Procedure
- Perform enclosure/panel removal steps 1-12.
- Remove six air in duct base panel bolts and remove air in duct base.
- Remove four standoff bolts from top of stator.
- Disconnect Wire 4 and Wire 0 from brush holder assembly.
- Remove two brush holder screws and remove brush holder assembly.
- Remove Wire 11 and Wire 33 from circuit breaker.
- Remove Wire 66 and Wire 77 from Battery Charge Rectifier.
- Remove Wire 55 from R1 resistor.
- Remove Wire 11, Wire 22 and Wire 6 from Voltage Regulator.
- Remove Wire 2 from DPE circuit breaker.
- Remove Wire 22 and Wire 44 from ground lug.
- Remove upper bearing carrier.
- Remove stator.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Full service-parts list: Generac QUIETPACT 55 →, Generac QuietPact 65 →, Generac QuietPact 75 →
Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.