Kohler — Exercising Generator Set

Operation

From a Kohler operator's manual covering: 12RES, 12TRES, 17RES, 18RES, 18TRES, 8.5/12 RES, 8.5RES. Check it applies to your exact model before use.

Applies to: Kohler 12RES, Kohler 12TRES, Kohler 17RES, Kohler 18RES, Kohler 18TRES, Kohler 8.5RES, Kohler CH640 engine, Kohler CH 740 engine, Kohler CH 980 engine

Before you start

  • Exercise the unit in the presence of an operator if not connected to an ATS with an exercise option.

Procedure

  1. Operate the generator set without load once each week for 20 minutes.
  2. Perform all prestart checks before starting the exercise procedure.
  3. Start the generator set according to the starting procedure in the controller section.
  4. Listen for a smooth-running engine and visually inspect for fluid or exhaust leaks.
  5. Check the air inlets and outlets and remove any items restricting the air flow.

Full service-parts list: Kohler 12RES →, Kohler 12TRES →, Kohler 17RES →, Kohler 18RES →, Kohler 18TRES →, Kohler 8.5RES →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.