For the Generac 8.1 GN, from the Generac owner's manual.

Applies to: Generac 8.1 GN, Generac GH-410 engine, Generac GT-530 engine, Generac GT-990 engine, Generac GT-999 engine

Before you start

  • Damage may occur if the battery is connected incorrectly.

Procedure

  1. Verify that utility power is turned off.
  2. Check the tag on the engine for oil viscosity and classification; drain and refill with proper oil if necessary.
  3. Check the battery state; fill unsealed cells with distilled water and recharge to 100%. Replace if defective.
  4. Clean and wipe down the entire generator.
  5. Make sure the 7.5 Amp ATO fuse is removed from the Control Panel.
  6. Reconnect the battery, observing polarity; install positive cable first.
  7. Reconnect the battery charger AC input T1/Neutral cable (white sleeve) at controller.
  8. Open the fuel shutoff valve.
  9. Insert the 7.5 Amp ATO fuse into the Control Panel.
  10. Start the unit by pressing the MANUAL button and allow to warm up.
  11. Stop the unit by pressing the Control Panel OFF button.
  12. Turn on the utility power to the transfer switch.
  13. Set the Control Panel to AUTO.

Full service-parts list: Generac 8.1 GN →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.