Home›Repair guides›Kohler›Speed Sensor Test with Separate 12 VDC Source

Kohler — Speed Sensor Test with Separate 12 VDC Source

Testing & diagnosis

From a Kohler service manual covering: 125REOZJG, 150 REOZJ4, 150REZG, 175REOZT4, 2000REOZM, 2000REOZMD, 2250REOZDD, 275REOZJD, 275REOZJE, 400REZX, 400RZX, 48REOZK4…. Check it applies to your exact model before use.

Applies to: Kohler 125REOZJG, Kohler 150 REOZJ4, Kohler 150REZG, Kohler 175REOZT4, Kohler 2000REOZM, Kohler 2000REOZMD, Kohler 2250REOZDD, Kohler 275REOZJD, Kohler 275REOZJE, Kohler 400REZX, Kohler 400RZX, Kohler 48REOZK4

Procedure

  1. Place master switch in OFF/RESET position.
  2. Disconnect the speed sensor leads.
  3. Connect speed sensor, DC voltmeter, and DC voltage source as shown.
  4. Touch sensing surface with a flat piece of iron or steel at least 4.1 cm (1/4 cu. in.) in size.
  5. DC voltmeter reading should equal the source voltage, approximately 12 VDC.
  6. Remove the iron or steel piece and observe a voltmeter reading of 0 VDC.
  7. If the sensor passes, it is functional; replace if it fails.
  8. Connect the speed sensor leads and adjust the air gap.

Tools required

  • DC voltmeter Amazon
  • 12-volt battery or DC power supply Amazon
  • Flat piece of iron or steel Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Speed sensor air gap 0.36- 0.71 mm (0.014- 0.028 in.)

Full service-parts list: Kohler 125REOZJG →, Kohler 150 REOZJ4 →, Kohler 175REOZT4 →, Kohler 2000REOZM →, Kohler 2000REOZMD →, Kohler 2250REOZDD →, Kohler 275REOZJD →, Kohler 275REOZJE →, Kohler 48REOZK4 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.