Home›Repair guides›Cummins/Onan›Circuit Breaker Resistance Check

Cummins/Onan — Circuit Breaker Resistance Check

Testing & diagnosis · AC load circuit breaker

From a Cummins/Onan service manual covering: 4BT3.9, 4BT3.9-GC1, 4BT3.9-GC2, 6BT5.9, 6BT5.9-GC1, 6BT5.9-GC2, 6CT8.3, 6CT8.3-GS/GC1, 6CTA8.3, 6CTA8.3-GS/GC1, 6CTA8.3-GS/GC2. Check it applies to your exact model before use.

Applies to: Cummins/Onan 4BT3.9, Cummins/Onan 6BT5.9, Cummins/Onan 6CTA8.3, Cummins/Onan 4BT3.9 engine, Cummins/Onan 6BT5.9 engine, Cummins/Onan 6CT8.3 engine, Cummins/Onan 6CTA8.3 engine

Before you start

  • Place Run/Stop/Remote switch in Stop position and disconnect battery negative (-) cable.

Procedure

  1. Disconnect the line and load wires from the circuit breaker.
  2. Move breaker handle to On position and check resistance across each pole (line to load).
  3. Resistance should be very low (near zero) and relatively equal across all poles.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Resistance near zero and equal across all poles

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.