Home›Repair guides›Kohler›Starting Generator Set

Kohler — Starting Generator Set

Operation · Generator set / ADC-RES

From a Kohler operator's manual covering: 12RES, 12TRES, 17/18RES, 18TRES, 8.5RES. Check it applies to your exact model before use.

Applies to: Kohler 12RES, Kohler 12TRES, Kohler 18TRES, Kohler 8.5RES, Kohler CH640 engine, Kohler CH 740 engine, Kohler CH 980 engine

Procedure

  1. For local start, move generator set master switch to RUN to immediately start the generator set.
  2. For automatic start, move master switch to AUTO and close a contact across engine start leads 3 and 4.
  3. If the engine does not start in three crank attempts, the system shuts down on overcrank.

Specs & values

  • Crank cycle: three attempts of 15 seconds crank and 15 seconds off

Full service-parts list: Kohler 12RES →, Kohler 12TRES →, Kohler 18TRES →, Kohler 8.5RES →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.