota)Reference — 59227 Kubota Generator Bro-Web-SinglePgs (Kubota)Reference — 74830 Kubota 2021 GL Maintenance Kit SellSheet LR (Kubota)Reference — Kubota Generator-Full-Line HR (Kubota)Reference — Kubota Parts GL Maintenance Kit Oil EN HR (Kubota)Owner's manual — 2950 gl7000 operatorsm (Kubota)Owner's manual — 635adac789d0116565862577 Kubota GL11000 Operators Manual (Kubota)Owner's manual — GEN 1 PH 6 KVA D Kubota GL 6000 GL 6000 D Operation Manual pdf 3421faafee (Kubota)Owner's manual — GL-Series-GL-7000-GL11000-Operators-Manual (Kubota)Owner's manual — Kubota LowBoy II Diesel Generator GL7000-CAN GL11000-CAN Canada Series - Owners Manual (Kubota)Owner's manual — Kubota LowBoy II Diesel Generator GL7000 GL11000 GL Series - Operators Manual (Kubota)Owner's manual — Tech-Manual-Final-V3 (DC SOLAR Distribution)Parts manual — Kubota Parts GL Maintenance Kit HR-2 (Kubota)Parts manual — Kubota Parts OilFilter EN HR (Kubota)Parts manual — Kubota Parts Oil OilFilter EN HR (Kubota)Parts manual — Kubota Parts Oil OilFilter HR (Kubota)Service manual — 635adac789d0113e87862586 Kubota GL-Series Service Manual (Kubota)Service manual — Kubota LowBoy II Diesel Generator GL7000 GL11000 GL Series - Service Manual (Kubota)

This page was generated from the 21 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.