Generac IQ3500 — Return to Service
Installation · Generator
For the Generac IQ3500, from the Generac owner's manual.
Applies to: Generac IQ3500, Generac GH-410 engine, Generac GT-530 engine, Generac GT-530 engine, Generac GT-990 engine, Generac GT-999 engine
Before you start
- The exercise timer and current date and time must be reset when the battery is dead or has been disconnected.
Procedure
- Verify that utility power is turned off.
- Check the tag on the engine for oil viscosity and classification; drain and refill if necessary.
- Check the state of the battery; fill unsealed batteries to proper level with distilled water; recharge to 100%.
- Clean and wipe down the entire generator.
- Make sure the 7.5 Amp fuse is removed from the generator Control Panel.
- Reconnect the battery. Observe battery polarity. Install positive cable first.
- Reconnect the battery charger AC input T1/Neutral cable (white sleeve) at controller.
- Open the fuel shutoff valve.
- Insert the 7.5 Amp fuse into the generator Control Panel.
- Start the unit by pressing the MANUAL button. Allow the unit to warm up for a few minutes.
- Stop the unit by pressing the Control Panel OFF button.
- Turn on the utility power to the transfer switch.
- Set the Control Panel to AUTO.