Home›Repair guides›Generac›Remove From Service (Storage over 90 days)

Generac G0070420 — Remove From Service (Storage over 90 days)

Maintenance · Generator

For the Generac G0070420, from the Generac owner's manual.

Applies to: Generac G0070420, Generac GH-426 engine, Generac GTH-530 engine, Generac GT-999 engine

Before you start

  • Explosion. Batteries emit explosive gases. Always disconnect negative battery cable first to avoid spark.

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and allow engine to stop.
  3. Set generator MLCB (generator disconnect) to OFF (OPEN).
  4. Turn off the utility power to the transfer switch.
  5. Remove battery charger AC input T1/Neutral cable (white sleeve) at controller.
  6. Remove the 7.5 amp fuse from the generator control panel.
  7. Disconnect battery cables; remove negative cable first.
  8. Drain oil completely while engine is still warm, then refill crankcase with oil.
  9. Attach a tag to the engine indicating viscosity and classification of new oil.
  10. Remove spark plug(s) and spray fogging agent into threaded openings; reinstall and tighten to specification.
  11. Remove battery and store in cool, dry room on a wooden board.
  12. Clean and wipe down the entire generator.

Full service-parts list: Generac G0070420 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.