For the Generac IQ3500, from the Generac owner's manual.

Applies to: Generac IQ3500, Generac GH-410 engine, Generac GT-530 engine, Generac GT-530 engine, Generac GT-990 engine, Generac GT-999 engine

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.
  3. Set the generator's Main Circuit Breaker (Generator Disconnect) to its OFF (OPEN) position.
  4. Turn off the utility power to the transfer switch.
  5. Remove the 7.5 Amp fuse from the generator's Control Panel.
  6. Disconnect the battery cables. Remove negative cable first.
  7. Remove battery charger AC input T1/Neutral cable (white sleeve) at controller.
  8. While the engine is still warm, drain the oil completely, then refill the crankcase with oil.
  9. Attach a tag to the engine indicating viscosity and classification of the new oil.
  10. Remove spark plug(s), spray a fogging agent into the threaded openings, reinstall and tighten.
  11. Remove the battery and store it in a cool, dry room on a wooden board.
  12. Clean and wipe down the entire generator.

Full service-parts list: Generac IQ3500 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.