Home›Repair guides›Generac›Check/Install Crankcase Breather

Generac — Check/Install Crankcase Breather

Maintenance

From a Generac service manual covering: QUIETPACT 55, QuietPact 65, QuietPact 75. Check it applies to your exact model before use.

Applies to: Generac QUIETPACT 55, Generac QuietPact 65, Generac QuietPact 75, Generac GTV-760 engine

Procedure

  1. Disconnect breather tube and remove four screws and breather; discard gasket.
  2. Check that reed valve is not deformed and forms complete seal around vent hole.
  3. Remove oil vapor collector and retainer; check collector for deterioration, replace if necessary.
  4. Install oil vapor collector and retainer, pushed in until it bottoms.
  5. Install breather with new gasket, torque screws to 5-8 ft-lbs.
  6. Assemble breather tube to intake elbow.

Specs & values

  • Torque screws to 5-8 ft-lbs

Full service-parts list: Generac QUIETPACT 55 →, Generac QuietPact 65 →, Generac QuietPact 75 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.