Home›Repair guides›Cummins/Onan›Vibration Damper - Checking

Cummins/Onan — Vibration Damper - Checking

Maintenance

From a Cummins/Onan owner's manual covering: K1800, K2000E, K38, K50, KT38, KTA 50 G3, KTA-50G3, KTTA50, KtA38, KtA50, KttA38. Check it applies to your exact model before use.

Applies to: Cummins/Onan K38, Cummins/Onan K50, Cummins/Onan KTA-50G3, Cummins/Onan KTA38, Cummins/Onan KTA50

Before you start

  • Do not repair or balance a viscous damper in the field.

Procedure

  1. Clean the exterior of the damper with solvent.
  2. Inspect mounting flange for cracks.
  3. Inspect housing for dents, bulges, or leaks.
  4. Remove paint and measure thickness at four locations, 90 degrees apart.
  5. Replace damper if damaged or thickness exceeds specification.
  6. Replace damper after 24,000 hours regardless of measurement.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Houdaille max thickness 65.38 mm [2.574 in]
  • Readings must not vary more than 0.25 mm [0.010 in]

Full service-parts list: Cummins/Onan K38 →, Cummins/Onan K50 →, Cummins/Onan KTA-50G3 →, Cummins/Onan KTA38 →, Cummins/Onan KTA50 →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.