Home›Repair guides›Cummins/Onan›Locking the Generator Set Out of Service

Cummins/Onan — Locking the Generator Set Out of Service

Maintenance

From a Cummins/Onan service manual covering: C25 D6, C30 D6, C35 D6, C40 D6, C50 D6, C60 D6. Check it applies to your exact model before use.

Applies to: Cummins/Onan C25 D6, Cummins/Onan C30 D6, Cummins/Onan C35 D6, Cummins/Onan C40 D6, Cummins/Onan C50 D6, Cummins/Onan C60 D6, Cummins/Onan 4BT3.3 engine, Cummins/Onan 4BT3.3-G5 engine, Cummins/Onan 4BT3.3-G7 engine

Before you start

  • Accidental or remote starting of the generator set can cause severe personal injury or death.

Procedure

  1. Press Off switch, then press E-Stop button.
  2. Thoroughly ventilate the generator set before disconnecting any leads.
  3. Turn off and disconnect the heater (where fitted) from AC source.
  4. Turn off and disconnect the battery charger (where fitted) from AC source.
  5. Turn off the fuel supply to the engine.
  6. Disconnect the battery negative cable first using an insulated wrench.
  7. Place warning notices at each location.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan C25 D6 →, Cummins/Onan C35 D6 →, Cummins/Onan C50 D6 →, Cummins/Onan C60 D6 →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.