Kohler — Extended Storage (Lubricating System)
Maintenance · Engine lubricating system
From a Kohler operator's manual covering: 125REZGT, 30--125REZGT, 30REZG, 30REZGT, 50REZG, 70REZGT. Check it applies to your exact model before use.
Applies to: Kohler 125REZGT, Kohler 30REZG, Kohler 30REZGT, Kohler 50REZG, Kohler 70REZGT
Before you start
- Hot engine and exhaust system. Do not work on the generator set until it cools.
Procedure
- Run the generator set for a minimum of 30 minutes to bring it to normal operating temperature.
- Stop the generator set.
- With the engine still warm, drain the oil from the crankcase.
- Remove and replace the oil filter.
- Refill the crankcase with oil suited to the climate.
- Run the generator set for two minutes to distribute the clean oil.
- Stop the generator set.
- Check the oil level and adjust, if needed.
Specs & values
- Perform before taking out of service for three months or longer
Full service-parts list: Kohler 125REZGT →, Kohler 30REZG →, Kohler 30REZGT →, Kohler 50REZG →, Kohler 70REZGT →
Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.