Fischer Panda Panda 4K PMS / Panda 5K PMS — Insulation test
Installation · AC electrical system
For the Fischer Panda Panda 4K PMS / Panda 5K PMS, from the Fischer Panda owner's manual.
Applies to: Fischer Panda Panda 4K PMS, Fischer Panda Panda 5K PMS, Kubota Z482 engine, Kubota EA300 engine
Procedure
- Switch off all on-board electrical devices.
- Start generator.
- Measure AC voltage between generator housing and AC-Control box, and between generator housing and ground.
- Measured voltage must not exceed 50 mV.
- Check safety systems and RCD if installed.
- Check all electrical devices are connected to common ground.
Tools required
- voltmeter Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- measured voltage must not exceed 50 mV
Full service-parts list: Fischer Panda Panda 4K PMS →, Fischer Panda Panda 5K PMS →, Kubota Z482 engine →