Home›Repair guides›Generac›Adjust Choke Solenoid

Generac — Adjust Choke Solenoid

Adjustments · Choke assembly

From a Generac service manual covering: QUIETPACT 55, QuietPact 65, QuietPact 75. Check it applies to your exact model before use.

Applies to: Generac QUIETPACT 55, Generac QuietPact 65, Generac QuietPact 75, Generac GTV-760 engine

Procedure

  1. Loosen screws retaining choke solenoid to its bracket.
  2. Slide choke solenoid in slotted holes to adjust axial movement of solenoid plunger.
  3. Adjust until, with choke plate closed, solenoid is bottomed in its coil.
  4. Tighten the two screws; verify plunger and linkage move freely.

Specs & values

  • Choke plate approximately 1/8 inch from full open position when solenoid not actuated

Full service-parts list: Generac QUIETPACT 55 →, Generac QuietPact 65 →, Generac QuietPact 75 →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Generac repair guides →