Fischer Panda — Replacement of the impeller
Maintenance · Raw water pump impeller
From a Fischer Panda owner's manual covering: Panda 4000S neo, Panda 4200 FC, Panda 5000i Neo, Panda 5000i PMS, Panda 5000i PMS generator, Panda 5000i.Neo, Panda 5000i.Neo PMS, Panda PMGi 5000, Panda iControl2. Check it applies to your exact model before use.
Applies to: Fischer Panda Panda 5000i PMS generator, Fischer Panda Panda 5000i.Neo, Fischer Panda Panda 5000i.Neo PMS, Fischer Panda FPE-320 engine
Procedure
- Close raw water stop cock.
- Remove cover of raw water pump by loosening wing screws.
- Pull impeller with multigrip pliers from shaft; mark position.
- Check impeller for damage and replace if necessary.
- Lubricate impeller with glycerin or non-mineral oil based lubricant.
- Attach impeller to pump shaft; observe marking.
- Fasten cover and use a new seal.
Tools required
- Multigrip pliers Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Full service-parts list: Fischer Panda Panda 5000i PMS generator →, Fischer Panda Panda 5000i.Neo →
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.