Cummins/Onan — Stopping

Operation · Control panel

From a Cummins/Onan operator's manual — check it applies to your exact model before use.

Applies to: Cummins/Onan GGHE, Cummins/Onan GGHF, Cummins/Onan Modified Ford V-10 WSG-1068 engine

Procedure

  1. Run the generator set at no load for three to five minutes before stopping.
  2. Move the Run/Stop/Remote switch or remote starting switch to the STOP position.
  3. If started by an automatic transfer switch, the transfer switch will send a remote (timed delay) stop signal after normal power returns.
  4. For emergency stop, push in the optional emergency stop button; to reset, pull switch out and move Run/Stop/Remote switch to Stop position, then push test switch to Reset/Lamp Test position.

Full service-parts list: Cummins/Onan GGHE →, Cummins/Onan GGHF →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.