Generac G-Force 1000 Series — Cleaning the Sediment Trap

Maintenance

For the Generac G-Force 1000 Series, from the Generac owner's manual.

Applies to: Generac G-Force 400 Series engine, Generac G-Force 800 Series engine, Generac G-Force 1000 Series engine

Before you start

  • Explosion and fire. No leakage of fuel is permitted. Keep fire and spark away.

Procedure

  1. Remove intake side panel.
  2. Turn generator fuel supply OFF.
  3. Unscrew and remove cap.
  4. Use a clean-out tool to remove accumulated moisture and particles from cap and body.
  5. Wipe inside of each component with a clean, dry, lint-free cloth.
  6. Seal threads of cap with appropriate sealing compound; install cap and hand-tighten.
  7. Tighten cap with an appropriately sized pipe wrench; do not overtighten.
  8. Turn generator fuel supply ON and leak test all connection points with non-corrosive gas leak detection fluid.
  9. Install intake side panel.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.